Fire department rehab

Fire department rehab

Fire department rehab is a vital firefighting service on the fireground, providing firefighters and other emergency personnel with immediate medical attention including rehydration, treatment for smoke inhalation, and the prevention of such life-threatening conditions as heatstroke and heart attack.

Equipment

Rehab equipment includes but is not limited to:
*A canopy
*Misting fans for cooling
*Coolers with water and other beverages
*Medical monitoring
*Chairs
*Food

Overview

Firefighter rehab is designed to ensure that the physical and mental well-being of members operating at the scene of an emergency (or a training exercise) don't deteriorate to the point where it affects the safety of any other members. Figherfighting is inherently dangerous in the best of circumstances, and any additional physical or mental stress increases the danger.

In 1993, the US Coast Guard conducted a study dealing with the effects of interior firefighting on the human body.Fact|date=August 2008 The researchers noted that the figherfighter's body core temperature often reaches 104 degrees Fahrenheit during the firefight, even after short exposures.

*1. Primary Mission:

: The primary mission for fire command is to identify, examine, and evaluate the physical and mental status of fire-rescue personnel who have been working during the emergency incident or a training exercise. Following a proper survey (see below), it should be determined what additional treatment, if any, may be required.

: According to FEMA, "Any activity/incident that is large in size, long in duration, and/or labor intensive will rapidly deplete the energy and strength of personnel and there merits consideration for rehabilitation."

* 2. Launching The Rehab Operation

: A specially designated Rehab Area, (or Group) remote from the fire or emergency incident, should be established at the discretion of the Incident Commander in consult with the senior Fire Safety Officer. If the Incident Commander determines that Rehab is necessary, qualified Paramedics or EMTs (assigned to the first alarm response) should be designated to manage the Rehab Sector under the command of a fire or EMS officer or supervisor.

: Note the emphasis of the "first alarm response." EMS personnel must be on scene and available to provide treatment to fireground personnel at a moment's notice. If EMS does not respond as part of the initial turnout, consideration should be given to the fact that OSHA will certainly question why they weren't... especially if anyone is injured.

: Because they work side by side with the front line troops, company officers play an important role in Rehab. In fact, the federal government suggests that the safety of the fireground rests here, at the supervisor level. If a company member shows signs of fatigue or illness, the company officer will likely be the first to recognize the problem.

: Anticipate Rehab needs early in the incident. During large-scale operations, Incident Command should consider augmenting existing resources by requesting additional EMS personnel or even another engine company or squad, to assist in the operation of the Rehab Sector.

*3. Locating the Rehab Sector:

: It is crucial for Command to establish The Rehab Sector away from any environmental hazards, or by-products of the fire, such as smoke, gases or fumes. During hot months, the ideal location might include a shady, cool area distant from the incident. In winter, a warm, dry area is preferred. Regardless of the season, the area should be readily accessible to EMS-Rescue personnel and their equipment, so they may restock the sector with supplies, or in the event that ambulance transport is required.

: Rehab sites can also be established in the lobbies of nearby buildings, a parking lot, or even inside municipal buses.

: Misting/cooling systems, heating systems, SCBA refilling and canteen service should be stationed in or around this area as well. During large-scale incidents, like multi-alarm fires, Command should consider establishing Multiple Rehab Areas as the situation warrants.

*4. Coordination and Manning:

:Command of the Rehab Area should be assigned to a fire chief or company level officer, who is designated as the Rehab Officer under most Incident Command structures. The incident itself will determine just how many people you'll need to do the job, however a minimum of two trained EMS personnel should initially be assigned to monitor and assist firefighters in the Rehab Sector. Utilize volunteer canteen or auxiliary members to assist EMS personnel in making "working" members as comfortable as possible.

*5. Evaluation of Fire-Rescue Personnel:

: It is important for command and company level officers to continually monitor personnel for telltale signs of exhaustion, stress, and or physical trauma. Individual members are encouraged to report to the Rehab Sector at any time that he or she feels the need to do so. Symptoms may include weakness, dizziness, chest pain, muscle cramps, nausea, altered mental status, difficulty breathing, and others.

: Regardless of physical well-being, all fireground personnel should report to the Rehab Sector immediately following:

: a. Strenuous Activity - Forcible Entry, Advancing Hoselines, Ventilation, etc.: b. The use and depletion of two SCBA bottles: c. Thirty (30) minutes of operation within a hazardous/dangerous environment: d. Failure of SCBA

*6. Examination of Arriving Personnel

: Arriving personnel should be examined by qualified EMS, who should check and evaluate vital signs
, and make proper disposition, i.e. return to duty, continued rehabilitation, or transport to medical facility for treatment. The workup should include:

: a. Scoring for Glasgow coma trauma scale.: b. Checking Pupils : c. Checking Vital Signs, such as blood pressure, pulse, breathing rate,: d. Checking lung sounds : e. Administration of a 2-lead EKG, when chest pain or irregular heartbeat is presented: f. Skin condition and color: g. Body core temperature

: Heart rate should be measured as early as possible in the rest period. If the firefighter's heart rate exceeds 110 beats per minute, it is recommended that an oral temperature be taken. If body core temperature exceeds 100.6F, the firefighter should not be permitted to wear protective equipment or re-enter the active work environment, until temperature has been reduced and heart rate decreased.

