Liquid chromatography-mass spectrometry

Liquid chromatography-mass spectrometry

Infobox chemical analysis
name = Liquid chromatography-mass spectrometry



caption =Ion trap LCMS system
acronym = LCMS
classification =Chromatography
Mass spectrometry
analytes = organic molecules
biomolecules
manufacturers = Agilent
Bruker
MDS
Shimadzu Scientific
Thermo Fisher Scientific
Varian, Inc.
Waters Corporation
related = Gas chromatography-mass spectrometry
hyphenated =

Liquid chromatography-mass spectrometry (LC-MS) is an analytical chemistry technique that combines the physical separation capabilities of liquid chromatography (or HPLC) with the mass analysis capabilities of mass spectrometry. LC-MS is a powerful technique used for many applications which has very high sensitivity and specificity. Generally its application is oriented towards the specific detection and potential identification of chemicals in the presence of other chemicals (in a complex mixture).

Liquid chromatography

cale

A major difference between traditional HPLC and the chromatography used in LC-MS is that in the latter case the scale is usually much smaller, both with respect to the internal diameter of the column and even more so with respect to flow rate since it scales as the square of the diameter. For a long time, 1 mm columns were typical for LC-MS work (as opposed to 4.6 mm for HPLC). More recently 300mum and even 75mum capillary columns have become more prevalent. At the low end of these column diameters the flow rates approach 100nL/min and are generally used with nanospray sources. [ [http://dx.doi.org/10.1002/mas.1280130504 Capillary liquid chromatography/mass spectrometry, Kenneth B. Tomer, M. Arthur Moseley, Leesa J. Deterding, Carol E. Parker, Mass Spectrometry Reviews, Vol 13, 1994, pp 431-457] ]

Flow splitting

When standard bore (4.6 mm) columns are used the flow is often split ~10:1. This can be beneficial by allowing the use of other techniques in tandem such as MS and UV. However splitting the flow to UV will decrease the sensitivity of spectrophotometric detectors. The Mass Spec on the other hand will give improved sensitivity at flow rates of 200 μL/min or less. This is because the analyte ions have to be vaporised (nebulized) in order to become charged.

Mass spectrometry

Mass analyzer

There are a lot of mass analyzers that can be used in LC/MS. Single Quadrupole, Triple Quadrupole, Ion Trap, TOF (time of Flight) and Quadrupole-time of flight (Q-TOF).

Interface

Understandably the interface between a liquid phase technique which continuously flows liquid, and a gas phase technique carried out in a vacuum was difficult for a long time. The advent of electrospray ionization changed this. The interface is most often an electrospray ion source or variant such as a nanospray source; however fast atom bombardment, thermospray and atmospheric pressure chemical ionization interfaces are also used. [ [http://dx.doi.org/10.1002/mas.1280110103 Combined liquid chromatography mass spectrometry. Part III. Applications of thermospray, Patrick Arpino, Mass Spectrometry Reviews, Vol 11, 1992 pp 3-40] ] Various deposition and drying techniques have also been used such as using moving belts; however the most common of these is off-line MALDI deposition. [Combined liquid chromatography mass spectrometry. Part I. Coupling by means of a moving belt interface, Patrick Arpino, Mass Spectrometry Reviews, Vol 8, 1989 pp 35-55] [ [http://www3.interscience.wiley.com/cgi-bin/abstract/10009479/ABSTRACT Coupling matrix-assisted laser desorption/ionization to liquid separations, Kermit K. Murray, Mass Spectrometry Reviews, Vol 16, pp 283-299] ]

Applications

Pharmacokinetics

LC-MS is very commonly used in pharmacokinetic studies of pharmaceuticals. These studies tell us how quickly a drug will be cleared from the hepatic blood flow, and organs of the body. MS is used for this due to high sensitivity and exceptional specificity compared to UV (as long as the analyte can be suitably ionised), and short analysis time.

The major advantage MS has is the use of tandem MS-MS. You can program the detector to select certain ions to fragment. The process is essentially a selection technique, but is in fact more complex. The measured quantity is the sum of molecule fragments chosen by the operator. As long as there are no interferences or ion suppression, the LC separation can be quite quick. It is common now to have analysis times of 1 minute or less by MS-MS detection, compared to over 10 mins with UV detection. [Increasing Speed and Throughput When Using HPLC-MS/MS Systems for Drug Metabolism and Pharmacokinetic Screening, Y. Hsieh and W.A. Korfmacher, Current Drug Metabolism Volume 7, Number 5, 2006, Pp. 479-489] [Covey TR, Lee ED, Henion JD. 1986. High-speed liquid chromatography/tandem mass spectrometry for the determination of drugs in biological samples. Anal Chem 58:2453-2460.] [Thermospray liquid chromatography/mass spectrometry determination of drugs and their metabolites in biological fluids. Covey TR et al. Anal Chem. 1985 Feb;57(2):474-81]

Proteomics

LC-MS is also used in the study of proteomics where again components of a complex mixture must be detected and identified in some manner. The bottom-up proteomics LC-MS approach to proteomics generally involves protease digestion (usually Trypsin) followed by LC-MS with peptide mass fingerprinting or LC-MS/MS (tandem MS) to derive sequence of individual peptides.

