Mach-Zehnder interferometer

Mach-Zehnder interferometer

The Mach-Zehnder interferometer (named after physicists Ludwig Mach (son of Ernst Mach) and Ludwig Zehnder) is a device used to determine the phase shift caused by a small sample which is placed in the path of one of two collimated beams (thus having plane wavefronts) from a coherent light source.

In contrast to the Michelson interferometer, there are two output ports.

How it works

et-up

A collimated beam is split by a half-silvered mirror. The two resulting beams (the "sample beam" and the "reference beam") are each reflected by a mirror. The two beams then pass a second half-silvered mirror and enter two detectors ("detector 1" and "detector 2"). It is important that the fully-silvered and half-silvered surfaces of all mirrors, except the last, face the inbound beam, and that the half-silvered surface of the last mirror faces the outbound beam exiting in the same orientation as the original collimated beam. That is, if the original beam is horizontal, the half-silvered surface of the last mirror should face the horizontally outbound beam.

Properties

It is important to consider that the medium of a mirror is what lies behind it; that is, if a glass substrate has its half-silvered or fully-silvered surface facing the inbound beam, then the inbound beam travels through air and is reflected off the surface of a glass medium – if, however, the half-silvered or fully-silvered surface faces away from the inbound beam, then the inbound beam travels through glass and is reflecting off the surface of an air medium.

The following rules apply to phase shifts due to material:

* Reflection or refraction at the surface of a medium with a lower refractive index causes no phase shift.
* Reflection at the surface of a medium with a higher refractive index causes a phase shift of half of a wavelength.
* The speed of light is slower in media with an index of refraction greater than that of a vacuum, which is 1. Specifically, its speed is: v = frac{c}{n}, where "c" is the speed of light in vacuum and "n" is the index of refraction. This causes a phase shift proportional to "n" * "length traveled".

Given the above rules, mirrors, including half-silvered mirrors, have the following properties:

* A ½ wavelength phase shift occurs upon reflection from the front of a mirror, since the medium behind the mirror (glass) has a higher refractive index than the medium the light is traveling in (air).
* If "k" is the constant phase shift incurred by passing through a glass plate on which a mirror resides, a total of 2"k" phase shift occurs when reflecting off the rear of a mirror. This is because light traveling toward the rear of a mirror will enter the glass plate, incurring "k" phase shift, and then reflect off the mirror with no additional phase shift since only air is now behind the mirror, and travel again back through the glass plate incurring an additional "k" phase shift.

Observing the effect of a sample

Without a sample, there is no phase difference in the two beams in detector 1 (B), yielding constructive interference. Both beams will have undergone a phase shift of wavelength + "k" due to two front-side reflections and one transmission through a glass plate. At detector 2 (A), there is a phase difference of ½ wavelength, yielding complete destructive interference. The reference beam into detector 2 (A) has undergone a phase shift of ½ wavelength + 2"k" due to one front-side reflection and two transmissions. The sample beam into detector 2 (A) has undergone a wavelength + 2"k" phase shift due to two front-side reflections and one rear-side reflection. Therefore, when there is no sample, only detector 1 (B) receives light.

If a sample is placed in the path of the sample beam, the intensities of the beams entering the two detectors will change, allowing the calculation of the phase shift caused by the sample.


ee also

* Interferometer
* Elitzur-Vaidman bomb-testing problem
* Time-bin encoding
* Jamin interferometer
* Mach-Zehnder modulator
* Classical interference microscopy

Flow visualisation techniques

* Schlieren
* Schlieren photography
* Shadowgraph

References

* Ludwig Zehnder, Z. Instrumentenkunde 11 (1891) 275.
* Ludwig Mach, Z. Instrumentenkunde 12 (1892) 89.
* p. 170. (First published in German in 1926.)

External links

* [http://www.upscale.utoronto.ca/GeneralInterest/Harrison/MachZehnder/MachZehnder.html Mach-Zehnder Interferometer]


Wikimedia Foundation. 2010.

Игры ⚽ Поможем написать курсовую

Look at other dictionaries:

  • Mach-Zehnder-Interferometer — Skizze eines Mach Zehnder Interferometers Das Mach Zehnder Interferometer ist eine Weiterentwicklung des Jamin Interferometers. Es wurde 1891/1892 unabhängig voneinander vom Österreicher Ludwig Mach (Sohn von Ernst Mach) und seinem Schweizer… …   Deutsch Wikipedia

  • Mach-Zehnder-Interferometer — Mạch Zehnder Interferometer   [nach E. Mach und dem schweizerischen Physiker L. A. Zehnder, * 1854, ✝ 1949], ein Zweistrahlinterferometer (Interferometer), bei dem eine große räumliche Trennung der beiden Teilstrahlenbündel möglich ist. Es… …   Universal-Lexikon

  • Mach-Zehnder-Modulator — Ein Mach Zehnder Modulator ist ein optisches Bauteil um Licht in seiner Intensität zu modulieren. Schematischer Aufbau eines Mach Zehnder Modulators. BS: Strahlteiler, M: Spiegel …   Deutsch Wikipedia

  • Interferometre de Mach-Zehnder — Interféromètre de Mach Zehnder Principe de l interféromètre de Mach Zehnder L interféromètre de Mach Zehnder est un interféromètre optique créé par Ludwig Mach, fils d Ernst Mach, et Ludwig Zehnder. Il est constitué de deux miroirs et de deux… …   Wikipédia en Français

  • Interféromètre De Mach-Zehnder — Principe de l interféromètre de Mach Zehnder L interféromètre de Mach Zehnder est un interféromètre optique créé par Ludwig Mach, fils d Ernst Mach, et Ludwig Zehnder. Il est constitué de deux miroirs et de deux miroirs semi réfléchissants. Comm …   Wikipédia en Français

  • Interféromètre de mach-zehnder — Principe de l interféromètre de Mach Zehnder L interféromètre de Mach Zehnder est un interféromètre optique créé par Ludwig Mach, fils d Ernst Mach, et Ludwig Zehnder. Il est constitué de deux miroirs et de deux miroirs semi réfléchissants. Comm …   Wikipédia en Français

  • Interféromètre de Mach-Zehnder — Principe de l interféromètre de Mach Zehnder L interféromètre de Mach Zehnder est un interféromètre optique créé par Ludwig Mach, fils d Ernst Mach, et Ludwig Zehnder. Il est constitué de deux miroirs et de deux miroirs semi réfléchissants. Comme …   Wikipédia en Français

  • Mach — ist der Familienname folgender Personen: Alexander Mach (1902–1980), slowakischer Journalist und Politiker, Hauptorganisator der Deportation slowakischer Juden Edmund Mach (Chemiker) (1846–1901), österreichischer Agrarchemiker und Önologe Edmund… …   Deutsch Wikipedia

  • Zehnder (Begriffsklärung) — Zehnder ist ein deutsches Unternehmen im Bereich Antennen und Satellitenempfangstechnik, siehe Heinrich Zehnder GmbH der Name eines Schweizer Industrieunternehmens, siehe Zehnder sowie der Name von folgenden Personen: Bruno P. Zehnder (Bruno… …   Deutsch Wikipedia

  • Interferometer — Ein Interferometer ist ein technisches Gerät, das der Interferometrie dient. Es wird für die Feststellung von Interferenzen (Überlagerungen von Wellen, hier Lichtwellen) für Präzisionsmessungen genutzt. Einsatzfelder sind die Längenmessung, die… …   Deutsch Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”