Oil immersion

Oil immersion
Principle of immersion microscopy. Path of rays with immersion medium (yellow) (left half) and without (right half). Rays (black) coming from the object (red) at a certain angle and going through the coverslip (orange, as the slide at the bottom) can enter the objective (dark blue) only when immersion is used. Otherwise, the refraction at the coverslip - air interface causes the ray to miss the objective and its information is lost.
Two Leica oil immersion objective lenses. Oil immersion objective lenses look superficially identical to non-oil immersion lenses.

In light microscopy, oil immersion is a technique used to increase the resolution of a microscope. This is achieved by immersing both the objective lens and the specimen in a transparent oil of high refractive index, thereby increasing the numerical aperture of the objective lens.

Immersion oils are transparent oils that have specific optical and viscosity characteristics necessary for use in microscopy. Typical oils used have an index of refraction around 1.515[1]. An oil immersion objective is an objective lens specially designed to be used in this way. Many condensers also give optimal resolution when the condenser lens is immersed in oil.

Contents

Theoretical background

The resolution of a microscope is defined as the minimum separation needed between two objects under examination in order for the microscope to discern them as separate objects. This minimum distance is labelled δ. If two objects are separated by a distance shorter than δ, they will appear as a single object in the microscope.

A measure of the resolving power of a lens is given by its numerical aperture, NA:

\delta=\frac{\lambda}{\mathrm{NA}}

where λ is the wavelength of light. From this it is clear that a good resolution (small δ) is connected with a high numerical aperture.

The numerical aperture of a lens is defined as

\mathrm{NA} = n \sin \alpha_0\;

where α0 is the angle spanned by the objective lens seen from the sample, and n is the refractive index of the medium between the lens and specimen (≈1 for air).

State of the art objectives can have a numerical aperture of up to 0.95. Because sin α0 is always less than or equal to unity, the numerical aperture can never be greater than unity for an objective lens in air. If the space between the objective lens and the specimen is filled with oil however, the numerical aperture can obtain values greater than unity. This is because oil has a refractive index greater than 1.

Oil immersion objectives

From the above it is understood that oil between the specimen and the objective lens improves the resolving power by a factor 1/n. Objectives specifically designed for this purpose are known as oil immersion objectives.

Oil immersion objectives are used only at very large magnifications that require high resolving power. Objectives with high power magnification have short focal lengths, facilitating the use of oil. The oil is applied to the specimen (conventional microscope), and the stage is raised, immersing the objective in oil. (In inverted microscopes the oil is applied to the objective).

The refractive indices of the oil and of the glass in the first lens element are nearly the same, which means that the refraction of light will be small upon entering the lens (the oil and glass are optically very similar). The correct immersion oil for an objective lens has to be used to ensure that the refractive indices are correctly matched. Use of an oil immersion lens with the incorrect immersion oil, or without immersion oil altogether, will suffer from spherical aberration. The strength of this effect depends on the size of the refractive index mismatch.

Oil immersion can generally only be used on rigidly mounted specimens otherwise the surface tension of the oil can move the coverslip and so move the sample underneath. This also happen on inverted microscopes because the coverslip is below the slide.

Immersion oil

Before the development of synthetic immersion oils in the 1940s Cedar tree oil was widely used. Cedar oil has an index of refraction of approximately 1.516. The numerical aperture of cedar tree oil objectives is generally around 1.3. Cedar oil has a number of disadvantages however: it absorbs blue and ultraviolet light, yellows with age, has sufficient acidity to potentially damage objectives with repeated use (by attacking the cement used to join lenses), and diluting it with solvent changes its viscosity (and refraction index and dispersion). Cedar oil must be removed from the objective immediately after use before it can harden, since removing hardened cedar oil can damage the lens. In modern microscopy synthetic immersion oils are more commonly used, as they eliminate most of these problems.[2] NA values of 1.6 can be achieved with different oils. Unlike natural oils synthetic ones do not harden on the lens and can typically be left on the objective for months at a time, though dust accumulation can be a problem. Xylene is often used to remove oil from the objective when desired.

See also

References

  1. ^ "Microscope Objectives: Immersion Media" by Mortimer Abramowitz and Michael W. Davidson, Olympus Microscopy Resource Center (website), 2002.
  2. ^ Cargille, John (1964 (revised 1985)), "Immersion Oil and the Microscope", New York Microscopical Society Yearbook, http://www.cargille.com/immersionoilmicroscope.shtml 
  • Practical Microscopy by L.C. Martin and B.K. Johnson , Glasgow (1966).
  • Light Microscopy by J.K. Solberg, Tapir Trykk (2000).

External links


Wikimedia Foundation. 2010.

Игры ⚽ Нужен реферат?

Look at other dictionaries:

  • oil immersion — noun A technique, used to extend the resolving power of a light microscope, in which a thin film of oil is placed between a special oil immersion objective lens and the specimen • • • Main Entry: ↑oil …   Useful english dictionary

  • oil-immersion lens — n an objective lens designed to work with a drop of liquid (as oil or water) between the lens and cover glass called also immersion lens, immersion objective, oil immersion objective …   Medical dictionary

  • oil-immersion objective — oil immersion objective. См. иммерсионный объектив. (Источник: «Англо русский толковый словарь генетических терминов». Арефьев В.А., Лисовенко Л.А., Москва: Изд во ВНИРО, 1995 г.) …   Молекулярная биология и генетика. Толковый словарь.

  • oil immersion — the covering of the microscopical objective and the object with oil …   Medical dictionary

  • oil-immersion objective — /oyl i merr zheuhn, sheuhn/, Optics. See immersion objective. [1880 85] * * * …   Universalium

  • oil-immersion lens — noun : immersion lens …   Useful english dictionary

  • oil-immersion objective — /oyl i merr zheuhn, sheuhn/, Optics. See immersion objective. [1880 85] …   Useful english dictionary

  • immersion objective — n OIL IMMERSION LENS * * * a microscope objective designed to have its tip and the cover glass over the specimen connected by a liquid instead of by air. The liquid may be water (water immersion) or a specially prepared oil (oil immersion) …   Medical dictionary

  • immersion oil — n oil that is used with an oil immersion lens …   Medical dictionary

  • immersion lens — n OIL IMMERSION LENS * * * see under objective …   Medical dictionary

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”