Wet scrubber

Wet scrubber

Wet scrubber is a form of pollution control technology. The term describes a variety of devices that use pollutants from a furnace flue gas or from other gas streams. In a wet scrubber, the polluted gas stream is brought into contact with the scrubbing liquid, by spraying it with the liquid, by forcing it through a pool of liquid, or by some other contact method, so as to remove the pollutants.

The design of wet scrubbers or any air pollution control device depends on the industrial process conditions and the nature of the air pollutants involved.

Inlet gas characteristics and dust properties (if particles are present) are of primary importance. Scrubbers can be designed to collect particulate matter and/or gaseous pollutants. Wet scrubbers remove dust particles by "capturing" them in liquid droplets. Wet scrubbers remove pollutant gases by "dissolving" or "absorbing" them into the liquid.

Any droplets that are in the scrubber inlet gas must be separated from the outlet gas stream by means of another device referred to as a mist eliminator or entrainment separator (these terms are interchangeable). Also, the resultant scrubbing liquid must be treated prior to any ultimate discharge or being reused in the plant.

There are numerous configurations of scrubbers and scrubbing systems, all designed to provide good contact between the liquid and polluted gas stream.

Figures 1 and 2 show two examples of wet scrubber designs, including their mist eliminators. Figure 1 is a venturi scrubber design. The mist eliminator for a venturi scrubber is often a separate device called a cyclonic separator. Figure 2 has a tower design where the mist eliminator is built into the top of the structure. Various tower designs exist.

A wet scrubber's ability to collect small particles is often directly proportional to the power input into the scrubber. Low energy devices such as spray towers are used to collect particles larger than 5 micrometers. To obtain high efficiency removal of 1 micrometer (or less) particles generally requires high energy devices such as venturi scrubbers or augmented devices such as condensation scrubbers. Additionally, a properly designed and operated entrainment separator or mist eliminator is important to achieve high removal efficiencies. The greater the number of liquid droplets that are not captured by the mist eliminator the higher the potential emission levels.

Wet scrubbers that remove gaseous pollutants are referred to as "absorbers". Good gas-to-liquid contact is essential to obtain high removal efficiencies in absorbers. A number of wet scrubber designs are used to remove gaseous pollutants, with the packed tower and the plate tower being the most common.

If the gas stream contains both particle matter and gases, wet scrubbers are generally the only single air pollution control device that can remove both pollutants. Wet scrubbers can achieve high removal efficiencies for either particles or gases and, in some instances, can achieve a high removal efficiency for both pollutants in the same system. However, in many cases, the best operating conditions for particles collection are the poorest for gas removal.

In general, obtaining high simultaneous gas and particulate removal efficiencies requires that one of them be easily collected (i.e., that the gases are very soluble in the liquid or that the particles are large and readily captured) or by the use of a scrubbing reagent such as lime or sodium hydroxide.

Advantages and disadvantages

For particulate control, wet scrubbers (also referred to as wet collectors) are evaluated against fabric filters and electrostatic precipitators (ESPs). Some "advantages" of wet scrubbers over these devices are as follows:

*Wet scrubbers have the ability to handle high temperatures and moisture.
*In wet scrubbers, the inlet gases are cooled, resulting in smaller overall size of equipment.
*Wet scrubbers can remove both gases and particulate matter.
*Wet scrubbers can neutralize corrosive gases.

Some "disadvantages" of wet scrubbers include corrosion, the need for entrainment separation or mist removal to obtain high efficiencies and the need for treatment or reuse of spent liquid.

Table 1 summarizes these advantages and disadvantages. Wet scrubbers have been used in a variety of industries such as acid plants, fertilizer plants, steel mills, asphalt plants, and large power plants.



Wet scrubber systems

Wet scrubber systems generally consist of the following components:

* Ductwork and fan system
* A saturation chamber (optional)
* Scrubbing vessel
* Entrainment separator or mist eliminator
* Pumping (and possible recycle system)
* Spent scrubbing liquid treatment and/or reuse system
* An exhaust stack

A typical wet scrubbing process can be described as follows:

* Hot flue gas from a furnace enters a saturator (if present) where gases are cooled and humidified prior to entering the scrubbing area. The saturator removes a small percentage of the particulate matter present in the flue gas.
* Next, the gas enters a venturi scrubber where approximately half of the gases are removed. Venturi scrubbers have a minimum particle removal efficiency of 95%.
* The gas flows through a second scrubber, a packed bed absorber, where the rest of the gases (and particulate matter) are collected.
* A entrainment separator or mist eliminator removes any liquid droplets that may have become entrained in the flue gas.
* A recirculation pump moves some of the spent scrubbing liquid back to the venturi scrubber where it is recycled and the remainder is sent to a treatment system.
* Treated scrubbing liquid is recycled back to the saturator and the packed bed absorber.
* Fans and ductwork move the flue gas stream through the system and eventually out the stack.

