- Earthquake engineering
Earthquake engineering is the study of the behavior of buildings and structures subject to
seismic loading . It is a subset of both structural andcivil engineering .The main objectives of earthquake engineering are:
* Understand the interaction between buildings or civilinfrastructure and the ground.
* Foresee the potential consequences of earthquakes.
* Design, construct and maintain structures to perform at earthquake exposure up to the expectations and in compliance withbuilding code s.A properly engineered structure does not necessarily have to be extremely strong or expensive.
The most powerful and budgetary tools of
earthquake engineering arevibration control technologies and, in particular,base isolation .eismic loading
Seismic loading means application of an earthquake-generated agitation to a structure. It happens at contact surfaces of a structure either with the ground [http://earthquake.geoengineer.org/] , or with adjacent structures [http://www.civenv.unimelb.edu.au/ejse/Archives/Fulltext/2006/200608.pdf] , or with
gravitational wave s fromtsunami . Seismic loading depends, primarily, on:* Anticipated earthquake's parameters at the site
*Geotechnical parameters of the site
*Structure 's parameters
* Characteristics of the anticipated gravitational waves from tsunami (if applicable).Sometimes, seismic load exceeds ability of a structure to resist it without being broken, partially or completely. Due to their mutual interaction, seismic loading and
seismic performance of a structure are intimately related.eismic performance
Earthquake or seismic performance is an execution of a building's or structure's ability to sustain their due functions, such as its
safety andserviceability , "at" and "after" a particular earthquake exposure. A structure is, normally, considered "safe" if it does not endanger the lives and wellbeing of those in or around it by partially or completely collapsing. A structure may be considered "serviceable" if it is able to fulfill its operational functions for which it was designed.Basic concepts of the earthquake engineering, implemented in the major building codes, assume that a building should survive The Big One (the most powerful anticipated earthquake) though with partial destruction. Drawing an analogy with a human body, it will have dislocated joints, fractured ribs, traumatized spine and knocked out teeth but be alive and, therefore, acceptable according to the prescriptivebuilding code s [http://www.seaint.org/seaocconvention/convention1999/Proceedings/A_NEW_CONCEPT.pdf] . This situation is a major barrier to implementation of any structural innovations in the earthquake engineering technologies employing vibration control and, particularly, the most effective brands of base isolation.However, alternative earthquake performance-based design approaches already exist. Some of them, for assessment or comparison of the anticipated earthquake performance, use the "Story Performance Rating" R as a major criterion [http://www.ecs.csun.edu/~shustov/Topic7.htm] while the "Seismic Performance Ratio" (SPR) is used for a rather accurate prediction of earthquake performance of a building up to the point of its state of "severe damage" [https://central.nees.org/data/get/NEES-2006-0283/Public/REPORT.pdf] .
eismic performance evaluation
Performance evaluation of building structures at their earthquake exposure is one of the hottest topics of earthquake engineering [http://www.ecs.csun.edu/~shustov/Hot_Topics.htm] . Engineers need to know the quantified level of an actual or anticipated seismic performance associated with the direct damage to an individual building subject to a specified ground shaking.
The best way to do it is to put the structure on a shake-table that simulates the earth shaking and watch what may happen next (if you have no time to stand out in the field and wait for a real earthquake to strike, of course). [https://central.nees.org/data/get/NEES-2006-0283/Public/REPORT.pdf] .
On demand, all virtual EPET experiments on two identical building models can be animated [https://central.nees.org/data/get/NEES-2006-0283/Public/EPET_release.pdf] . Any building or its model is treated here as an essentially
nonlinear system . Major building* "Ground Acceleration Mitigation Factor", when only some maximum accelerations on a structure are available [http://www.ecs.csun.edu/~shustov/Topic2.htm] , and
* "Story Performance Rating", when the story drifts are also known [http://www.ecs.csun.edu/~shustov/Topic7.htm] .The parameter called "Seismic Performance Ratio" may be chosen as the primary parameter which would control anticipated losses due to a particular seismic exposure of the building.
