- Electrorheological fluid
Electrorheological (ER) fluids are suspensions of extremely fine non-conducting particles (up to 50
micrometre s diameter) in an electrically insulatingfluid . The apparentviscosity of these fluids changes reversibly by an order of up to 100,000 in response to anelectric field . For example, a typical ER fluid can go from the consistency of aliquid to that of agel , and back, with response times on the order ofmillisecond s. The effect is sometimes called the Winslow effect, after its discoverer the American inventor Willis Winslow, who obtained a US patent on the effect in1947 [US patent|2417850: Winslow, W. M.: 'Method and means for translating electrical impulses into mechanical force', 25 March 1947 ] and wrote an article published in1949 [cite journal | last = Winslow | first = Willis M. | title = Induced fibration of suspensions | journal = J. Appl. Phys. | volume = 20 | pages = 1137–1140 | year = 1949 | doi = 10.1063/1.1698285 ] .Applications
The normal application of ER fluids is in fast acting hydraulic valves [ cite journal | last = Simmonds | first = AJ | title = Electro-rheological valves in a hydraulic circuit | journal = IEE Proceedings-D | volume = 138 | issue = 4 | pages = 400–404 | month = July | year = 1991 ] and
clutch es, with the separation between plates being in the order of 1 mm and the appliedpotential being in the order of 1 kV. In simple terms, when the electric field is applied, an ER hydraulic valve is shut or the plates of an ER clutch are locked together, when the electric field is removed the ER hydraulic valve is open or the clutch plates are disengaged. Other common applications are in ERbrakes [ cite conference | last = Seed | first = M | coauthors = Hobson, GS; Tozer, RC; Simmonds, AJ | title = Voltage-controlled Electrorheological brake | booktitle = Proc. IASTED Int. Symp. Measurement, Sig. Proc. and Control | publisher = ACTA Press | pages = Paper No. 105-092-1 | date = Sept. 1986 | location = Taormina, Italy ] (think of a brake as a clutch with one side fixed) andshock absorbers [ cite journal | last = Stanway | first = R | coauthors = Sproston, JL; El-Wahed, AK | title = Applications of electro-rheological fluids in vibration control: a survey | journal = Smart Mater. Struct | volume = 5 | pages = 464–482 | month = August | year = 1996 | doi = 10.1088/0964-1726/5/4/011 ] (which can be thought of as closed hydraulic systems consisting of a valve with no external pump).There are many novel uses for these fluids, including use in the US army's planned [http://www.defense-update.com/features/du-4-04/FFW.htm future force warrior] project. They plan to create bulletproof vests using an ER fluid because the ability to soak the fluid into cloth creates the potential for a very light vest that can change from a normal cloth into a hard covering almost instantaneously. Other potential uses are in [http://cat.inist.fr/?aModele=afficheN&cpsidt=14040048 accurate abrasive polishing] and as
haptic controllers and tactile displays [ cite journal | last = Liu | first = Y | coauthors = Davidson, R; Taylor, P| title = Investigation of the touch sensitivity of ER fluid based tactile display | journal = Proceedings of SPIE, Smart Structures and Materials: Smart Structures and Integrated Systems | volume = 5764 | issue = | pages = 92–99 | year = 2005 ] .ER fluid has also been proposed to have potential applications in
flexible electronics , with the fluid incorporated in elements such as rollable screens and keypads, in which the viscosity-changing qualities of the fluid allowing the rollable elements to become rigid for use, and flexible to roll and retract for storing when not in use. Motorola filed a patent application formobile device applications in 2006. [ [http://www.unwiredview.com/2008/01/25/foldable-rollable-phone-from-motorola/ Foldable/ rollable phone from Motorola] ]The ER effect
The change in apparent viscosity is dependent on the applied
electric field , i.e. the potential divided by the distance between the plates. The change is not a simple change inviscosity , hence these fluids are now known as ER fluids, rather than by the older term Electro Viscous fluids. The effect is better described as an electric field dependent shearyield stress . When activated an ER fluid behaves as aBingham plastic (a type ofviscoelastic material), with a yield point which is determined by the electric field strength. After the yield point is reached, the fluid shears as afluid , i.e. the incrementalshear stress is proportional to the rate of shear (in aNewtonian fluid there is no yield point and stress is directly proportional to shear). Hence the resistance to motion of the fluid can be controlled by adjusting the applied electric field.ER fluid composition and theory
