Deformable mirror (DM) represents the most convenient tool for wavefront control and correction of optical aberrations. Deformable mirrors are used in combination with wavefront sensors and real-time control systems in adaptive optics. They are also finding a new use in femtosecond pulse shaping [1].

The shape of the DM can be controlled with a speed that is appropriate for compensation of dynamic aberrations present in the optical system. In practice the DM shape should be changed much faster than the process to be corrected, as the correction process, even for a static aberration, may take several iterations.

A DM usually has many degrees of freedom. Typically, these degrees of freedom are associated with the mechanical actuators and it can be roughly taken that one actuator corresponds to one degree of freedom.

Contents

Deformable mirror parameters

Number of actuators determines the number of degrees of freedom (wavefront inflections) the mirror can correct. It is very common to compare an arbitrary DM to an ideal device that can perfectly reproduce wavefront modes in the form of Zernike polynomials. For predefined statistics of aberrations a deformable mirror with M actuators can be equivalent to an ideal Zernike corrector with N (usually N < M) degrees of freedom. For correction of the atmospheric turbulence, elimination of low-order Zernike terms usually results in significant improvement of the image quality, while further correction of the higher-order terms introduces less significant improvements. For strong and rapid wavefront error fluctuations such as shocks and wake turbulence typically encountered in high-speed aerodynamic flowfields, the number of actuators, actuator pitch and stroke determine the maximum wavefront gradients that can be compensated for.

Actuator pitch is the distance between actuator centers. Deformable mirrors with large actuator pitch and large number of actuators are bulky and expensive.

Actuator stroke is the maximum possible actuator displacement, typically in positive or negative excursions from some central null position. Stroke typically ranges from ±1 to ±10 micrometres. Free actuator stroke limits the maximum amplitude of the corrected wavefront, while the inter-actuator stroke limits the maximum amplitude and gradients of correctable higher-order aberrations.

Influence function is the characteristic shape corresponding to the mirror response to the action of a single actuator. Different types of deformable mirrors have different influence functions, moreover the influence functions can be different for different actuators of the same mirror. Influence function that covers the whole mirror surface is called a "modal" function, while localized response is called "zonal".

Actuator coupling shows how much the movement of one actuator will displace its neighbors. All "modal" mirrors have large cross-coupling, which in fact is good as it secures the high quality of correction of smooth low-order optical aberrations that usually have the highest statistical weight.

Response time shows how quickly the mirror will react to the control signal. Can vary from microseconds (MEMS mirrors) to tens of seconds for thermally controlled DM's.

Hysteresis and creep are nonlinear actuation effects that decrease the precision of the response of the deformable mirror. For different concepts, the hysteresis can vary from zero (electrostatically-actuated mirrors) to tens of percent for mirrors with piezoelectric actuators. Hysteresis is a residual positional error from previous actuator position commands, and limits the mirror ability to work in a feedforward mode, outside of a feedback loop.

Deformable mirror concepts

Segmented concept mirrors are formed by independent flat mirror segments. Each segment can move a small distance back and forth to approximate the average value of the wavefront over the patch area. Normally these mirrors have little or zero cross-talk between actuators. Stepwise approximation works poorly for smooth continuous wavefronts. Sharp edges of the segments and gaps between the segments contribute to light scattering, limiting the applications to those not sensitive to scattered light. Considerable improvement of the performance of the segmented mirror can be achieved by introduction of three degrees of freedom per segment: piston, tip and tilt. These mirrors require three times more actuators than piston segmented mirrors and they suffer from diffraction on the segment edges. This concept was used for fabrication of large segmented primary mirrors for the Keck telescopes.

Continuous faceplate concept mirrors with discrete actuators are formed by the front surface of a thin deformable membrane. The shape of the plate is controlled by a number of discrete actuators that are fixed to its back side. The shape of the mirror depends on the combination of forces applied to the faceplate, boundary conditions (the way the plate is fixed to the mirror) and the geometry and the material of the plate. These mirrors are often the most desirable implementation, as they allow smooth wavefront control with very large - up to several thousands - degrees of freedom.

MEMS concept mirrors are fabricated using bulk and surface micromachining technologies. MEMS mirrors have a great potential to be cheap. They can break the high price threshold of conventional adaptive optics. MEMS mirrors typically have high response rates, high precision and have no hysteresis, unlike other types of deformable mirrors.

Membrane concept mirrors are formed by a thin conductive and reflective membrane stretched over a solid flat frame. The membrane can be deformed electrostatically by applying control voltages to electrostatic electrode actuators that can be positioned under or over the membrane. If there are any electrodes positioned over the membrane, they are transparent. It is possible to operate the mirror with only one group of electrodes positioned under the mirror. In this case a bias voltage is applied to all electrodes, to make the membrane initially spherical. The membrane can move back and forth with respect to the reference sphere.