NEEScentral portal hosts valuable data on experimental validation of EPET, including some movie clips on the comparative shake-table testing of 6- and 12-story building models [https://central.nees.org/data/get/NEES-2006-0283/Public/5th%20NEES%20Meeting%20Presentation.ppt] . EPET can use either real time-histories or
earthquake simulation s and predictseismic performance of a building up to the point of its virtual state of "severe damage" [http://www.epet.space3d.biz/] .eismic performance analysis
Seismic performance analysis or, simply,
seismic analysis is a major intellectual tool of earthquake engineering which breaks the complex topic into smaller parts to gain a better understanding ofseismic performance of building andnon-building structure s. The technique as a formal concept is a relatively recent development. method which, also, contributed to the proposed building code's concept of today [http://www.ecs.csun.edu/~shustov/Topic7.htm] .However, those spectra are good, mostly, for single-degree-of-freedom systems. Numerical "step-by-step integration"cite book|title= Dynamics of Structures|author=Clough, Ray W.; Penzien, Joseph|date=1993|publisher=McGraw-Hill|isbn=0070113947] , applied with the "charts of seismic performance" [http://www.ecs.csun.edu/~shustov/Topic6.htm] , proved to be a more effective method of analysis for multi-degree-of-freedom
structural system s with severenon-linearity under a substantiallytransient process of kinematicexcitation .Research for earthquake engineering
Research for earthquake engineering incorporates both field and analyticalinvestigation orexperimentation aimed atdiscovery andinterpretation of earthquake engineering related facts,revision of accepted theories in the light of new facts, or "practical application" of such new or revised theories.The
National Science Foundation (NSF) is the main United States government agency that supports fundamental research and education in all fields of earthquake engineering. In particular, it focuses on experimental, analytical, and computational research on design and performance enhancement of structural systems.Research programs
The NSF programs support research on new technologies for improving the behavior and response of structural systems subject to earthquake hazards; fundamental research on safety and reliability of constructed systems; innovative developments in analysis and model based simulation of structural behavior and response including soil-structure interaction; design concepts that improve structure performance and flexibility; and application of new control techniques for structural systems [http://www.nsf.gov/funding/pgm_summ.jsp?pims_id=13358&org=CMMI] . NSF also supports George E. Brown, Jr. Network for Earthquake Engineering Simulation (NEES) [http://www.nees.org/] that advances knowledge discovery and innovation for earthquake and tsunami loss reduction of the nation's civil infrastructure, and new experimental simulation techniques and instrumentation.
s, geotechnical centrifuges, a tsunami wave basin, unique large-scale testing laboratory facilities, and mobile and permanently installed field equipment [http://www.nees.org/5am/sessions.php] .
NEES Cyberinfrastructure Center (NEESit) connects, via Internet2, the equipment sites as well as providestelepresence , a curated centraldata repository , simulation tools, and collaborative tools for facilitating on-line planning, execution, andpost-processing of experiments.Earthquake simulation
The very first earthquake simulations were performed by statically applying some "horizontal inertia forces" based on
scale dpeak ground acceleration s to a mathematical model of a building cite book|title= Seismic Design of Building Structures|author=Lindeburg, Michael R.; Baradar, Majid|date=2001|publisher=Professional Publications|isbn=1888577525] . With the further development of computational technologies,static approaches began to give way todynamic ones.Dynamic experiments on building andnon-building structure s may be physical, like shake-table testing, or virtual ones. In both cases, to verify a structure's expectedseismic performance , some researchers prefer to deal with so called "real time-histories" though the last cannot be "real" for a hypothetical earthquake specified by either a building code or by some particular research requirements. Therefore, there is a strong incentive to engage an earthquake simulation which is the seismic input that possesses only essential features of a real event, like, e.g., the earthquake simulating displacement time-history "Cone" [https://central.nees.org/data/get/NEES-2006-0283/Public/REPORT.pdf] presented above.Earthquake simulations have been widely used in the research of
Earthquake Protector and development of the EPET which was supported by The George E. Brown Network for Earthquake Engineering Simulation (NEES) [http://www.nsf.gov/news/special_reports/nees/about.jsp] .Sometimes, earthquake simulation is understood as a re-creation of local effects of a strong earth shaking [http://tw.youtube.com/watch?v=UcgRtZKRip0] .
