Mass-analyzed ion kinetic energy spectrometry

Mass-analyzed ion kinetic energy spectrometry

Mass-analyzed ion kinetic energy spectrometry (MIKES) is a mass spectrometry technique by which mass spectra are obtained from a sector mass spectrometer that incorporates at least one magnetic sector plus one electric sector in reverse geometry (the beam first enters the magnetic sector).cite journal |author=Soltero-Rigau E, Kruger TL, Cooks RG |title=Identification of barbiturates by chemical ionization and mass-analyzed ion kinetic energy spectrometry |journal=Anal. Chem. |volume=49 |issue=3 |pages=435–42 |year=1977 |pmid=842853 |doi=] cite journal |author=Easton C, Johnson DW, Poulos A |title=Determination of phospholipid base structure by CA MIKES mass spectrometry |journal=J. Lipid Res. |volume=29 |issue=1 |pages=109–12 |year=1988 |pmid=3356947 |doi=] cite journal |author=Cooks RG, Kondrat RW, Youssefi M, McLaughlin JL |title=Mass-analyzed ion kinetic energy (MIKE) spectrometry and the direct analysis of coca |journal=J Ethnopharmacol |volume=3 |issue=2-3 |pages=299–312 |year=1981 |pmid=7242113 |doi=] The accelerating voltage, "V", and the magnetic flux density, "B", are set to select the precursor ions of a particular "m/z". The precursor ions then to dissociate or react in an electric field-free region between the two sectors. The ratio of the kinetic energy to charge of the product ions are analyzed by scanning the electric sector field "E". The width of the product ion spectrum peaks is related to the kinetic energy release distribution for the dissociation process. cite journal|title=Analysis of a mass-analyzed ion kinetic energy profile. II. Systematic determination of the kinetic energy release distribution|journal=Rapid Communications in Mass Spectrometry|date=1992|first=Chul |last=Yeh|coauthors= Myung Soo Kim|volume=6|issue=4|pages=293–297|doi= 10.1002/rcm.1290060414|url=http://www3.interscience.wiley.com/cgi-bin/fulltext/110446642/PDFSTART|format=PDF|accessdate=2008-03-30 ]

ee also

*Gas phase ion chemistry
*R. Graham Cooks

References

Bibliography

*cite book |author=Jacques Momigny; Eugen Illenberger |title=Gaseous Molecular Ions: An Introduction To Elementary Processes Induced By Ionization (Topics in Physical Chemistry) |publisher=Steinkopff |location=Darmstadt |year=1999 |pages= |isbn=3-7985-0870-4 |oclc= |doi=


Wikimedia Foundation. 2010.

Игры ⚽ Поможем решить контрольную работу

Look at other dictionaries:

  • Mass-analyzed ion-kinetic-energy spectrometry — MIKES redirects here. For other uses, see Mikes. Mass analyzed ion kinetic energy spectrometry (MIKES) is a mass spectrometry technique by which mass spectra are obtained from a sector instrument that incorporates at least one magnetic sector… …   Wikipedia

  • Tandem mass spectrometry — Tandem mass spectrometry, also known as MS/MS, involves multiple steps of mass spectrometry selection, with some form of fragmentation occurring in between the stages. [IUPAC gold book definition of tandem mass spectrometer… …   Wikipedia

  • Gas phase ion chemistry — is a field of science encompassed dually within both Chemistry and Physics. It is the science that studies ions and molecules in the gas phase, most often enabled by some form of mass spectrometry. By far the most important application for this… …   Wikipedia

  • Mass spectrometry — (MS) is an analytical technique that measures the mass to charge ratio of charged particles.[1] It is used for determining masses of particles, for determining the elemental composition of a sample or molecule, and for elucidating the chemical… …   Wikipedia

  • mass spectrometry — or mass spectroscopy Analytic technique by which chemical substances are identified by sorting gaseous ions by mass using electric and magnetic fields. A mass spectrometer uses electrical means to detect the sorted ions, while a mass spectrograph …   Universalium

  • Sector instrument — A five sector mass spectrometer A sector instrument is a general term for a class of mass spectrometer that uses a static electric or magnetic sector or some combination of the two (separately in space) as a mass analyzer.[1] A popular… …   Wikipedia

  • Mike's — may be:*Mike s Hard Lemonade Co., a manufacturer of alcoholic beverages *Mikes (restaurant), a restaurant chain in Eastern CanadaMIKES may be: *Mass analyzed ion kinetic energy spectrometry, a mass spectrometry technique …   Wikipedia

  • Time-of-flight mass spectrometry — (TOFMS) is a method of mass spectrometry in which ions are accelerated by an electric field of known strength. [Stephens, W. E., [http://link.aps.org/abstract/PR/v69/p674/s2 A Pulsed Mass Spectrometer with Time Dispersion] Phys. Rev. , 1946, 69 …   Wikipedia

  • Static secondary ion mass spectrometry — Static secondary ion mass spectrometry, or static SIMS is a technique for chemical analysis including elemental composition and chemical structure of the uppermost atomic or molecular layer of a solid which may be a metal, semiconductor or… …   Wikipedia

  • Secondary ion mass spectrometry — Infobox chemical analysis name = Secondary ion mass spectrometry caption =CAMECA IMS3f Magnetic SIMS Instrument acronym = SIMS classification =Mass spectrometry analytes = Solid surfaces, thin films related = Fast atom bombardment… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”