- Real-time polymerase chain reaction
In
molecular biology , real-time polymerase chain reaction, also called quantitative real time polymerase chain reaction (qPCR) or kinetic polymerase chain reaction, is alaboratory technique based on thepolymerase chain reaction , which is used to amplify and simultaneously quantify a targetedDNA molecule. It enables both detection and quantification (as absolute number of copies or relative amount when normalized to DNA input or additional normalizing genes) of a specific sequence in a DNA sample.The procedure follows the general principle of polymerase chain reaction; its key feature is that the amplified DNA is quantified as it accumulates in the reaction in "real time" after each amplification cycle. Two common methods of quantification are the use of
fluorescent dye s that intercalate with double-stranded DNA, and modified DNAoligonucleotide probes that fluoresce when hybridized with a complementary DNA.Frequently, real-time polymerase chain reaction is combined with
reverse transcription polymerase chain reaction to quantify low abundancemessenger RNA (mRNA), enabling a researcher to quantify relativegene expression at a particular time, or in a particular cell or tissue type.Although real-time quantitative polymerase chain reaction is often marketed as RT-PCR, it should not be confused with
reverse transcription polymerase chain reaction , also known as RT-PCR.Background
Cells in all organisms regulate
gene expression and turnover of gene transcripts (messenger RNA, abbreviated tomRNA ), and the number of copies of an mRNA transcript of a gene in a cell or tissue is determined by the rates of its expression and degradation.Northern blotting is often used to estimate the expression level of a gene by visualizing the abundance of its mRNA transcript in a sample. In this method, purified RNA is separated by
agarose gel electrophoresis , transferred to a solid matrix (such as a nylon membrane), and probed with a specific DNA probe that is complementary to the gene of interest. Although this technique is still used to assess gene expression, it requires relatively large amounts of RNA and provides only qualitative or semiquantitative information of mRNA levels.In order to robustly detect and quantify gene expression from small amounts of RNA, amplification of the gene transcript is necessary. The
polymerase chain reaction is a common method for amplifying DNA; for mRNA-based PCR the RNA sample is first reverse transcribed to cDNA withreverse transcriptase .Development of PCR technologies based on reverse transcription and "
fluorophore s" permits measurement of DNA amplification during PCR in real time, i.e., the amplified product is measured at each PCR cycle. The data thus generated can be analysed by computer software to calculate "relative gene expression" in several samples, or "mRNA copy number". Real-time PCR can also be applied to the detection and quantification of DNA in samples to determine the presence and abundance of a particular DNA sequence in these samples.Real-time PCR using double-stranded DNA dyes
A DNA-binding dye binds to all double-stranded (ds)
DNA in a PCR reaction, causing fluorescence of the dye. An increase in DNA product during PCR therefore leads to an increase in fluorescence intensity and is measured at each cycle, thus allowing DNA concentrations to be quantified. However, dsDNA dyes such as SYBR Green will bind to all dsDNA PCR products, including nonspecific PCR products (such as "primer dimers"). This can potentially interfere with or prevent accurate quantification of the intended target sequence.#The reaction is prepared as usual, with the addition of fluorescent dsDNA dye.
#The reaction is run in athermocycler , and after each cycle, the levels of fluorescence are measured with a detector; the dye only fluoresces when bound to the dsDNA (i.e., the PCR product). With reference to a standard dilution, the dsDNA concentration in the PCR can be determined.Like other real-time PCR methods, the values obtained do not have absolute units associated with it (i.e. mRNA copies/cell). As described above, a comparison of a measured DNA/RNA sample to a standard dilution will only give a fraction or ratio of the sample relative to the standard, allowing only relative comparisons between different tissues or experimental conditions. To ensure accuracy in the quantification, it is usually necessary to
normalize expression of a target gene to a stably expressed gene (see below). This can correct possible differences in RNA quantity or quality across experimental samples.Fluorescent reporter probe method
Using fluorescent reporter probes is the most accurate and most reliable of the methods, but also the most expensive. It uses a sequence-specific RNA or DNA-based probe to quantify only the DNA containing the probe sequence; therefore, use of the reporter probe significantly increases specificity, and allows quantification even in the presence of some non-specific DNA amplification. This potentially allows for multiplexing - assaying for several genes in the same reaction by using specific probes with different-coloured labels, provided that all genes are amplified with similar efficiency.
It is commonly carried out with an RNA-based probe with a fluorescent reporter at one end and a quencher of fluorescence at the opposite end of the probe. The close proximity of the reporter to the quencher prevents detection of its fluorescence; breakdown of the probe by the 5' to 3'
exonuclease activity of thetaq polymerase breaks the reporter-quencher proximity and thus allows unquenched emission of fluorescence, which can be detected. An increase in the product targeted by the reporter probe at each PCR cycle therefore causes a proportional increase in fluorescence due to the breakdown of the probe and release of the reporter.#The PCR reaction is prepared as usual (see
PCR ), and the reporter probe is added.
#As the reaction commences, during the annealing stage of the PCR both probe and primers anneal to the DNA target.