tructure simulation
Theoretical or experimental evaluation of anticipated
seismic performance mostly requires a structure simulation which is based on the concept of structural likeness or similarity.Similarity is some degree ofanalogy orresemblance between two or more objects. The notion of similarity rests either on exact or approximate repetitions ofpatterns in the compared items.if the two share geometric similarity, kinematic similarity and dynamic similarity. The most vivid and effective type of similarity is the kinematic one. Kinematic similarity is the similarity of time as well as geometry. It exists between a model and prototype when:
* the paths of moving particles are geometrically similar;
* the ratios of the velocities of particles are similar.The ultimate level of kinematic similarity is kinematic equivalence when, in the case of earthquake engineering, time-histories of each story lateral displacements of the model and its prototype would be the same [https://central.nees.org/data/get/NEES-2006-0283/Public/REPORT.pdf] .
eismic vibration control
Seismic vibration control is a set of technical means aimed to mitigate seismic impacts in building and
non-building structures [http://www.ecs.csun.edu/~shustov/Seismic_Control_Directory.html] . All seismic vibration control devices may be classified as "passive", "active" or "hybrid" [http://physics-animations.com/Physics/English/spri_txt.htm] where:* "passive control devices" have no
feedback capability between them, structural elements and the ground;
* "active control devices" are force delivery devices integrated with real-time processing sensors and evaluators/controllers within the structure and on the ground;
* "hybrid control devices" have combined features of active and passive control systems.cite book|title= Active, Hybrid and Semi-Active Structural Control|author=Chu, S.Y.; Soong, T.T.; Reinhorn, A.M.|date=2005|publisher= John Wiley & Sons |isbn=0470013524]When ground
seismic waves reach up and start to penetrate a base of a building, their energy flow density, due to reflections, reduces dramatically: usually, up to 90%. However, the remaining portions of the incident waves during a major earthquake still bear a huge devastating potential.After the seismic waves enter a
superstructure , there is a number of ways to control them in order to sooth their damaging effect and improve the building'sseismic performance , for instance:* to dissipate the wave energy inside a
superstructure with properly engineereddamper s;* to
disperse the wave energy between a wider range of frequencies by adequately "configuring a building elevation" [http://www.ecs.csun.edu/~shustov/Topic5.htm] ;* to
reflect ,diffract , and dissipate seismic waves in a process of their vertical propagation with the help of "elevated building foundation" (EBF) [https://central.nees.org/data/get/NEES-2006-0283/Public/EBF%20and%20EP.pdf] ;* to
absorb theresonant portions of the whole wave frequencies band with the help of so called "mass damper s" [http://ffden-2.phys.uaf.edu/211_fall2002.web.dir/Eva_Burk/Eva's%201st%20page.htm] .Devices of the last kind, abbreviated correspondingly as TMD for the tuned ("passive"), as AMD for the "active", and as HMD for the "hybrid mass dampers", have been studied and installed in
high-rise building s, predominantly in Japan, for a quarter of a century [http://www.takenaka.co.jp/takenaka_e/quake_e/seishin/seishin.htm] .To increase the shielded range of forcing frequencies, the concept of "Multi-Frequency Quieting Building System" (MFQBS) was developed in U.S. [http://www.ecs.csun.edu/~shustov/Topic9.htm] .
known as seismic or base isolation.
