- Software flow control
Software flow control is a method of
flow control used in computerdata link s, especially RS-232 serial. It uses special codes, transmitted in-band, over the primary communications channel. These codes are generally called XOFF and XON (from "transmit off" and "on", respectively). Thus, "software flow control" is sometimes called "XON/XOFF flow control". This is in contrast to flow control via dedicatedout-of-band signals — "hardware flow control" — such asRTS/CTS .Representation
For systems using the
ASCII character code, XOFF is generally represented using a character orbyte with value 19; XON with value 17.The ASCII standard does not specify any
control character s for use as XON/XOFF specifically. However, it does provide four generic "device control" characters (DC1 through DC4). The seminalASR-33 Teletype adopted two of these, DC3 and DC1, for use as XOFF and XON, respectively. This usage was copied by others, and is now a de facto standard. The keyboard equivalents of CTRL+S for XOFF, and CTRL+Q for XON, also derive from this usage.Mechanism
When one end of a data link is unable to accept any more data (or approaching that point), it sends XOFF to the other end. The other end receives the XOFF code, and suspends transmission. Once the first end is ready to accept data again, it sends XON, and the other end resumes transmission.
For example, imagine a
computer connected to a slow printer. The computer starts sending data to the printer. Since the computer is faster than the printer, the printer falls behind, and starts to be overwhelmed by the data. The printer thus sends XOFF to the computer. The software on the computer "sees" the XOFF, and temporarily stops sending data. Once the printer has "caught up", it sends XON to the computer. The computer sees XON, and starts sending data again.XOFF/XON can be employed in both directions -- for example, two
teleprinter s connected to each other.Comparison with hardware flow control
The principal advantage of software flow control is the reduction in the number of
electrical conductor s between sender and receiver. Given a common ground, only two signals are needed, one to send and the other to receive. Hardware flow control requires additional wires between the two devices. It also requires specific hardware implementation, which had more significant costs in earlier days of computing (i.e., 1960s and 70s).However, software flow control is not without its problems. Sending XOFF requires at least one character time to transmit, and may be queued behind already-transmitted data still in buffers. Hardware signals may be asserted almost instantaneously, and out-of-order.
As the name "software flow control" implies, flow control using this method is usually implemented in software (or at least a higher level of
firmware ), which can cause further delays in XOFF response. Hardware flow control is typically under the direct control of the transmitting UART, which is able to cease transmission immediately, without the intervention of higher levels.Finally, since the XOFF/XON codes are sent in-band, they cannot appear in the data being transmitted without being mistaken for flow control commands. Any data containing the XOFF/XON codes thus must be encoded in some manner for proper transmission, with corresponding overhead. This is frequently done with some kind of
escape sequence .Applications
Software flow control is used extensively by low-speed devices, especially older printers and
dumb terminal s, to indicate they are temporarily unable to accept more data. Typically, this is due to a combination of limitedoutput rate and anybuffer s being full. Some terminal control packages, such astermcap , employ "padding" to allow such equipment sufficient time to perform the requested actions without the need to assert XOFF.XOFF/XON are still sometimes used manually by computer operators, to pause and restart output which otherwise would scroll off the display too quickly.
Terminal emulator software generally implements XOFF/XON support as a basic function. This generally includes thesystem console on modernUnix andLinux machines, as well as GUI emulators such asxterm and theWin32 console .References
* [http://docs.hp.com/en/32022-90051/ch09s08.html How to control the flow of data: The XON/XOFF protocol] . In: Configuring Systems for Terminals, Printers, and Other Serial Devices: HP 3000 MPE/iX Computer Systems. Hewlett-Packard Company.
Wikimedia Foundation. 2010.