#Polymerisation of a new DNA strand is initiated from the primers, and once the polymerase reaches the probe, its 5'-3-exonuclease degrades the probe, physically separating the fluorescent reporter from the quencher, resulting in an increase in fluorescence.
#Fluorescence is detected and measured in the real-time PCR thermocycler, and its geometric increase corresponding to exponential increase of the product is used to determine the threshold cycle (CT) in each reaction.Quantitation
Quantitating gene expression by traditional methods presents several problems. Firstly, detection of
mRNA on aNorthern blot or PCR products on a gel orSouthern blot is time-consuming and does not allow precise quantitation. Also, over the 20-40 cycles of a typical PCR reaction, the amount of product reaches a plateau determined more by the amount of primers in the reaction mix than by the input template/sample.Relative concentrations of DNA present during the exponential phase of the reaction are determined by plotting fluorescence against cycle number on a
logarithmic scale (so an exponentially increasing quantity will give a straight line). A threshold for detection of fluorescence above background is determined. The cycle at which the fluorescence from a sample crosses the threshold is called the cycle threshold, Ct. Since the quantity of DNA doubles every cycle during the exponential phase, relative amounts of DNA can be calculated, e.g. a sample whose Ct is 3 cycles earlier than another's has 23 = 8 times more template.Amounts of RNA or DNA are then determined by comparing the results to a
standard curve produced by RT-PCR of serial dilutions (e.g. undiluted, 1:4, 1:16, 1:64) of a known amount of RNA or DNA. As mentioned above, to accurately quantify gene expression, the measured amount of RNA from the gene of interest is divided by the amount of RNA from a housekeeping gene measured in the same sample to normalize for possible variation in the amount and quality of RNA between different samples. This normalization permits accurate comparison of expression of the gene of interest between different samples, provided that the expression of the reference (housekeeping) gene used in the normalization is very similar across all the samples. Choosing a reference gene fulfilling this criterion is therefore of high importance, and often challenging, because only very few genes show equal levels of expression across a range of different conditions or tissues. cite journal|author=Nolan T, Hands RE, Bustin SA|year= 2006|title=Quantification of mRNA using real-time RT-PCR.|journal=Nat. Protoc. |volume=1|pages=1559–1582|pmid=17406449|doi=10.1038/nprot.2006.236]Applications of real-time polymerase chain reaction
There are numerous applications for real-time polymerase chain reaction in the
laboratory . It is commonly used for both diagnostic and research applications.Diagnostically real-time PCR is applied to rapidly detect the presence of genes involved in
infectious diseases ,cancer and genetic abnormalities. The introduction of real-time PCR assays to the clinical microbiology laboratory has led to significant improvements in the diagnosis of infectious disease.cite book |author= Sails AD|year=2009|chapter=Applications in Clinical Microbiology|title=Real-Time PCR: Current Technology and Applications|publisher=Caister Academic Press|id= ISBN 978-1-904455-39-4] In the research setting, real-time PCR is mainly used to provide highly sensitive quantitative measurements of gene transcription.The technology may be used in determining how the genetic expression of a particular gene changes over time, such as in the response of tissue and cell cultures to an administration of a pharmacological agent, progression of cell differentiation, or in response to changes in environmental conditions.
Also, the technique is used in
Environmental microbiology , for example to quantify resistance genes in water samples.References
Further reading
* Higuchi, R., Dollinger, G., Walsh, P. S., and Griffith, R. (1992). "Simultaneous amplification and detection of specific DNA sequences." "Biotechnology" 10:413–417.
* Higuchi, R., Fockler, C., Dollinger, G., and Watson, R. (1993). "Kinetic PCR: Real time monitoring of DNA amplification reactions." "Biotechnology" 11:1026–1030.
* Mackay, I. M. (2007). "Real-Time PCR in Microbiology." Caister Academic Press. [http://www.horizonpress.com/rtmic ISBN 978-1-904455-18-9]
* Wawrik B, Paul JH, Tabita FR (2002) Real-time PCR quantification of "rbcL" (ribulose-1,5-bisphosphate carboxylase/oxygenase) mRNA in diatoms and pelagophytes. Appl. Environ. Microbiol. 68:3771-3779.
*External links
* [http://www.pathooligodb.com/ PathoOligoDB: A free qPCR Oligo database for pathogens]
* [http://pathmicro.med.sc.edu/pcr/realtime-home.htm Real Time PCR Tutorial] by Dr Margaret Hunt, University of South Carolina, September 5, 2006
* [http://www.gene-quantification.info/ www.gene-quantification.info] all about real-time qPCR and qRT-PCR
* [http://www.rt-pcr.com Real-time PCR literature] - Current literature
* [http://www.scanelis.com/webpages.aspx?rID=679 Real-time PCR Animation] - PCR and Real-time PCR principles and comparison
* [http://realtimepcr.dk realtimepcr.dk] Real time PCR experinces from researchers from the university of Copenhagen, Denmark.
* [http://www.primerdesign.co.uk/new_to_real_time.asp Beginners guide to real-time PCR ] Beginners guide to real-time PCR by PrimerDesign Ltd
Wikimedia Foundation. 2010.