For this, some pads are inserted into or under all major load-carrying elements in the base of the building which should substantially
decouple asuperstructure from itssubstructure resting on a shaking ground.The first evidence of earthquake protection by using the principle of base isolation was discovered in
Pasargadae , a city in ancient Persia, now Iran: it goes back to VI century BC. Below, there are some samples of seismic vibration control technologies of today.Earthquake protector
Heavy
damping mechanism sometimes incorporated in vibration control technologies and, particularly, inbase isolation devices may be considered a valuable source of suppressing vibrations thus enhancing a building'sseismic performance . However, for the very pliant systems such as base isolatedstructures , with a relatively low bearingstiffness but with an high damping, the so-called "damping force" may turn out the main pushing force at a strong earthquake [http://www.ecs.csun.edu/~shustov/Topic4.htm] . This finding created a theoretical ground for the new damping-disengaged base isolation technology called Earthquake Protector [https://central.nees.org/data/get/NEES-2006-0283/Public/REPORT.pdf] .A video clip of concurrent shake-table experiments with two identical and kinematically equivalent to their 12-story prototype building models is presented at [http://www.youtube.com/watch?v=kzVvd4Dk6sw] . The right model is resting on Earthquake Protectors, while the left one, caught at the time of its collapse, is fixed to the shake-table platen [https://central.nees.org/?action=DisplayProjectMain&projid=283] . At this experiment, the fundamental natural period of the building model
superstructure is about 1.2s, the isolated period of the Earthquake Protector is 5.0s, the range of theearthquake simulation periods is 0.02 - 2.00s, and the maximum ground acceleration is about 1.0g [http://www.ecs.csun.edu/~shustov/EP-2006.htm] .Tuned mass damper
Typically, the
tuned mass damper s are huge concrete blocks mounted inskyscraper s or other structures and moved in opposition to theresonance frequency oscillations of the structures by means of some sort of spring mechanism.Taipei 101 skyscraper needs to withstandtyphoon winds and earthquaketremor s common in its area of the Asia-Pacific. For this, 660 metric tons steelpendulum that serves as a tuned mass damper was designed and installed atop the structure. Suspended from the 92nd to the 88th floor, the pendulum sways to decrease resonant amplifications of lateral displacements in the building caused by earthquakes and stronggust s.Friction pendulum bearing
Friction Pendulum Bearing (FPB) is another name of Friction Pendulum System (FPS). It is based on three pillarscite book|title=A Simple Pendulum Technique for Achieving Seismic Isolation|author=Zayas, Victor A. et al.|page=p.317, Vol.6, No.2|date=1990|publisher=Earthquake Spectra|isbn=0087552930] :
* articulated friction slider;
* spherical concave sliding surface;
* enclosing cylinder for lateral displacement restraint.Snapshot with the link to video clip of a shake-table testing of FPB system supporting a rigid building model is presented at the right.
Elevated building foundation
against potentially destructive components of possible earthquakes including not just lateral tremors but vertical shaking too.
This goal can be achieved by means of a proper choice of materials, dimensions, and configuration of EBF for the particular local soil conditions.
As a result of multiple
reflection s,diffraction s, anddissipation s of the seismic waves in a process of their vertical propagation through horizontal strata of the EBF, any transmission of seismic wave energy into thesuperstructure furnished with elevated building foundation will be decreased considerably [https://central.nees.org/data/get/NEES-2006-0283/Public/EBF%20and%20EP.pdf] .eismic design
Seismic design is based on authorized engineering procedures, principles and criteria meant to
design or retrofit structures subject to earthquake exposurecite book|title= Seismic Design of Building Structures|author=Lindeburg, Michael R.; Baradar, Majid|date=2001|publisher=Professional Publications|isbn=1888577525] . However, the building design which blindly follows seismic code regulations does not guarantee safety against collapse or serious damage [http://nisee.berkeley.edu/bertero/html/earthquake-resistant_construction.html ] .The price of poor seismic design may be enormous. Nevertheless, seismic design has always been a
trial and error process no matter it was based upon physical laws or empirical knowledge of the structural performance of different shapes and materials.should, normally, pass examination on "Seismic Principles" [http://www.pels.ca.gov/applicants/plan_civseism.pdf] which, e.g. in the State of California, include:
* Seismic Data and Seismic Design Criteria
* Seismic Characteristics of Engineered Systems
* Seismic Forces
* Seismic Analysis Procedures
*Seismic Detailing and Construction Quality ControlTo build up complex structural systemscite book|title=Seismic Design Handbook|author=Edited by Farzad Naeim|date=1989|publisher=VNR|isbn=0442269226] , seismic design utilizes, mostly, the same relatively small number of basic structural elements (to say nothing of vibration control devices) as any non-seismic design project.
