Nameplate capacity

Nameplate capacity

Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity or maximum effect, refers to the intended technical full–load sustained output of a facility such as a power plant,[1][2] a chemical plant,[3] fuel plant,[4][5][6] metal refinery,[7] mine,[8] and many others.

For dispatchable power, this capacity depends on the internal technical capability of the plant to maintain output for a reasonable amount of time (for example, a day), not momentarily or everlasting, and without considering external events such as lack of fuel or internal events such as maintenance.[9] Actual output can be different from nameplate capacity for a number of reasons depending on equipment and circumstances.[9][10]

Nameplate capacity is the number registered with authorities for classifying the power output of a power station usually expressed in MegaWatts (MW).[11]

Power plants with a high occurrence near nameplate capacity have a high capacity factor.

Diagram of a turbo-electric COGAS power-plant, with power-consuming pump

The term is connected with nameplates on electrical generators as these plates describing the model name and manufacturer usually also contain the rated output,[12] but the rated output of a power station to the electrical grid is usually less than the generator capacity because the components outside the generator, but inside the power station, also use power which detracts from the amount that reaches the grid. Thus there is a distinction between component capacity and facility capacity.

For non-dispatchable power, particularly renewable energy, nameplate capacity refers to generation under ideal conditions. Output is generally limited by weather conditions, hydroelectric dam water levels, tidal variations and other outside forces. Equipment failures and maintenance usually contribute less to capacity factor reduction than the innate variation of the power source.

See also

References

  1. ^ Energy glossary Energy Information Administration. Retrieved: 23 September 2010.
  2. ^ Glossary Nuclear Regulatory Commission, 2 August 2010. Retrieved: 23 September 2010.
  3. ^ Plant Performance Data (PPD) ICIS. Retrieved: 23 September 2010.
  4. ^ Refinery Economics Natural Resources Canada, 5 january 2009. Retrieved: 23 September 2010.
  5. ^ Magnificent seven Arabian Business, 17 June 2008. Retrieved: 23 September 2010.
  6. ^ Daniel O’Brien and Mike Woolverton. Trends in U.S. fuel ethanol production capacity: 2005-2009 K-State & Extension, August 2009. Retrieved: 23 September 2010.
  7. ^ Refining Capacity Alcoa, December 31, 2009 . Retrieved: 23 September 2010.
  8. ^ The Future of Tantalum and Niobium Mining-Technology, 14 Jan 2010. Retrieved: 23 September 2010.
  9. ^ a b Kleiser, Thomas. Response to CDM page 2-4 by TÜV, 4 March 2009. Retrieved: 23 September 2010.
  10. ^ Swain, Bibb. Designed to go above Nameplate Capacity Ethanol Producer, November 2006. Retrieved: 23 September 2010.
  11. ^ Certificate of Nameplate Capacity Ohio Department of Development. Retrieved: 23 September 2010.
  12. ^ Reitze, Arnold W. Air pollution control law: compliance and enforcement page 260 George Washington University Law School, 2001. ISBN 1585760277, 9781585760275 Retrieved: 23 September 2010.

Wikimedia Foundation. 2010.

Игры ⚽ Нужно решить контрольную?

Look at other dictionaries:

  • Generator nameplate capacity — (installed)   The maximum rated output of a generator, prime mover, or other electric power production equipment under specific conditions designated by the manufacturer. Installed generator nameplate capacity is commonly expressed in megawatts… …   Energy terms

  • Installed nameplate capacity —   See Generator nameplate capacity (installed).   U.S. Dept. of Energy, Energy Information Administration s Energy Glossary …   Energy terms

  • Capacity factor — The net capacity factor of a power plant is the ratio of the actual output of a power plant over a period of time and its output if it had operated at full nameplate capacity the entire time. To calculate the capacity factor, total the energy the …   Wikipedia

  • Capacity —   The load that a power generation unit or other electrical apparatus or heating unit is rated by the manufacture to be able to meet or supply.   The maximum load a generating unit, generating station, or other electrical apparatus is rated to… …   Energy terms

  • Maximum generator nameplate capacity —   The maximum rated output of a generator, prime mover, or other electric power production equipment under specific conditions designated by the manufacturer.   U.S. Dept. of Energy, Energy Information Administration s Energy Glossary …   Energy terms

  • Installed capacity —   The total generating units capacities in a power plant or on a total utility system. The capacity can be based on the nameplate rating or the net dependable capacity …   Energy terms

  • Intermittent power source — [ Erie Shores Wind Farm monthly output over a two year period] An intermittent power source is a source of electric power generation that may be uncontrollably variable or more intermittent than conventional power sources, and therefore non… …   Wikipedia

  • Wind power — Wind power: worldwide installed capacity [1] …   Wikipedia

  • Intermittent energy source — An intermittent energy source is any source of energy that is not continuously available due to some factor outside direct control. The intermittent source may be quite predictable, for example, tidal power, but cannot be dispatched to meet the… …   Wikipedia

  • Meadow Lake Wind Farm — View westward of Indiana Route 43 in White County …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”