: It is recommended that re-examination occur at ten minute intervals. Using standing orders or existing protocol, Rehab Team Members should record examination results on medical evaluation forms as indicated by the local jurisdiction.

*7. Treatment During Rehab:

: Upon completing the physical examination, the following steps should be taken to minimize further risk to fire-rescue personnel:

: Turnout gear, helmets, masks and hoods should be removed immediately. Prior to ingesting anything orally, fluid or solid, it is recommended that the firefighter clean his/her hands and face with water and a cleaning agent, as provided by Rehab Sector personnel.

: a. The firefighter should rehydrate (ORT): b. Oral rehydration and nutrition is recommended in the form of 1-2 quarts of fluids over a span of 15 minutes.: c. Body core temperature should be reduced by cooling the body.: d. Cool body temperatures gradually using misting systems, fans, etc.: e. Individuals should be offered Oxygen therapy via nasal cannula or O2 mask. (humidified or Nebulized).: f. Standing rest before reporting for further assignments: g. The firefighter will only report to manpower staging when presentation is deemed normal by the attending EMS personnel.

: Note: According to FEMA, Water is the best rehydration agent, however some agencies suggest a rehydration solution of 50 / 50 mixture of water and a commercially prepared activity beverage administered at about 40F. Avoid cooling the body using ice packs or hosestreams. Cooling should be gradual, limiting further shock to the body.

: In the event that presentation appears abnormal, the Firefighter should immediately receive additional treatment, especially if conditions persist following fifteen minutes of rest. As is appropriate in most locales, those complaining of chest pain, difficulty breathing and altered mental status must receive immediate ALS treatment and transport to definitive health care. Follow your local jurisdiction's ALS protocols in this event.

*8. Accountability.

: Members reporting to the Rehab Sector / Group should enter and exit the area as a team. Their company designation, number of personnel, and the times of entry to and exit from the Rehab Area should be documented. This can be done either by the Rehab Officer or his / her designee on a Company Check-In / Out Sheet. Keep crews together, and don't allow overanxious members to freelance the event.

*9. The Vital Importance Of Firefighter Rehab

: Very few firefighters who wear the badge are athletes. But from the moment the alarm is sounded, and that first surge of adrenaline reaches the heart, we're asking our bodies to work triple overtime. Couple that with 55 pounds of business suit, 1200 degree temperatures and another 50 pounds of hand tools and equipment, and the importance of effective rehabilitation at the fire scene becomes crystal clear.

: reposted with permission from the author: Lou Angeli

Personnel

Some fire departments run their own fireground rehab, or it may be provided by:
*Private non-profit organizations, such as so-called fire buffs [http://www.ifba.org/] (not to be confused with firebugs or arsonists), sparkies [http://www.legeros.com/fire/buff.shtml] and other organizations
*Emergency medical services (EMS)
*Rehab services run by private individuals

Vehicles

*Dedicated Rehab Vehicles
*Converted ambulances
*Converted step vans [http://www.buyastepvan.com/types.html (types of step vans)]
*Converted canteen trucks
*Converted buses.
*Pickup trucks

ee also

* Firefighting
* Glossary of firefighting terms

External links

* [http://www.usfa.dhs.gov/about/media/2005releases/060205.shtm Emergency Incident Rehabilitation]
* [http://www.rehabfive.org Community Service Emergency Rehab (Rehab 5)]
* [http://www.firecanteen.org Passaic County-wide Fire Rehab]
* [http://www.pcfire.org County-wide Fire Rehab and Canteen]


Wikimedia Foundation. 2010.

Игры ⚽ Нужна курсовая?

Look at other dictionaries:

  • Jersey City Fire Department — The Jersey City Fire Department (JCFD) Established September 21, 1829 Staffing Career Strength 550 uniformed 50 civilian …   Wikipedia

  • Buffalo Fire Department — Motto: Ut Vivant Alii Established 07/01/1880 Staffing Career Stre …   Wikipedia

  • Charlotte Fire Department — Established August 1, 1887 Staffing Career Strength 256 (Daily) …   Wikipedia

  • Cy-Fair Volunteer Fire Department — Cy Fair Vol. Fire Dept. Motto: Saving Lives Protecting Property Established 1962 Staffing Combination Strength 500+ (300+ volunteers 200+ paid staff) Stations …   Wikipedia

  • Pottstown Fire Department — The Pottstown Fire Department is a combination volunteer/career fire and rescue service operated by the Borough of Pottstown, Pennsylvania. It consists of four volunteer fire departments with career paid firefighter/drivers at each station to… …   Wikipedia

  • Miami Fire Department — Miami Fire Rescue Department Motto:  Excellence through Service Established July 17, 1898 Staffing Career Strength 545 Stations 14 …   Wikipedia

  • Auxiliary fire department — Auxiliary fire departments are found throughout the United States, mostly in larger cities with origins in the Civil Defense preparation of the Cold War. These departments are usually overseen by local emergency management organizations (formerly …   Wikipedia

  • Fire Services in York Region — OverviewFire services in York Region are provided for and by each municipality. There are 35 fire stations across the region. Most services consist of full time members, but some services have volunteer firefighters.The departments in south York… …   Wikipedia