Normally, according to building codes, structures are designed to "withstand" the largest earthquake of a certain probability that is likely to occur at their location. This means the loss of life should be minimized by preventing collapse of the buildings.
Seismic design is carried out by understanding the possible
failure mode s of a structure and providing the structure with appropriatestrength ,stiffness andconfiguration cite book|title= Building Configuration & Seismic Design|author=Arnold, Christopher; Reitherman, Robert|date=1982|publisher=A Wiley-Interscience Publication|isbn=0471861383] to ensure those modes cannot occur.eismic design requirements
Seismic design requirements depend on the type of the structure, locality of the project and its authorities which stipulate applicable seismic design codes and criteria cite book|title= Recommended Lateral Force Requirements and Commentary|author=Seismology Committee|date=1999|publisher= Structural Engineers Association of California] . For instance,
California Department of Transportation 's requirements called "The Seismic Design Criteria" (SDC) and aimed at the design of new bridges in California [http://www.dot.ca.gov/hq/esc/earthquake_engineering/SDC/SDCPage.html] incorporate an innovativeseismic performance based approach.The most significant feature in the SDC design philosophy is a shift from a "force-based assessment" of seismic demand to a "displacement-based assessment" of demand and capacity. Thus, the newly adopted displacement approach is based on comparing the "elastic displacement" demand to the "inelastic displacement" capacity of the primary structural components while insuring a minimum level of inelastic capacity at all potential plastic hinge locations.
In addition to the designed structure itself, seismic design requirements may include a "ground stabilization" underneath the structure: sometimes, heavily shaken ground breaks up which leads to collapse of the structure sitting upon it [http://es.youtube.com/watch?v=d316Wdgf16Y&feature=PlayList&p=F297EF2ADDEAD86C&index=63] .The following topics should be of primary concerns: liquefaction; dynamic lateral earth pressures on retaining walls; seismic slope stability; earthquake-induced settlement cite book|title= Geotechnical Earthquake Engineering Handbook|author=Robert W. Day|date=2007|publisher= McGraw Hill|isbn=0713778294] .
Failure modes
Failure mode is the manner by which a failure is observed. It, generally, describes the way the failure occurs. Though costly and time consuming, learning from each real earthquake failure remains a routine recipe for advancement in "seismic design" methods. Below, some typical modes of earthquake-generated failures are presented. [
unreinforced masonry building s at earthquakes] The lack of reinforcement coupled with poor mortar and inadequate roof-to-wall ties can result in substantial damage to a unreinforced masonry building. Severely cracked or leaning walls are some of the most common earthquake damage. Also hazardous is the damage that may occur between the walls and roof or floor diaphragms. Separation between the framing and the walls can jeopardize the vertical support of roof and floor systems.of the floor above combined with the support on the two hidden sides by continuous walls, not penetrated with large doors as on the street sides, is preventing full collapse of the structure.
of structures. This caused major damage to thousands of buildings in Niigata, Japan in 1964 [http://www.youtube.com/watch?v=d316Wdgf16Y&feature=PlayList&p=F297EF2ADDEAD86C&index=63] .
: the landslide required an "earthquake trigger" before being released.
, the tower pounded against the independently vibrating adjacent building behind. A possibility of pounding depends on both buildings' lateral displacements which should be accurately estimated and accounted for.
that carried the lateral load, peeled apart because of inadequate through-ties and failed.
