Classical interference microscopy

Classical interference microscopy

Classical interference microscopy (also referred to as quantitative interference microscopy) uses two separate light beams with much greater lateral separation than that used in phase contrast microscopy or in differential interference microscopy (DIC).

In variants of the interference microscope where object and reference beam pass through the same objective, two images are produced of every object (one being the "ghost image"). The two images are separated either laterally within the visual field or at different focal planes, as determined by the optical principles employed. These two images can be a nuisance when they overlap, since they can severely affect the accuracy of mass thickness measurements. Rotation of the preparation may thus be necessary, as in the case of DIC.

One of the first usable interference microscopes was designed by Dyson[1] and manufactured by Cooke Troughton & Simms (later Vickers Instruments), York England. This ingenious optical system achieved interference imaging without requiring polarizing elements in the beam path.

A later popular design involving polarizing elements was designed by Smith[2][3] and marketed first by C. Baker, London, and subsequently by the American Optical Company in USA.

The double-image problem commonly encountered with all the above-mentioned designs was completely avoided in the Mach-Zehnder interferometer design implemented by Horn, a most expensive instrument, not employing polarized light, but requiring precisely-matched duplicated objectives and condensers. With this design (marketed by E. Leitz) 60 mm beam separation was achieved in microscopy but here the new difficulty has arisen of balancing optical thicknesses of two separate microscope slide preparations (sample and dummy) and maintaining this critical balance during longer observations (e.g. time-lapse studies of living cells maintained at 37°C), otherwise a gradual change in background interference colour occurs over time.

The main advantage offered by interference microscopy measurements is the possibility of measuring the projected dry mass of living cells, which was first effectively exploited by Andrew Huxley in studies of striated muscle cell structure and function, leading to the sliding filament model of muscle contraction. [4]

Interference microscopy became relatively popular in the 1940-1970 decades but fell into disuse because of the complexity of the instrument and difficulties in both its use and in the interpretation of image data. In recent years, however, the classical interference microscope (in particular the Mach-Zehnder instrument) has been "rediscovered" by biologists because its main original disadvantage (difficult interpretation of translated interference bands or complex coloured images) can now be easily surmounted by means of digital camera image recording, followed by the application of computer algorithms which rapidly deliver the processed data as false-colour images of projected dry mass. Examples of computer-assisted developments of the technique are found in the application of "DRIMAPS" from the laboratory of Graham Dunn [5] and other recent developments of the methodology are described by Mahlmann et al [6] [7].

References

  1. ^ Dyson J. (1950). "An Interferometer Microscope.". Proc. Roy. Soc. A. 204 (1077): 170–187.. doi:10.1098/rspa.1950.0167. 
  2. ^ Smith F. H. (1954). "Two Half-Shade Devices for Optical Polarizing Instruments.". Nature 173 (4399): 362–363.. doi:10.1038/173362b0. 
  3. ^ Smith F. H. (1955). "Microscopic interferometry". Research 8: 385–395.. 
  4. ^ Huxley, A. F. & Niedergerke, R. (1954). "Structural changes in muscle during contraction; interference microscopy of living muscle fibres.". Nature 173 (4412): 971–973. doi:10.1038/173971a0. PMID 13165697. 
  5. ^ Zicha, D. Genot, E. Dunn, G. A. & Kramer, I. M. (1999). "TGFbeta1 induces a cell-cycle-dependent increase in motility of epithelial cells". Journal of Cell Science 112: 447–454. PMID 9914157. 
  6. ^ Mahlmann, D. M. Jahnke, J. & Loosen, P. (2008). "Rapid determination of the dry weight of single, living cyanobacterial cells using the Mach-Zehnder double-beam interference microscope". Eur. J. Phycol. 43: 355–364. doi:10.1080/09670260802168625. 
  7. ^ Kaul, R. A. Mahlmann, D. M. & Loosen, P. (2010). "Mach-Zehnder interference microscopy optically records electrically stimulated cellular activity in unstained nerve cells". J. Microscopy 240: 60–74. doi:10.1111/j.1365-2818.2010.03385.x. PMID 21050214. 

Instrumentation History & Makers' Names

  • Smith system (C. Baker, London, England)
  • Dyson (Cooke Troughton & Simms, York, England)
  • Jamin-Lebedeff (E. Leitz, Wetzlar, & Zeiss, Germany)
  • Mach-Zehnder (E. Leitz, Wetzlar, Germany)



Wikimedia Foundation. 2010.

Игры ⚽ Нужен реферат?

Look at other dictionaries:

  • Interference microscopy — involving measurements of differences in the path between two beams of light that have been split.[1] Types include: Classical interference microscopy Differential interference contrast microscopy Fluorescence interference contrast microscopy See …   Wikipedia

  • Microscopy — is the technical field of using microscopes to view samples and objects that cannot be seen with the unaided eye (objects that are not within the resolution range of the normal eye). There are three well known branches of microscopy, optical,… …   Wikipedia

  • Interference microscope — might refer to: * Classical interference microscopy (interference between well separated beams) * Differential interference contrast microscopy (also called Nomarski Interference Contrast or Nomarski microscopy) * Fluorescence interference… …   Wikipedia

  • Differential interference contrast microscopy — Micrasterias furcata imaged in transmitted DIC microscopy. Differential interference contrast microscopy (DIC), also known as Nomarski Interference Contrast (NIC) or Nomarski microscopy, is an optical microscopy illumination technique used to… …   Wikipedia

  • Digital holographic microscopy — Contents 1 Working principle 2 Advantages 3 Applications 4 …   Wikipedia

  • List of types of interferometers — Field and linear interferometers = *Astronomical interferometer / Michelson stellar interferometer *Classical interference microscopy *Cyclic interferometer *Diffraction grating interferometer (white light) *Double slit interferometer *Fabry… …   Wikipedia

  • Mach-Zehnder interferometer — The Mach Zehnder interferometer (named after physicists Ludwig Mach (son of Ernst Mach) and Ludwig Zehnder) is a device used to determine the phase shift caused by a small sample which is placed in the path of one of two collimated beams (thus… …   Wikipedia

  • optics — /op tiks/, n. (used with a sing. v.) the branch of physical science that deals with the properties and phenomena of both visible and invisible light and with vision. [1605 15; < ML optica < Gk optiká, n. use of neut. pl. of OPTIKÓS; see OPTIC,… …   Universalium

  • microscope — /muy kreuh skohp /, n. 1. an optical instrument having a magnifying lens or a combination of lenses for inspecting objects too small to be seen or too small to be seen distinctly and in detail by the unaided eye. 2. (cap.) Astron. the… …   Universalium

  • Neurofibrillary tangle — Microscopy image of a neurofibrillary tangle, conformed by hyperphosphorylated tau protein Neurofibrillary Tangles (NFTs) are aggregates of hyperphosphorylated tau protein that are most commonly known as a primary marker of Alzheimer s Disease.… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”