Peptide mass fingerprinting

Peptide mass fingerprinting

Citation maintenance. Please you see. Any concerns? Please . Peptide mass fingerprinting (PMF) (also known as protein fingerprinting) is an analytical technique for protein identification that was developed in 1993 by several groups independently.cite journal |author=Pappin DJ, Hojrup P, Bleasby AJ |title=Rapid identification of proteins by peptide-mass fingerprinting |journal=Curr. Biol. |volume=3 |issue=6 |pages=327–32 |year=1993 |pmid=15335725 |doi=10.1016/0960-9822(93)90195-T] cite journal |author=Henzel WJ, Billeci TM, Stults JT, Wong SC, Grimley C, Watanabe C |title=Identifying proteins from two-dimensional gels by molecular mass searching of peptide fragments in protein sequence databases |journal=Proc. Natl. Acad. Sci. U.S.A. |volume=90 |issue=11 |pages=5011–5 |year=1993 |pmid=8506346 |doi=10.1073/pnas.90.11.5011] cite journal |author=Mann M, Højrup P, Roepstorff P |title=Use of mass spectrometric molecular weight information to identify proteins in sequence databases |journal=Biol. Mass Spectrom. |volume=22 |issue=6 |pages=338–45 |year=1993 |pmid=8329463 |doi=10.1002/bms.1200220605] cite journal |author=James P, Quadroni M, Carafoli E, Gonnet G |title=Protein identification by mass profile fingerprinting |journal=Biochem. Biophys. Res. Commun. |volume=195 |issue=1 |pages=58–64 |year=1993 |pmid=8363627 |doi=10.1006/bbrc.1993.2009] cite journal |author=Yates JR, Speicher S, Griffin PR, Hunkapiller T |title=Peptide mass maps: a highly informative approach to protein identification |journal=Anal. Biochem. |volume=214 |issue=2 |pages=397–408 |year=1993 |pmid=8109726 |doi=10.1006/abio.1993.1514] In this method, the unknown protein of interest is first cleaved into smaller peptides, whose absolute masses can be accurately measured with a mass spectrometer such as MALDI-TOF or ESI-TOF.cite journal |author=Clauser KR, Baker P, Burlingame AL |title=Role of accurate mass measurement (+/- 10 ppm) in protein identification strategies employing MS or MS/MS and database searching |journal=Anal. Chem. |volume=71 |issue=14 |pages=2871–82 |year=1999 |pmid=10424174 |doi=10.1021/ac9810516] These masses are then "in silico" compared to either a database containing known protein sequences or even the genome. This is achieved by using computer programs that translate the known genome of the organism into proteins, then theoretically cut the proteins into peptides, and calculate the absolute masses of the peptides from each protein. They then compare the masses of the peptides of the unknown protein to the theoretical peptide masses of each protein encoded in the genome. The results are statistically analyzed to find the best match.
The advantage of this method is that only the masses of the peptides have to be known and as such, "de novo" peptide sequencing is not necessary which can be time consuming. A disadvantage is that the protein sequence has to be present in the database of interest. Additionally most PMF algorithms assume that the peptides come from a single protein.cite journal |author=Shevchenko A, Jensen ON, Podtelejnikov AV, Sagliocco F, Wilm M, Vorm O, Mortensen P, Shevchenko A, Boucherie H, Mann M |title=Linking genome and proteome by mass spectrometry: large-scale identification of yeast proteins from two dimensional gels |journal=Proc. Natl. Acad. Sci. U.S.A. |volume=93 |issue=25 |pages=14440–5 |year=1996 |pmid=8962070 |doi=10.1073/pnas.93.25.14440] The presence of a mixture can significantly complicate the analysis and potentially compromise the results.Typical for the PMF based protein identification is the requirement for an isolated protein. Mixtures exceeding a number of 2-3 proteins typically require the additional use of MS/MS based protein identification to achieve sufficient specificity of identification (6). Therefore, the typical PMF samples are isolated proteins from Two-dimensional gel electrophoresis (2D gels) or isolated SDS-PAGE bands. Additional analyses by MS/MS can either be direct, e.g., MALDI-TOF/TOF analysis or downstream nanoLC-ESI-MS/MS analysis of gel spot eluates. ] cite journal |author=Wang W, Sun J, Nimtz M, Deckwer WD, Zeng AP |title=Protein identification from two-dimensional gel electrophoresis analysis of Klebsiella pneumoniae by combined use of mass spectrometry data and raw genome sequences |journal= Proteome Science|volume=1 |issue=1 |pages=6 |year=2003 |pmid=14653859 |doi=10.1186/1477-5956-1-6] cite journal |author=Hufnagel P, Rabus R |title=Mass spectrometric identification of proteins in complex post-genomic projects. Soluble proteins of the metabolically versatile, denitrifying 'Aromatoleum' sp. strain EbN1 |journal=J. Mol. Microbiol. Biotechnol. |volume=11 |issue=1-2 |pages=53–81 |year=2006 |pmid=16825790 |doi=10.1159/000092819]

ample preparation

Protein samples can be derived from SDS-PAGE ] and are then subject to some chemical modifications. Disulfide bridges in proteins are reduced and cysteine amino acids are carboxymethylated chemically or acrylamidated during the gel electrophoresis.