7-story reinforced concrete buildings on steep slope collapse due to the following:
* Improper construction site
* Poor detailing of the reinforcement ( lack of concrete confinement in the columns and at the beam-column joints, inadequate splice length)
* Weak/soft story (open space at the first floors)
* Long cantilevers with heavy loadabout 10 inches to the east on its foundation.
If a superstructure is not mounted on a base isolation system, its shifting on the basement should be prevented.
due to insufficient shear reinforcement mode which allows main reinforcement to buckle outwards. The deck unseated at the hinge and failed in shear. As a result, the La Cienega-Venice underpass section of the 10 Freeway collapsed.
[
Loma Prieta earthquake ]Loma Prieta earthquake : side view ofreinforced concrete support-columns failure and the upper deck collapse onto the lower deck of two-level Cypress viaduct of Interstate Highway 880, Oakland, CA.[
retaining wall due to ground movement, Loma Prieta] Retaining wall failure atLoma Prieta earthquake in Santa Cruz Mountains area: prominent northwest-trending extensional cracks up to 12 cm (4.7 in) wide in the concrete spillway to Austrian Dam, the north abutment. Ground shaking triggered
Loma Prietaliquefaction in a subsurface layer of sand, producing differential lateral and vertical movement in a overlyingcarapace of unliquified sand and silt. This mode of ground failure, termed lateral spreading, is a principal cause of liquefaction-related earthquake damage [http://www.youtube.com/watch?v=YlSuosOTAV0&feature=PlayList&p=660C7AFD70E81C12&index=53&playnext=2&playnext_from=PL] .which may be hazardous even without any earthquake, see video footage at [http://www.youtube.com/watch?v=uKeENdyIluI&NR=1] .
, Indonesia, triggered a series of devastating tsunamis, killing more than 225,000 people in eleven countries by inundating surrounding coastal communities with huge waves up to 30 meters (100 feet) high. For a video footage of the tsunami propagation, click on [http://www.youtube.com/watch?v=w9ygYqj4rVM&feature=PlayList&p=E386AF07A3FAA776&index=0] .
Earthquake construction
Earthquake construction means implementation of seismic design to enable building and non-building structures to live through the anticipated earthquake exposure up to the expectations and in compliance with the applicable
building code s.Design and construction are intimately related. To achieve a good workmanship, detailing of the members and their connections should be, possibly, simple. As any construction in general, earthquake construction is a process that consists of the building, retrofitting or assembling of infrastructure given the materials available cite book|title=Bridge Design, Construction and Maintenance
author=Edited by Dr. Robert Lark|date=2007|publisher=Thomas Telford|isbn=0727735934] .The destabilizing action of an earthquake on constructions may be "direct" (seismic motion of the ground) or "indirect" (earthquake-induced landslides,
soil liquefaction and waves of tsunami).A structure might have all the appearances of stability, yet offer nothing but danger when an earthquake occurs [http://www.msnbc.msn.com/id/24993357/] . The crucial fact is that, for safety, earthquake-resistant construction techniques are as important as
quality control and using correct materials. "Earthquake contractor" should beregistered in the state of the project location,bonded andinsured .To minimize possible losses, construction process should be organized with keeping in mind that earthquake may strike any time prior to the end of construction.
Each
construction project requires a qualified team of professionals who understand the basic features of seismic performance of different structures as well asconstruction management .Adobe structures
is very common in some of the world's most hazard-prone regions, traditionally across Latin America, Africa, Indian subcontinent and other parts of Asia, Middle East and Southern Europe.
Adobe buildings are considered very vulnerable at strong quakes [http://nz.youtube.com/watch?v=AOiqGHEOmuA&feature=PlayList&p=F297EF2ADDEAD86C&index=16] . However, multiple ways of seismic strengthening of new and existing adobe buildings are available, see, e.g., [http://www.world-housing.net/uploads/WHETutorial_Adobe_English.pdf] .
