- Frequency domain sensor
Frequency domain (FD) sensor is an instrument developed for measuring
soil moisture content. The instrument has an oscillating circuit, the sensing part of the sensor is embedded in the soil, and the operating frequency will depend on the value of soil'sdielectric constant .There are two types of sensors:
* "Capacitance probe", or fringe capacitance sensor. Capacitance probes use capacitance to measure the dielectric permittivity of the soil. The volume of water in the total volume of soil most heavily influences the dielectric permittivity of the soil because the dielectric of water (80) is much greater than the other constituents of the soil (mineral soil: 4, organic matter: 4, air: 1). Thus, when the amount of water changes in the soil, the probe will measure a change in capacitance (from the change in dielectric permittivity) that can be directly correlated with a change in water content. Circuitry inside some commercial probes change the capacitance measurement into a proportional millivolt output. Other configuration are like theneutron probe where an access tube made ofPVC is installed in the soil. The probe consists of sensing head at fixed depth. The sensing head consists of anoscillator circuit, the frequency is determined by an annular electrode, fringe-effectcapacitor , and thedielectric constant of the soil.* "Electrical impedance sensor", which consists of soil probes and using electrical impedance measurement. The most common configuration is based on the
standing wave principle (Gaskin & Miller, 1996). The device comprises a 100 MHz sinusoidaloscillator , a fixed impedancecoaxial transmission line , and probe wires which is buried in the soil. The oscillator signal is propagated along the transmission line into the soil probe, and if the probe's impedance differs from that of the transmission line, a proportion of the incident signal is reflected back along the line towards the signal source.Compared with
time domain reflectometer (TDR), FD sensors are cheaper to built and have a faster response time. However because of the complex electrical field around the probe, the sensor needs to be calibrated for different soil types. Some commercial sensors have been able to remove the soil type sensitivity by using a high frequency.References
* Gaskin G.J., Miller J.D. 1996. Measurement of soil water content using a simplified impedance measuring technique. Journal of Agricultural Engineering Research 63, 153-160.
*Campbell C.S., Campbell G.S., Cobos D.R.2004. Response of Low Cost Dielectric Moisture Sensor to Temperature Variation. Eos Trans. AGU, 85(17), Jt. Assem. Suppl. Abstract NS44A-05.