An oropharyngeal airway (also known as an oral airway, OPA or Guedel pattern airway) is a medical device called an airway adjunct used to maintain a patent (open) airway. It does this by preventing the tongue from covering the epiglottis, which could prevent the person from breathing. When a person becomes unconscious, the muscles in their jaw relax and allow the tongue to obstruct the airway.[1]

Contents

History and usage

The oropharyngeal airway was designed by Arthur Guedel.[2]

Oropharyngeal airways come in a variety of sizes, from infant to adult, and are used commonly in pre-hospital emergency care and for short term airway management post anaesthetic or when manual methods are inadequate to maintain an open airway. This piece of equipment is utilized by certified first responders, emergency medical technicians, and paramedics - plus other health professionals when tracheal intubation is either not available, not advisable or the problem is of short term duration.

Oropharyngeal airways are indicated only in unconscious people, because of the likelihood that the device would stimulate a gag reflex in conscious or semi-conscious persons. This could result in vomit and potentially lead to an obstructed airway. Nasopharyngeal airways are mostly used instead as they do not stimulate a gag reflex. In general oropharyngeal airways need to be sized and inserted correctly to maximise effectiveness and minimise possible complications - such as oral trauma.

Insertion

OP airways in varying sizes

The correct size OPA is chosen by measuring from the middle of the persons mouth to the angle of the jaw. The airway is then inserted into the persons mouth upside down. Once contact is made with the back of the throat, the airway is rotated 180 degrees, allowing for easy insertion, and assuring that the tongue is secured. An alternative method for insertion, the method that is recommended for OPA use in children and infants, involves holding the tongue forward with a tongue depressor and inserting the airway right side up.[1]

The device is removed when the person regains swallow reflex and can protect their own airway. Simply remove by pulling on it without rotation.[1]

Usage

Use of an OPA does not remove the need for the recovery position and ongoing assessment of the airway and it does not prevent obstruction by liquids (blood, saliva, food, cerebrospinal fluid) or the closing of the glottis. But can facilitate ventilation during CPR (cardiopulmonary resuscitation) and for persons with a large tongue.

Key risks of use

The mains risks of its use are:[citation needed]

  • if the person has a gag-reflex they may vomit
  • when it is too large, it can close the glottis and thus close the airway
  • improper sizing can cause bleeding in the airway

See also

References

  1. ^ a b c Ed Dickinson; Dan Limmer; O'Keefe, Michael F.; Grant, Harvey D.; Bob Murray (2008). Emergency Care (11th Edition). Englewood Cliffs, N.J: Prentice Hall. pp. 157–9. ISBN 0-13-500524-8. 
  2. ^ Guedel A. E. J. Am. Med. Assoc. 1933, 100, 1862 (reprinted in “Classical File”, Survey of Anesthesiology 1966,10, 515)

External links


Wikimedia Foundation. 2010.

Игры ⚽ Поможем написать реферат

Look at other dictionaries:

  • oropharyngeal airway — n a tube used to provide free passage of air between the mouth and pharynx of an unconscious person * * * a curved tube designed to be placed in the mouth of an unconscious patient, behind the tongue, to create a patent airway. See also… …   Medical dictionary

  • oropharyngeal airway — a curved tube designed to be placed in the mouth of an unconscious patient, behind the tongue, to create a patent airway. See also: nasopharyngeal airway …   The new mediacal dictionary

  • Airway management — In cardiopulmonary resuscitation, anaesthesia, emergency medicine, intensive care medicine and first aid, airway management is the process of ensuring that: # there is an open pathway between a patient’s lungs and the outside world, and # the… …   Wikipedia

  • Airway (disambiguation) — The term airway may refer to the following medical terms: *Airway, a part of the respiratory system through which air flows *Nasopharyngeal airway, a tube used in the nasal passageway to secure an open airway *Oropharyngeal airway, a medical… …   Wikipedia

  • airway — n. 1) any of the passages of the respiratory system. 2) any device that enables the flow of air into and out of the lungs. See: nasopharyngeal airway, oropharyngeal airway …   The new mediacal dictionary

  • Oropharyngeal dysphagia — ICD 10 R13 ICD 9 787.22 DiseasesDB 17942 …   Wikipedia

  • Airway — The path air follows to get into and out of the lungs. The mouth and nose are the normal entry and exit ports. Entering air then passes through the back of the throat (pharynx), continues through the voice box (larynx), down the trachea, and… …   Medical dictionary

  • Nasopharyngeal airway — Intervention Nasopharyngeal airway. ICD 9 CM …   Wikipedia

  • nasopharyngeal airway — a curved tube to be slotted down one nostril of an unconscious patient, to sit behind the tongue, to create a patent airway. See also oropharyngeal airway. * * * a hollow tube inserted into a nostril and directed along the floor of the nose to… …   Medical dictionary

  • nasopharyngeal airway — a curved tube to be slotted down one nostril of an unconscious patient, to sit behind the tongue, to create a patent airway. See also: oropharyngeal airway …   The new mediacal dictionary

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”