Bimorph concept mirrors are formed by two or more layers of different materials. One or more of (active) layers are fabricated from a piezoelectric or electrostrictive material. Electrode structure is patterned on the active layer to facilitate local response. The mirror is deformed when a voltage is applied to one or more of its electrodes, causing them to extend laterally, which results in local mirror curvature. Bimorph mirrors are rarely made with more than 100 electrodes.

A ferrofluid deformable mirror

Ferrofluid concept mirrors are liquid deformable mirrors made with a suspension of small (about 10 nm in diameter) ferromagnetic nanoparticles dispersed in a liquid carrier. In the presence of an external magnetic field, the ferromagnetic particles align with the field, the liquid becomes magnetized and its surface acquires a shape governed by the equilibrium between the magnetic, gravitational and surface tension forces. Using proper magnetic field geometries, any desired shape can be produced at the surface of the ferrofluid. This new concept offers a potential alternative for low-cost, high stroke and large number of actuators deformable mirrors.[1][2][3]

See also

References

  1. ^ P. Laird, R. Bergamasco, V. Berube, E.F. Borra, A. Ritcey, M. Rioux, N. Robitaille, S. Thibault, L. Vieira da Silva Jr, H. Yockell-Lelievre (August 2002). Ferrofluid Based Deformable Mirrors - a New Approach to Adaptive Optics Using Liquid Mirrors. Proceedings of SPIE Astronomical Telescopes and Instrumentation meeting. arXiv:astro-ph/0212189. doi:10.1117/12.459065. 
  2. ^ P. Laird, N. Caron, M. Rioux, E. F. Borra, and A. Ritcey (2006). "Ferrofluidic adaptive mirrors". Applied Optics 45 (15): 3495–3500. doi:10.1364/AO.45.003495. http://www.opticsinfobase.org/abstract.cfm?&id=89847. 
  3. ^ Denis Brousseau, Ermanno F. Borra, and Simon Thibault (2007). "Wavefront correction with a 37-actuator ferrofluid deformable mirror". Optics Express 15 (26): 18190–18199. doi:10.1364/OE.15.018190. http://www.opticsinfobase.org/abstract.cfm?id=148579. 

Wikimedia Foundation. 2010.

Игры ⚽ Поможем сделать НИР

Look at other dictionaries:

  • Mirror — looking glass redirects here. For other uses, see Looking Glass (disambiguation). This article is about wave reflectors (mainly, specular reflection of visible light). For other uses, see Mirror (disambiguation). A mirror, reflecting a vase A… …   Wikipedia

  • Monolithic Mirror Telescope — Observatoire MMT L observatoire MMT (en anglais MMT Observatory ou MMTO) est un observatoire astronomique situé sur le site de l observatoire Fred Lawrence Whipple (code observatoire UAI 696). L observatoire Whipple est situé sur le Mount Hopkins …   Wikipédia en Français

  • Multiple Mirror Telescope — Observatoire MMT L observatoire MMT (en anglais MMT Observatory ou MMTO) est un observatoire astronomique situé sur le site de l observatoire Fred Lawrence Whipple (code observatoire UAI 696). L observatoire Whipple est situé sur le Mount Hopkins …   Wikipédia en Français

  • Adaptive optics — (AO) is a technology used to improve the performance of optical systems by reducing the effects of rapidly changing optical distortion. It is used in astronomical telescopes and laser communication systems to remove the effects of atmospheric… …   Wikipedia

  • Tilt (optics) — In optics, the term tilt is a deviation in the direction a beam of light propagates. Tilt quantizes the average slope in both the X and Y directions of a wavefront or phase profile across the pupil of an optical system. In conjunction with Piston …   Wikipedia

  • Scanning laser ophthalmoscopy — Retinal image of a left eye via Optos Optomap. Scanning laser ophthalmoscopy (SLO) is a method of examination of the eye. It uses the technique of confocal laser scanning microscopy for diagnostic imaging of retina or cornea of the human eye. As… …   Wikipedia

  • Compagnie industrielle des lasers — Création 1966 …   Wikipédia en Français

  • History of the telescope — The earliest known working telescopes appeared in 1608 and are credited to Hans Lippershey and Zacharias Janssen, spectacle makers in Middelburg, and Jacob Metius of Alkmaar. The design of these early refracting telescopes consisted of a convex… …   Wikipedia

  • Digital micromirror device — DLP chip A digital micromirror device, or DMD, is an optical semiconductor that is the core of DLP projection technology[1], and was invented by Dr. Larry Hornbeck and Dr. William E. Ed Nelson of Texas Instruments (TI) in 1987. The DMD project… …   Wikipedia

  • Dispositivo digital de microespejos — Saltar a navegación, búsqueda Un Dispositivo digital de microespejos o DMD (siglas de Digital Micromirror Device), es un tipo de semiconductor óptico. Es la base de la tecnología de proyección DLP y fue inventado en 1987 por Larry Hornbeck y… …   Wikipedia Español

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”