Categorization of wet scrubbers

Since wet scrubbers vary greatly in complexity and method of operation, devising categories into which all of them neatly fit is extremely difficult. Scrubbers for particle collection are usually categorized by the gas-side pressure drop of the system. Gas-side pressure drop refers to the pressure difference, or pressure drop, that occurs as the exhaust gas is pushed or pulled through the scrubber, disregarding the pressure that would be used for pumping or spraying the liquid into the scrubber.

Scrubbers may be classified "by pressure drop" as follows:

*Low-energy scrubbers have pressure drops of less than 12.7 cm (5 in) of water.
*Medium-energy scrubbers have pressure drops between 12.7 and 38.1 cm (5 and 15 in) of water.
*High-energy scrubbers have pressure drops greater than 38.1 cm (15 in) of water.

However, most scrubbers operate over a wide range of pressure drops, depending on their specific application, thereby making this type of categorization difficult.

Another way to classify wet scrubbers is by their "use" - to primarily collect either particulates or gaseous pollutants. Again, this distinction is not always clear since scrubbers can often be used to remove both types of pollutants.

Wet scrubbers can also be categorized by the manner in which the gas and liquid phases are brought into contact. Scrubbers are designed to use power, or energy, from the gas stream or the liquid stream, or some other method to bring the pollutant gas stream into contact with the liquid. These categories are given in Table 2. [ [http://www.epa.gov/apti/ US EPA Air Pollution Training Institute] developed in collaboration with North Carolina State University, College of Engineering (NCSU)]



Bibliography

*Bethea, R. M. 1978. Air Pollution Control Technology. New York: Van Nostrand Reinhold.
*Perry, J. H. (Ed.). 1973. Chemical Engineers’ Handbook. 5th ed. New York: McGraw-Hill.
*Richards, J. R. 1995. Control of Particulate Emissions (APTI Course 413). U.S. Environmental Protection Agency.
*Richards, J. R. 1995. Control of Gaseous Emissions. (APTI Course 415). U.S. Environmental Protection Agency.
*Semrau, K. T. 1977. Practical process design of particulate scrubbers. Chemical Engineering. 84:87-91.

References

* [http://www.mon-env.com/air-scrubbers.htm Monroe Environmental Wet Air Scrubbers] Manufacturer, drawings, photographs, diagrams and descriptions.


Wikimedia Foundation. 2010.

Игры ⚽ Поможем написать реферат

Look at other dictionaries:

  • Scrubber — This article is about the pollution control device, for other uses, see scrubber (disambiguation).Scrubber systems are a diverse group of air pollution control devices that can be used to remove some particulates and/or gases from industrial… …   Wikipedia

  • Particle collection in wet scrubbers — Wet scrubbers capture relatively small dust s with large liquid droplets. In most wet scrubbing systems, droplets produced are generally larger than 50 micrometres (in the 150 to 500 micrometres range). As a point of reference, human hair ranges… …   Wikipedia

  • Mechanically aided scrubber — Figure 1 Centrifugal fan scrubber Mechanically aided scrubbers are a form of pollution control technology. This type of technology is a part of the group of air pollution controls collectively referred to as wet scrubbers. In addition to using… …   Wikipedia

  • Venturi scrubber — A venturi scrubber is designed to effectively use the energy from the inlet gas stream to atomize the liquid being used to scrub the gas stream. This type of technology is a part of the group of air pollution controls collectively referred to as… …   Wikipedia

  • Cyclonic spray scrubber — Figure 1 Irrigated cyclone scrubber Cyclonic spray scrubbers are an air pollution control technology. They use the features of both the dry cyclone and the spray chamber to remove pollutants from gas streams. Generally, the inlet gas enters the… …   Wikipedia

  • Ejector venturi scrubber — This type of technology is a part of the group of air pollution controls collectively referred to as wet scrubbers.An ejector or venturi scrubber is an industrial pollution control device, usually installed on the exhaust flue gas stacks of large …   Wikipedia

  • Baffle spray scrubber — Baffle spray scrubbers are a technology for air pollution control. They are very similar to spray towers in design and operation. However, in addition to using the energy provided by the spray nozzles, baffles are added to allow the gas stream to …   Wikipedia

  • Dust collector — Two rooftop dust collectors in Pristina, Kosovo A dust collector is a system used to enhance the quality of air released from industrial and commercial processes by collecting dust and other impurities from air or gas. Designed to handle heavy… …   Wikipedia

  • Flue gas desulfurization — (FGD) is the technology used for removing sulfur dioxide (SO2) from the exhaust flue gases in power plants that burn coal or oil to produce steam for the steam turbines that drive their electricity generators. Sulfur dioxide is responsible for… …   Wikipedia

  • Rebreather — A fully closed circuit electronic rebreather (Ambient Pressure Diving Inspiration) Acronym CCUBA (Closed Circuit Underwater Breathing Apparatus); CCR (Closed circuit rebreather), SCR (Semi closed rebreather) Uses Breathing set …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”