Passive house

Passive house

The term passive house ("Passivhaus" in German) refers to the rigorous, voluntary, Passivhaus standard for energy use in buildings. It results in ultra-low energy buildings that require little energy for space heating or cooling. [ [http://www.passivhaustagung.de/Passive_House_E/passivehouse_definition.html Definition of Passive House] ] A similar standard, "MINERGIE-P", is used in Switzerland [ [http://www.minergie.ch/fr/index.php?standards-6 Minergie-Standard] ] . The standard is not confined only to houses. Several office buildings, schools, kindergartens and a supermarket have also been constructed to the standard. Passive design is not the attachment or supplement of architectural design, but an integrated design process with the architectural design.Ji Yan and Plainiotis Stellios (2006): Design for Sustainability. Beijing: China Architecture and Building Press. ISBN 7-112-08390-7] Although it is mostly applied to new buildings, it has also been used for refurbishments.

The first Passivhaus buildings were built in Darmstadt, Germany, in 1990, and occupied the following year. In September 1996 the "Passivhaus-Institut" was founded in Darmstadt to promote and control the standard. Since then, more than 6,000 Passivhaus buildings have been constructed in Europe, [ [http://www.passivhaustagung.de/elfte/english/01_start_home.html Passive House Conference] ] most of them in Germany and Austria, with others in various countries world-wide. In North America the first Passivhaus was built in Urbana, Illinois in 2003, [ [http://www.e-colab.org/ecolab/SmithHouse.html First US Passive House] ] and the first to be certified was built at Waldsee, Minnesota, in 2006. [ [http://www.waldseebiohaus.typepad.com/ Certified US Passive House] ]

Origins of the passive house

The Passive House standard originated from a conversation in May 1988 between Professors Bo Adamson of Lund University, Sweden, and Wolfgang Feist of the "Institut für Wohnen und Umwelt" (Institute for Housing and the Environment [ [http://www.iwu.de/homep_e.htm Institute for Housing and the Environment] ] ). Their concept was developed through a number of research projects [ [http://www.passivhaustagung.de/Kran/First_Passive_House_Kranichstein_en.html Evaluation of the First Passive House] ] , aided by financial assistance from the German state of Hesse. The eventual building of four row houses (terraced houses) was designed for four private clients by architects professor Bott, Ridder and Westermeyer.

After the concept had been validated at Darmstadt, with space heating 90% less than required for a standard new building of the time, the 'Economical Passive Houses Working Group' was created in 1996. This developed the planning package and initiated the production of the novel components that had been used, notably the windows and the high-efficiency ventilation systems. Meanwhile further passive houses were built in Stuttgart (1993), Naumburg, Hesse, Wiesbaden, and Cologne (1997) [ [http://www.buildingforafuture.co.uk/winter05/1-29.pdf European Continental Passive Houses ] ] .

The products developed for the Passivhaus were further commercialised during and following the European Union sponsored CEPHEUS project, which proved the concept in 5 European countries over the winter of 2000-2001.

While some techniques and technologies were specifically developed for the standard, others (such as superinsulation) were already in existence, and the concept of passive solar building design dates back to antiquity. There was also experience from other low-energy building standards, notably the German "Niedrigenergiehaus" (low-energy house) standard, as well as from buildings constructed to the demanding energy codes of Sweden and Denmark.

The standard

The Passivhaus standard requires that the building fulfills the following requirements: [ [http://www.cepheus.de/eng/index.html Passive House Requirements] ]

* The building must not use more than 15 kWh/ per year (4746 btu/ft² per year) in heating energy.
* With the building de-pressurised to 50 Pa (N/) below atmospheric pressure by a blower door, the building must not leak more air than 0.6 times the house volume per hour (n50 ≤ 0.6 / hour).
* Total primary energy consumption (primary energy for heating, hot water and electricity) must not be more than 120 kWh/m² per year (3.79 × 104 btu/ft² per year)
* Further, the specific heat load for the heating source at design temperature is recommended, but not required, to be less than 10 W/m² (3.17 btu/ft² per hour).

These standards are much higher than houses built to most normal building codes. For comparisons, see the international comparisons section below.

National partners within the 'consortium for the Promotion of European Passive Houses' are thought to have some flexibility to adapt these limits locally. [ [http://www.europeanpassivehouses.org/ europeanpassivehouses(PEP)] ]

pace heating requirement

By achieving the Passivhaus standards, qualified buildings are able to dispense with conventional heating systems. While this is an underlying objective of the Passivhaus standard, some type of heating will still be required and most Passivhaus buildings do include a system to provide supplemental space heating. This is normally distributed through the low-volume heat recovery ventilation system that is required to maintain air quality, rather than by a conventional hydronic or high-volume forced-air heating system, as described in the space heating section below.

