Spin polarized scanning tunneling microscopy

Spin polarized scanning tunneling microscopy

Spin polarized scanning tunneling microscopy (SP-STM) is a specialized application of scanning tunneling microscopy (STM) that can provide detailed information of magentic phenomena on the single atom scale additional to the atomic topology gained with STM. SP-STM was developed by Roland Wiesendanger at the University of Hamburg (Germany) and opened a novel approach to static and dynamic magnetic processes as precise investigations of domain walls in ferromgnetic and antiferromagnetic systems, as well as thermal and current induced switching of nanomagnetic particles.

How it works

An extremely sharp tip coated with a thin layer of magnetic material is moved systematically over a sample. A voltage is applied between the tip and the sample allowing electrons to tunnel between the two, resulting in a current. In the absence of magnetic phenomena, the strength of this current is indicative for local electronic properties.

If the tip is magnetized, however, electrons with spins matching the tip's magnetization will have a higher chance of tunneling. This is essentially the effect of tunnel magnetoresistance and the tip/surface essentially acts as a spin valve.

Since a scan using only a magnetized tip cannot distinguish between current changes due to magnetization or space separation, multi-domain structures and/or topological information from another source (frequently conventional STM) must be utilized. Then, magnetic imaging down to the atomic scale, i.e. for example in antiferromagnetic system, can be achieved.

Nowadays, antiferromagnetic tips are preferred since ferromagnetic tips induce magnetization reversal in the systems to be studied due to stray fields. In STM tunneling electrons come from the very same atom most close to the surface. Therefore, with the magnetization of this atom well defined, the tunneling current remains polarized for antiferromagnetic tips but without stray field.

Alternate Method

Another way to obtain the magnetization distribution is to have the tip provide a strong stream of spin polarized electrons. One method to achieve this is to shine polarization laser light onto a GaAs tip, which produces spin polarized electrons due to spin-orbit coupling. The tip is then scanned along the sample much like conventional STM. One limitation of this method is that the most effective source of spin polarized electrons is obtained by having the incident laser light shine directly opposite of the tip, i.e. through the sample itself. This restricts the method to measuring thin samples.

See also

* Scanning tunneling microscopy
* Microscopy
* Scanning probe microscopy
* spin valve
* tunnel magnetoresistance

External links

[http://nanowiz.tripod.com/spstm/spstm.htm] A brief overview of STM written for a physics class [http://www.iop.org/EJ/abstract/0034-4885/66/4/203] A more lengthy discussion [http://www.nanoscience.de/group_r/] recent activities of the original group


Wikimedia Foundation. 2010.

Игры ⚽ Поможем написать курсовую

Look at other dictionaries:

  • Scanning tunneling microscope — Image of reconstruction on a clean Gold(100) surface …   Wikipedia

  • Scanning probe microscopy — Part of a series of articles on Nanotechnology …   Wikipedia

  • Scanning voltage microscopy — (SVM) sometimes also called nanopotentiometry is a scientific experimental technique based on atomic force microscopy. A conductive probe, usually only a few nanometers wide at the tip, is placed in full contact with an operational electronic or… …   Wikipedia

  • Conductive atomic force microscopy — (C AFM) is a variation of atomic force microscopy (AFM) and scanning tunneling microscopy (STM), which uses electrical current to construct the surface profile of the studied sample. The current is flowing through the metal coated tip of the… …   Wikipedia

  • Magnetic resonance force microscopy — (MRFM) is an imaging technique that acquires magnetic resonance images (MRI) at nanometer scales, and possibly at atomic scales in the future. MRFM is potentially able to observe protein structures which cannot be seen using X ray crystallography …   Wikipedia

  • Near-field scanning optical microscope — Near field scanning optical microscopy (NSOM/SNOM) is a microscopic technique for nanostructure investigation that breaks the far field resolution limit by exploiting the properties of evanescent waves. This is done by placing the detector very… …   Wikipedia

  • Feature-oriented scanning — (FOS)[1][2][3] is a method intended for high precision measurement of nanotopography as well as other surface properties and characteristics on a scanning probe microscope (SPM) using features (objects) of the surface as reference points of the… …   Wikipedia

  • Counter-scanning — (CS)[1] is a method for measuring surface topography with a scanning probe microscope enabling correction of raster distortions resulted from drift of the microscope probe relative to the surface being measured. Two surface scans, viz. direct… …   Wikipedia

  • Low-energy electron microscopy — Low energy electron microscopy, or LEEM, is a technique used by surface scientists to study surface structure at mesoscopic scale on conducting and semiconducting materials. It is based on imaging the electrons elastically scattered from the… …   Wikipedia

  • Microscope — This article is about microscopes in general. For light microscopes, see optical microscope. Microscope Us …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”