Drug development

LC-MS is frequently used in drug development at many different stages including Peptide Mapping, Glycoprotein Mapping, Natural Products Dereplication, Bioaffinity Screening, In Vivo Drug Screening, Metabolic Stability Screening, Metabolite Identification, Impurity Identification, Degradant Identification, Quantitative Bioanalysis, and Quality Control. [ [http://www3.interscience.wiley.com/cgi-bin/abstract/66004558/ABSTRACT LC/MS applications in drug development, Mass Spectrometry Reviews, Mike S. Lee, Edward H. Kerns, Vol 18, 1999, pp 187-279] ]

ee also

* Gas chromatography-mass spectrometry
* Ion mobility spectrometry-mass spectrometry

References

Bibliography

*cite book |author=Thurman, E. M.; Ferrer, Imma |title=Liquid chromatography/mass spectrometry, MS/MS and time of flight MS: analysis of emerging contaminants |publisher=American Chemical Society |location=Columbus, OH |year=2003 |pages= |isbn=0-8412-3825-1 |oclc= |doi=
*cite book |author=Ardrey, R. E.; Ardrey, Robert |title=Liquid chromatography-mass spectrometry: an introduction |publisher=J. Wiley |location=London |year=2003 |pages= |isbn=0-471-49801-7 |oclc= |doi=
*cite book |author=McMaster, Marvin C. |title=LC/MS: a practical user's guide |publisher=John Wiley |location=New York |year=2005 |pages= |isbn=0-471-65531-7 |oclc= |doi=
*cite book |author=Wilfried M.A. Niessen, Wilfried M. Niessen |title=Liquid Chromatography-Mass Spectrometry, Third Edition (Chromatographic Science) |publisher=CRC |location=Boca Raton |year= 2006 |pages= |isbn=0-8247-4082-3 |oclc= |doi=
*cite book |author=Yergey, Alfred L. |title=Liquid chromatography/mass spectrometry: techniques and applications |publisher=Plenum Press |location=New York |year=1990 |pages= |isbn=0-306-43186-6 |oclc= |doi=


Wikimedia Foundation. 2010.

Игры ⚽ Нужна курсовая?

Look at other dictionaries:

  • Gas chromatography-mass spectrometry — (GC MS) is a method that combines the features of gas liquid chromatography and mass spectrometry to identify different substances within a test sample. Applications of GC MS include drug detection, fire investigation, environmental analysis,… …   Wikipedia

  • Mass spectrometry — (MS) is an analytical technique that measures the mass to charge ratio of charged particles.[1] It is used for determining masses of particles, for determining the elemental composition of a sample or molecule, and for elucidating the chemical… …   Wikipedia

  • Mass spectrometry software — is software used for data acquisition, analysis, or representation in mass spectrometry. Contents 1 MS/MS peptide identification 1.1 Database search algorithms 1.1.1 SEQUEST 1.1.2 …   Wikipedia

  • Membrane-introduction mass spectrometry — (MIMS) is a method of introducing analytes into the mass spectrometer s vacuum chamber via a semipermeable membrane.[1][2] Usually a thin, gas permeable, hydrophobic membrane is used, for example polydimethylsiloxane. Samples can be almost any… …   Wikipedia

  • Membrane introduction mass spectrometry — (MIMS) is a method of introducing analytes into the mass spectrometer s vacuum chamber via a semipermeable membrane.cite journal |author=Johnson RC, Cooks RG, Allen TM, Cisper ME, Hemberger PH |title=Membrane introduction mass spectrometry:… …   Wikipedia

  • mass spectrometry — or mass spectroscopy Analytic technique by which chemical substances are identified by sorting gaseous ions by mass using electric and magnetic fields. A mass spectrometer uses electrical means to detect the sorted ions, while a mass spectrograph …   Universalium

  • High-performance liquid chromatography — An HPLC. From left to right: A pumping device generating a gradient of two different solvents, a steel enforced column and an apparatus for measuring the absorbance. Acronym HPLC Classification Chromatography …   Wikipedia

  • High performance liquid chromatography — Infobox chemical analysis name = High performance liquid chromatography caption =A HPLC. From left to right: A pumping device generating a gradient of two different solvents, a steel enforced column and an apparatus for measuring the absorbance.… …   Wikipedia

  • Mass spectrometry data format — Mass spectrometry is a scientific technique for measuring the mass of ions. It is often coupled to chromatographic techniques such as gas or liquid chromatography and has found widespread adoption in the fields of analytical chemistry and… …   Wikipedia

  • Ion mobility spectrometry-mass spectrometry — (IMS MS) is a method that combines the features of ion mobility spectrometry and mass spectrometry to identify different substances within a test sample.HistoryOn the one hand, ion mobility spectrometry was developed in the 70s and typically… …   Wikipedia