Key factors for the improved seismic performance ofadobe construction are:
*Quality of construction.
*Compact, box-type layout.
*Seismic reinforcement [http://nz.youtube.com/watch?v=_EUOPY0OjlQ&feature=PlayList&p=F297EF2ADDEAD86C&index=21] .Limestone and sandstone structures
masonry. They are the long-lasting materials but their rather heavy weight is not beneficial for adequate seismic performance [http://www.youtube.com/watch?v=u1Fer3yMo5I&feature=PlayList&p=F297EF2ADDEAD86C&index=45] .
Application of modern technology to seismic retrofitting can enhance the survivability of unreinforced masonry structures. As an example, from 1973 to 1989, the City and County Building, Salt Lake City, Utah was exhaustively renovated and repaired with an emphasis on preserving historical accuracy in appearance. This was done in concert with a seismic upgrade that placed the weak sandstone structure on base isolation foundation to better protect it from earthquake damage.
Timber frame structures
dates back thousands of years, and has been used in many parts of the world during various periods such as ancient Japan, Europe and medieval England in localities where timber was in good supply and building stone and the skills to work it were not.
The use of
timber framing in buildings provides their complete skeletal framing which offers some structural benefits as the timber frame, if properly engineered, lends itself to better "seismic survivability" cite book|title= Timber Design & Construction Sourcebook=Gotz, Karl-Heinz et al|date=1989|publisher=McGraw-Hall |isbn=0070238510] .Light-frame structures
s or "drag struts" to distribute shear along a diaphragm length are required.
Reinforced masonry structures
A construction system where
steel reinforcement is embedded in themortar joint s ofmasonry or placed in holes and after filled withconcrete orgrout is called reinforced masonry [http://www.staff.city.ac.uk/earthquakes/MasonryBrick/ReinforcedBrickMasonry.htm] .Devastating
1933 Long Beach earthquake revealed that masonry construction should be improved immediately. Then, the California State Code made the reinforced masonry mandatory.There are various practices and techniques to achieve reinforced masonry. The most common type is the reinforced hollow unit masonry. The effectiveness of both vertical and horizontal reinforcement strongly depends on the type and quality of the masonry, i.e. masonry units and mortar.
To achieve a
ductile behavior of masonry, it is necessary that theshear strength of the wall is greater than thetensile strength of reinforcement to ensure a kind of bending failure cite book|title= Seismic Design of Masonry Using the 1997 UBC|author= Ekwueme, Chukwuma G.; Uzarski, Joe|date=2003|publisher=Concrete Masonry Association of California and Nevada] .Reinforced concrete structures
s, floors or bridges.
Prestressed concrete is a kind ofreinforced concrete used for overcoming concrete's natural weakness in tension. It can be applied tobeams , floors or bridges with a longer span than is practical with ordinary reinforced concrete. Prestressingtendon s (generally of high tensile steel cable or rods) are used to provide a clamping load which produces acompressive stress that offsets thetensile stress that the concretecompression member would, otherwise, experience due to a bending load.To prevent catastropic collapse in response earth shaking (in the interest of life safety), a traditional reinforced concrete frame should have
ductile joints. Depending upon the methods used and the imposed seismic forces, such buildings may be immediately usable, require extensive repair, or may have to be demolished. [http://www.youtube.com/watch?v=3z4YLUqOysI&feature=related] .Prestressed structures
Prestressed structure is the one whose overallintegrity ,stability andsecurity depend, primarily, on a "prestressing". "Prestressing" means the intentional creation of permanent stresses in a structure for the purpose of improving its performance under various service conditionscite book|title= Design of Prestressed Concrete|author=Nilson, Arthur H.|date=1987|publisher=John Wiley & Sons|isbn=0471830720] .There are the following basic types of prestressing:
*Pre-compression (mostly, with the own weight of a structure)
*Pretensioning with high-strength embedded tendons
*Post-tensioning with high-strength bonded or unbonded tendons [ [http://www.seaint.org/seaocconvention/convention1999/Proceedings/BP_Shield.pdf Sail-Rigging Blast-Protective Structural Shield] ] of buildings.A beneficial idea of "prestressing" was, apparently, familiar to the ancient Rome architects; look, e.g., at the tall
attic wall ofColosseum working as apress for the wallpier s beneath.teel structures
Steel structures are considered, mostly, earthquake resistant but their resistance should never be taken for granted [http://www.youtube.com/watch?v=3KVg5kljuU0&feature=PlayList&p=F297EF2ADDEAD86C&index=65] .