Construction costs

In Passivhaus buildings, the cost savings from dispensing with the conventional heating system can be used to fund the upgrade of the building envelope and the heat recovery ventilation system. With careful design and increasing competition in the supply of the specifically designed Passivhaus building products, in Germany it is now possible to construct buildings for the same cost as those built to normal German building standards, as was done with the Passivhaus apartments at Vauban, Freiburg [ [http://www.passivhaus-vauban.de/passivhaus.en.html Cost Efficient Apartment Passive House] ] .

Evaluations have indicated that while it is technically possible, the costs of meeting the Passivhaus standard increase significantly when building in Northern Europe above 60° latitude [ [http://erg.ucd.ie/pep/pdf/Henk_Kaan.pdf Passive Houses in High Latitudes] ] [ [http://erg.ucd.ie/pep/pdf/Tor_Helge_Dokka.pdf Passive Houses in Norway] ] .

Design and construction

Achieving the major decrease in heating energy consumption required by the standard involves a shift in approach to building design and construction. Design is carried out with the aid of the 'Passivhaus Planning Package' (PHPP) [ [http://www.passiv.de/07_eng/phpp/PHPP2004.htm Passivhaus Planning Package] ] , and uses specifically designed computer simulations.

To achieve the standards, a number of techniques and technologies are used in combination:

Passive solar design

Following passive solar building design techniques, where possible buildings are compact in shape to reduce their surface area, with windows oriented towards the equator (south in the northern hemisphere and north in the southern hemisphere) to maximize passive solar gain. However, the use of solar gain is secondary to minimizing the overall energy requirements.

Passive houses can be constructed from dense or lightweight materials, but some internal thermal mass is normally incorporated to reduce summer peak temperatures, maintain stable winter temperatures, and prevent possible over-heating in spring or autumn before normal solar shading becomes effective.

uperinsulation

Passivhaus buildings employ superinsulation to significantly reduce the heat transfer through the walls, roof and floor compared to conventional buildings. A wide range of thermal insulation materials can be used to provide the required high R-values (low U-values, typically in the 0.10 to 0.15 W/(m².K) range). Special attention is given to eliminating thermal bridges.

A disadvantage resulting from the thickness of wall insulation required is that, unless the external dimensions of the building can be enlarged to compensate, the internal floor area of the building may be less compared to traditional construction.

In Sweden, to achieve passive house standards, the insulation thickness would be 335 mm (about 13 in) (0.10 W/(m².K)) and the roof 500 mm (about 20 in) (U-value 0.066 W/(m².K)).

Advanced window technology

To meet the requirements of the Passivhaus standard, windows are manufactured with exceptionally high R-values (low U-values, typically 0.85 to 0.70 W/(m².K) for the entire window including the frame). These normally combine triple-pane insulated glazing (with a good solar heat-gain coefficient, low-emissivity coatings, argon or krypton gas fill, and 'warm edge' insulating glass spacers) with air-seals and specially developed thermally-broken window frames.

In Central Europe, for unobstructed south-facing Passivhaus windows, the heat gains from the sun are, on average, greater than the heat losses, even in mid-winter.

Airtightness

Building envelopes under the Passivhaus standard are required to be extremely airtight compared to conventional construction. Air barriers, careful sealing of every construction joint in the building envelope, and sealing of all service penetrations through it are all used to achieve this.

Airtightness minimizes the amount of warm (or cool) air that can pass through the structure, enabling the mechanical ventilation system to recover the heat before discharging the air externally.

Ventilation

Mechanical heat recovery ventilation systems, with a heat recovery rate of over 80% and high-efficiency electronically commutated (ECM) motors, are employed to maintain air quality, and to recover sufficient heat to dispense with a conventional central heating system. Since the building is essentially airtight, the rate of air change can be optimized and carefully controlled at about 0.4 air-changes per hour. All ventilation ducts are insulated and sealed against leakage.

Although not compulsory, earth warming tubes (typically ≈200 mm (~7,9 in) diameter, ≈40 m (~130 ft) long at a depth of ≈1.5 m (~5 ft)) are often buried in the soil to act as earth-to-air heat exchangers and pre-heat (or pre-cool) the intake air for the ventilation system. In cold weather the warmed air also prevents ice formation in the heat recovery system's heat exchanger.