Then the proteins are cut into several fragments using proteolytic enzymes such as trypsin, chymotrypsin or Glu-C. A typical sample:protease ratio is 50:1. The proteolysis is typically carried out overnight and the resulting peptides are extracted with acetonitrile and dried under vacuum. The peptides are then dissolved in a small amount of distilled water and are ready for mass spectrometric analysis.

Mass spectrometric analysis

The digested protein can be analyzed with different types of mass spectrometers such as ESI-TOF or MALDI-TOF. MALDI-TOF is often the preferred instrument because it allows a high sample throughput and several proteins can be analyzed in a single experiment - if complemented by MS/MS analysis.

A small fraction of the peptide (usually 1 microliter or less) is pipetted onto a MALDI target and a chemical called a matrix is added to the peptide mix. The matrix molecules are required for the desorption of the peptide molecules. Matrix and peptide molecules co-crystallize on the MALDI target and are ready to be analyzed.

The target is inserted into the vacuum chamber of the mass spectrometer and the analysis of peptide masses is initiated by a pulsed laser beam which transfers high amounts of energy into the matrix molecules. The energy transfer is sufficient to promote the transition of matrix molecules and peptides from the solid state into the gas state. Then the molecules become accelerated in the electric field of the mass spectrometer and fly towards an ion detector where their arrival is detected as an electric signal. Their mass is proportional to their time of flight (TOF) in the drift tube and can be calculated accordingly.

Computational analysis

The mass spectrometrical analysis produces a list of molecular weights which is often called peak list. The peptide masses are now compared to huge databases such as Swissprot, Genbank which contain protein sequence information. Software programs (see web resources and references in Hufnagel, 2006 ] ) cut all these proteins into peptides with the same enzyme used in the chemical cleavage (for example trypsin). The absolute mass of all these peptides is then theoretically calculated. A comparison is made between the peak list of measured peptide masses and all the masses from the calculated peptides. The results are statistically analyzed and possible matches are returned in a results table.

ee also

*Protein mass spectrometry
* Shotgun proteomics
* Top-down proteomics
* Bottom-up proteomics

References

External links

* [http://www.aber.ac.uk/parasitology/Proteome/MS_Tut.html PMF Tutorial]


Wikimedia Foundation. 2010.

Игры ⚽ Нужна курсовая?

Look at other dictionaries:

  • Mass spectrometry — (MS) is an analytical technique that measures the mass to charge ratio of charged particles.[1] It is used for determining masses of particles, for determining the elemental composition of a sample or molecule, and for elucidating the chemical… …   Wikipedia

  • Peptide — Peptides redirects here. For the journal, see Peptides (journal). A tetrapeptide (example Val Gly Ser Ala) with green marked amino end (L Valine) and …   Wikipedia

  • Protein mass spectrometry — A mass spectrometer used for high throughput protein analysis. Protein mass spectrometry refers to the application of mass spectrometry to the study of proteins. Mass spectrometry is an important emerging method for the characterization of… …   Wikipedia

  • Liquid chromatography-mass spectrometry — Infobox chemical analysis name = Liquid chromatography mass spectrometry caption =Ion trap LCMS system acronym = LCMS classification =Chromatography Mass spectrometry analytes = organic molecules biomolecules manufacturers = Agilent Bruker MDS… …   Wikipedia

  • Protein fingerprinting — can refer to any of the several methods for identifying or differentiating proteins: *Peptide mass fingerprinting, a method developed in 1993 that uses protein mass spectrometry following SDS PAGE *Older techniques using two dimensional… …   Wikipedia

  • Sample preparation (mass spectrometry) — The sample preparation for mass spectrometry is used for the optimisation of a sample for the analysis in a mass spectrometer (MS).These have depending on their ion source different requirements for volume, concentration, and composition of the… …   Wikipedia

  • Inductively coupled plasma mass spectrometry — ICP MS Instrument Acronym ICP MS Classification Mass spectrometry Analytes atomic and polyatomic species in plasma, with exceptions; usually inte …   Wikipedia

  • Huella peptídica — Secuenciación de una proteína mediante huella peptídica. La huella peptídica o PMF (del inglés Peptide mass fingerprinting), es una técnica analítica de identificación de proteínas desarrollada en 1993 por varios grupos de forma independiente …   Wikipedia Español

  • Matrix-assisted laser desorption/ionization — MALDI TOF mass spectrometer Matrix assisted laser desorption/ionization (MALDI) is a soft ionization technique used in mass spectrometry, allowing the analysis of biomolecules (biopolymers such as DNA, proteins, peptides and sugars) and large… …   Wikipedia

  • Gel electrophoresis — apparatus – An agarose gel is placed in this buffer filled box and electrical field is applied via the power supply to the rear. The negative terminal is at the far end (black wire), so DNA migrates toward the camera. Classification… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”