[
thumb|340_×_512_px|right|Collapsed_section_of_the_San Francisco – Oakland Bay Bridge in response toLoma Prieta earthquake ] Thus, a great number of welded steel moment frame buildings, which looked earthquake-proof, surprisingly experienced brittle behavior and were hazardously damaged in the1994 Northridge earthquake . After that,FEMA initiated development of repair techniques and new design approaches to minimize damage to steel moment frame buildings in future earthquakes [http://www.sacsteel.org/index.html] .For
structural steel seismic design based onLoad and Resistance Factor Design (LRFD) approach, it is very important to assess ability of a structure to develop and maintain its bearing resistance in theinelastic range. A measure of this ability isductility , which may be observed in a "material itself", in a "structural element", or to a "whole structure".As a consequence of
Northridge earthquake experience, all pre-qualified connection details and design methods contained in the building codes of that time have been rescinded. The new provisions stipulated that new designs be substantiated by testing (see, e.g., [http://www.youtube.com/watch?v=6ypwtfXIPK8&feature=PlayList&p=F297EF2ADDEAD86C&index=118 ] ) or by use of test-verified calculations.Prediction of earthquake losses
Earthquake loss estimation is usually performed in terms of a "Damage Ratio" (DR) which is a ratio of the earthquake damage dollar amount to
total value of a buildingcite book|title= Financial Management of Earthquake Risk|author=EERI Endowment Subcommittee|date=May 2000|publisher=EERI Publication|isbn=0943198216] . For a long time, it was associated with a collection of mass inventory data and was based, mostly, on experts' opinions. It looked, therefore, more like an art than a science. of facilities [http://www.ecs.csun.edu/~shustov/Topic8.htm] .There is, also, the "Damage Ratio Charts Method" which is based on a consistent quantitative analysis targeting a prediction of "damage ratios" and employs a limited number of well-understood structural and earthquake related parameters cite book|title= Future Seismic Codes and Earthquake Insurance, Proc. 66th Annual SEAOC Convention, San Diego, CA|author=Shustov, V.|date=1997|publisher=SEAOC] . It establishes a direct theoretical relationship between the standard
structural design procedure and the expected damage characteristics required byinsurers . The method isuser-friendly : its application, supported by a site-specific evaluation, does not take more than a few days.hakeZone for kids
web-site at [http://www.fema.gov/kids/quake.htm] . It offers:
* Earthquake fact or fiction
* Home hazard hunt
* Historic earthquakes
* Tasty quake
* Map of earthquake-risk states
* Earthquake disaster math
* Disaster intensity scales
* Water, wind, and earth game, and
* Earthquake legendsIt includes, also, some safety things to know and how to protect your pets and home from disasters.
More advanced information including video clips of real testing events is presented at the
CSUN 's ShakeZone for kids portal at [http://www.ecs.csun.edu/~shustov/ShakeZone.htm] . Funny videos ofearthquake simulation may be found at [http://tw.youtube.com/watch?v=UcgRtZKRip0] and an impressive footage of tsunami at [http://www.youtube.com/watch?v=WOw151ElhvM&feature=PlayList&p=E386AF07A3FAA776&index=1] .ee also
*
Earthquake engineering structures
*Earthquake performance evaluation
*Seismic retrofit
*Wind engineering
*Explosion protection
* [http://www.latimes.com/news/local/la-quake-special,0,3322877.special Earthquake Special]Notes