DCVG

DCVG

DCVG stands for Direct Current Voltage Gradient and is a survey technique used for assessing the effectiveness of corrosion protection on buried steel structures.[1] In particular, oil and natural gas pipelines are routinely monitored using this technique to help locate coating faults and highlight deficiencies in their cathodic protection (CP) strategies.

Contents

History

The DCVG method was invented by the late Australian John Mulvany, an ex telecomms engineer, in the early 1980s.[citation needed] He developed and refined the technique in conjunction with Dr John Leeds, a professional corrosion engineer from Kent, England.[citation needed] Today, the DCVG technique is universally accepted throughout the pipeline industry and has its own method formally defined by NACE International. Industry codes referring to pipe/pipeline inspection (such as API 571 and API RP 574, published by the American Petroleum Institute) reference it as a suitable method for determining coating breakdown in buried pipelines.

Background

Steel structures require protection if they are not to rapidly corrode, particularly if they are buried in moist soils or exposed to salt water. The primary form of corrosion protection is usually one or more protective coatings, such as paint, bitumen, resin etc. For buried pipelines (for example), this level of protection is insufficient in itself and is commonly supplemented by cathodic protection. As the pipeline ages and the coating(s) deteriorate, the cathodic protection becomes increasingly important in minimising corrosion damage. Assessing the condition of the pipeline coating(s) was previously only possible by excavating sections of the pipeline and the level of CP required was largely a matter of educated guesswork[citation needed]. The DCVG technique was developed to locate coating faults, quantify their severity and measure the effectiveness of the Cathodic protection used without having to disturb the pipeline.

Principles

Assuming that the buried pipeline is protected using Impressed Current Cathodic Protection (ICCP - as most are), then any defects in the coating will result in electrical current flowing from the surrounding soil and into the pipe. These currents cause voltage gradients to be set up in the soil, which can be measured using a voltmeter. By looking at the direction of these gradients, the location of coating faults may be identified. By plotting the direction of voltage gradients around a fault, the type and nature of faults may be deduced. By measuring the localised soil potentials with respect to remote earth, a measure of the effectiveness of the cathodic protection may be calculated.

Practical Methods

A Purpose-Built DCVG Meter

In theory, a standard analogue electronic multimeter could be used to perform a DCVG survey, but in practice it would be very difficult to take accurate readings and assess the direction of the voltage gradients correctly. A digital multimeter is completely unsuitable because of the difficulty in quickly assessing the direction of the voltage gradient. Specially designed DCVG meters are available, which have bespoke voltage ranges, specially designed transient response, rugged cases and (usually) a centre-zero meter movement for ease of use. The NACE method requires the measurements to be made using a pair of copper-copper(II) sulfate electrodes rather than simple metallic probes. In addition, the cathodic protection is switched on and off repeatedly using an electronic switch commonly referred to as an "interrupter". Thus, two voltage readings (the "on" and "off" potentials) are taken at each fault position. Counter-intuitively, it is actually the "off" potential (measured with respect to remote earth) which is regarded as more indicative of the effectiveness of the CP applied to the pipeline.

Pipelines which do not have any form of CP may be surveyed by using a temporary DC supply and anode bed. Long pipelines frequently have more than one DC supply for their CP, requiring a number of synchronised interrupters to perform a survey. DCVG surveys are often combined with other techniques, such as CIPS and soil resistivity as part of a comprehensive corrosion protection program.

Performing a DCVG survey is relatively simple - students or recent graduates are frequently employed to collect the data. Interpreting the results is a little more complicated and this task is usually performed by a specially trained corrosion engineer.

DCVG surveys may be performed by pipeline companies themselves or, more usually, by independent specialists.

References

  1. ^ Roberge, Pierre R. (2008). Corrosion engineering: principles and practice. McGraw-Hill. pp. 576. ISBN 9780071482431. 

Wikimedia Foundation. 2010.

Игры ⚽ Нужна курсовая?

Look at other dictionaries:

  • Gütesiegel FELIX — Der FELIX ist ein Gütesiegel des Deutschen Chorverbandes, mit dem Kindertagesstätten ausgezeichnet werden, die in besonderem Maße die musikalische Entwicklung der Drei bis Sechsjährigen fördern. Das Siegel wurde erstmals im Jahr 2000 vergeben.… …   Deutsch Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”