Alternatively, an earth to air heat exchanger, can use a liquid circuit instead of an air circuit, with a heat exchanger (battery) on the supply air. This avoids the risk of condensation, mold growth and associated health risks with the earth warming tubes.

pace heating

In addition to using passive solar gain, Passivhaus buildings make extensive use of their intrinsic heat from internal sources – such as waste heat from lighting, white goods (major appliances) and other electrical devices (but not dedicated heaters) – as well as body heat from the people and animals inside the building. Together with the comprehensive energy conservation measures taken, this means that a conventional central heating system is not necessary, although they are sometimes installed due to client scepticism.

Instead, Passive houses sometimes have a dual purpose 800 to 1,500 Watt heating and/or cooling element integrated with the supply air duct of the ventilation system, for use during the coldest days. It is fundamental to the design that all the heat required can be transported by the normal low air volume required for ventilation. A maximum air temperature of 50 °C (122 °F) is applied, to prevent any possible smell of scorching from dust that escapes the filters in the system.

The air-heating element can be heated by a small heat pump, by direct solar thermal energy, annualized geothermal solar, or simply by a natural gas or oil burner. In some cases a micro-heat pump is used to extract additional heat from the exhaust ventilation air, using it to heat either the incoming air or the hot water storage tank. Small wood-burning stoves can also be used to heat the water tank, although care is required to ensure that the room in which stove is located does not overheat.

Beyond the recovery of heat by the heat recovery ventilation unit, a well designed Passive house in the European climate should not need any supplemental heat source if the heating load is kept under 10W/m² [ [http://www.passivhaustagung.de/zehnte/englisch/texte/PEP-Info1_Passive_Houses_Kronsberg.pdf Passive House Estate in Hannover-Kronsberg p72] ] .

Because the heating capacity and the heating energy required by a passive house both are very low, the particular energy source selected has fewer financial implications than in a traditional building, although renewable energy sources are well suited to such low loads.

Lighting and electrical appliances

To minimize the total primary energy consumption, low-energy lighting (such as compact fluorescent lamps), and high-efficiency electrical appliances are normally used.

Quality of life

By their design, passive houses usually have the following traits:
*the air is fresh, and very clean. Note that for the parameters tested, and provided the filters (minimum F6) are maintained, HEPA quality air is provided. 0.3 air changes per hour (ACH) are recommended, otherwise the air can become "stale" (excess CO2, flushing of indoor air pollutants) and any greater, excessively dry (lack of humidity <40%). This implies careful selection of interior finishes and furnishings, to minimize indoor air pollution from formaldehydes, VOC's, etc. The use of a mechanical venting system also implies higher positive ion values. This can be counteracted somewhat via opening the window for a very brief time, plants and indoor fountains. However, it should be noted that failure to exchange air with the outside during occupied periods is not advisable.
*because of the high resistance to heat flow (high R-value insulation), there are no "outside walls" which are colder than other walls.
*since there are no radiators, there is more space on the rooms' walls.
*inside temperature is homogeneous; it is impossible to have single rooms (e.g. the sleeping rooms) at a different temperature from the rest of the house. Note that the relatively high temperature of the sleeping areas is physiologically not considered desirable by some building scientists. Bedroom windows can be cracked slightly to alleviate this when necessary.
*the temperature changes only very slowly - with ventilation and heating systems switched off, a passive house typically loses less than 0.5 °C (1 °F) per day (in winter), stabilizing at around 15 °C (59 °F) in the central European climate.
*opening windows for a short time only has a very limited effect - after the windows are closed, the air very quickly returns to the "normal" temperature.

International comparisons

*In the United States, a house built to the Passive House standard results in a building that requires space heating energy of 1 BTU per square foot per heating degree day, compared with about 5 to 15 BTUs per square foot per heating degree day for a similar building built to meet the 2003 Model Energy Efficiency Code. This is between 75 and 95% less energy for space heating and cooling than current new buildings that meet today's US energy efficiency codes. The Passivhaus in the German Language Village, Waldsee, in Minnesota uses 85% less energy than a house built to Minnesota building codes. [ [http://waldseebiohaus.typepad.com/biohaus/design.html Waldsee BioHaus design] ]
*In the United Kingdom, an average new house built to the Passive House standard would use 77% less energy for space heating, compared to the Building Regulations. [ [http://erg.ucd.ie/pep/pdf/Energy_Saving_Potential_2.pdf Energy Saving Potential of Passive Houses in the UK] ]
*In Ireland, it is calculated that a typical house built to the Passive House standard instead of the 2002 Building Regulations would consume 85% less energy for space heating and cut space-heating related carbon emissions by 94%. [ [http://erg.ucd.ie/pep/pdf/Irena_Kondratenko.pdf Passive Houses in Ireland] ]

Comparison with zero energy buildings

A net zero-energy building (ZEB) is a term for a related approach to creating buildings that use substantially less energy. A ZEB requires the use of onsite renewable energy technologies like photovoltaic rather than optimising the buildings fabric heat loss to offset the building's primary energy use.

ee also

*CEPHEUS
*Energy-plus buildings
*Low-energy buildings
*List of low-energy building techniques
*Renewable heat
*Self-sufficient homes
*Thermal conductivity for an explanation of how thermal conductivity, thermal conductance, and thermal resistance are related

References

External links

Passive House information

* [http://www.passivhaustagung.de/Kran/First_Passive_House_Kranichstein_en.html History of the Passivhaus]
* [http://www.passivhaustagung.de/zehnte/englisch/texte/PEP-Info1_Passive_Houses_Kronsberg.pdf Passive House Estate in Hannover-Kronsberg] (4.3MB) Construction details and performance
* [http://www.passivehouse.com/07_eng/news/CEPHEUS_final_long.pdf CEPHEUS Final Report] (5MB) Major European Union research project. Technical report on as-built thermal performance.
* [http://www.passive-on.org "Passive-On Project"] Research and dissemination to promote Passive Houses in warm climates.
* [http://www.passivehouse.us Passive House Institute US] Promotion and certification of Passive House construction in North America.
* [http://passivhuscentrum.se/startsida.html?&L=1 Passivhuscentrum] the Swedish Passive House Center in Alingsås (in English)

Passive House examples

* [http://www.passivehouse.com/English/Kranichstein.HTM The original Darmstadt Passive Houses]
* [http://www.passivhaustagung.de/Passive_House_E/Examples_passive_houses.html German & Austrian residential Passive House examples]
* [http://www.passivehouse.co.uk/content/view/18/91/ Ty-Kama House] , One of the first Passive Houses in the United Kingdom.
* [http://www.granback.se/welcome-to-passiv-house-granback Passive house Granbäck, Sweden] Stockholms first passive house
* [http://www.kjellgrenkaminsky.se/index.php?blp=25 Prefabricated Passive House examples, Sweden]


Wikimedia Foundation. 2010.

Игры ⚽ Нужно сделать НИР?

Look at other dictionaries:

  • Passive cooling — refers to technologies or design features used to cool buildings without power consumption, such as those technologies discussed in the Passive house project.Passive coolingThe term passive implies that energy consuming mechanical components like …   Wikipedia

  • Passive — is the opposite of active. It has several specific meanings:* Passive voice of a verb * Passivation is the formation of a non reactive surface film that inhibits further corrosion of a metal * Passive components in electronics * Passive mode in… …   Wikipedia

  • Passive solar building design — Elements of passive solar design, shown in a direct gain application …   Wikipedia

  • House Energy Rating — A House Energy Rating is an index of energy efficiency for residential homes in Australia. The Australian Building Codes Board introduced energy efficiency measures for houses into the Building Code of Australia (BCA) on 1 January 2003. It has… …   Wikipedia

  • Passive smoking — is the involuntary inhalation of smoke from tobacco products. It occurs when tobacco smoke permeates any environment, causing its inhalation by all people within that environment. Such smoke is called secondhand smoke (SHS) or environmental… …   Wikipedia

  • House R 128 — (Sobek House) is a futuristic single family house in Stuttgart, Germany, built by architect Werner Sobek in 1999/2000.The house features a modular and recyclable design, iscompletely glazed and has no interior dividing walls.It is computerized… …   Wikipedia

  • passive — I. adjective Etymology: Middle English, from Latin passivus, from passus, past participle Date: 14th century 1. a. (1) acted upon by an external agency (2) receptive to outside impressions or influences b. (1) asserting that the grammatical… …   New Collegiate Dictionary

  • House — For other uses, see House (disambiguation). A traditional house in Novosibirsk, Siberia, Russia …   Wikipedia

  • house */*/*/ — I UK [haʊs] / US noun Word forms house : singular house plural houses UK [ˈhaʊzɪz] / US [ˈhaʊzəz] 1) a) [countable] a building for living in, usually where only one family lives I d love a house with a garden. a three bedroom house move house (=… …   English dictionary

  • house — house1 [ haus ] (plural houses [ hauzəz ] ) noun *** ▸ 1 building for living in ▸ 2 company/organization ▸ 3 restaurant/hotel etc. ▸ 4 area for audience ▸ 5 type of music ▸ 6 used in building names ▸ 7 old important family ▸ + PHRASES 1. ) count… …   Usage of the words and phrases in modern English

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”