ER fluids are a type of
smart fluid . A simple ER fluid can be made by mixingcornflour in a light vegetable oil or (better)Silicone oil .There are two main theories to explain the effect: the interfacial tension or 'water bridge' theory [ cite journal | last = Stangroom | first = JE | title = Electrorheological Fluids | journal = Phys. Technol. | volume = 14 | issue = | pages = 290–296 | year = 1983 | doi = 10.1088/0305-4624/14/6/305 ] , and the
electrostatic theory. The water bridge theory assumes a three phase system, the particles contain the third phase which is another liquid (e.g. water) immiscible with the main phase liquid (e.g. oil). With no applied electric field the third phase is strongly attracted to and held within the particles. This means the ER fluid is a suspension of particles, which behaves as a liquid. When an electric field is applied the third phase is driven to one side of the particles by electroosmosis and binds adjacent particles together to form chains. This chain structure means the ER fluid has become a solid. The electrostatic theory assumes just a two phase system, withdielectric particles forming chains aligned with an electric field in an analogous way to howmagnetorheological fluid (MR) fluids work. An ER fluid has been constructed with the solid phase made from a conductor coated in an insulator [ cite journal | last = Tam | first = W Y | coauthors = Yi G H; Wen, W; Ma H; Sheng P| title = New Electrorheological Fluid: Theory and Experiment | journal = Phys. Rev. Lett. | volume = 78 | issue = 15 | pages = 2987–2990 | month = April | year = 1997| doi = 10.1103/PhysRevLett.78.2987 ] . This ER fluid clearly cannot work by the water bridge model. However, although demonstrating that some ER fluids work by theelectrostatic effect, it does not prove that all ER fluids do so. The advantage of having an ER fluid which operates on theelectrostatic effect is the elimination of leakage current, i.e. potentially there is noDC current . Of course, since ER devices behave electrically ascapacitors , and the main advantage of the ER effect is the speed of response, anAC current is to be expected.The particles are electrically active. They can be
ferroelectric or, as mentioned above, made from a conducting material coated with an insulator, or electro-osmotically active particles. In the case of ferroelectric or conducting material, the particles would have a highdielectric constant . There may be some confusion here as to the dielectric constant of a conductor, but "if a material with a high dielectric constant is placed in an electric field, the magnitude of that field will be measurably reduced within the volume of the dielectric" [http://en.wikipedia.org/wiki/Dielectric_constant] , and since theelectric field is zero in an ideal conductor, then in this context the dielectric constant of a conductor is infinite.Another factor that influences the ER effect is the geometry of the
electrode s. The introduction of parallel grooved electrodes showed slight increase in the ER effect but perpendicular grooved electrodes doubled the ER effect [ cite journal | last = Georgiades | first = G | coauthors = Oyadiji, SO| title = Effects of electrode geometry on the performance of electrorheological fluid valves | journal = Journal of Intelligent Material Systems and Structures | volume = 14 | issue = 2 | pages = 105–111 | year = 2003| doi = 10.1177/1045389X03014002006 ] . A much larger increase in ER effect can be obtained by coating the electrodes with electrically polarisable materials. This turns the usual disadvantage ofdielectrophoresis into a useful effect. It also has the effect of reducing leakage currents in the ER fluid [ Monkman G.J. ‑ Addition of Solid Structures to Electrorheological Fluids ‑ Journal of Rheology ‑ Vol 35, pp. 1385-7, October 1991] .The giant electrorheological (GER) fluid was recently (2003) discovered, and is able to sustain higher yield strengths than many other ER fluids. The GER fluid consists of
Urea coatednanoparticle s ofBarium Titanium Oxalate suspended insilicone oil . The high yield strength is due to the highdielectric constant of the particles, the small size of the particles and theUrea coating. Another advantage of the GER is that the relationship between theelectrical field strength and theyield strength is linear after the electric field reaches 1 kV/mm. The GER is a high yield strength, but low electrical field strength and lowcurrent density fluid compared to many other ER fluids. The procedure for preparation of the suspension is given in [ cite journal | last = Wen | first = W | coauthors = Huang, X; Yang, S; Lu, K; Sheng, P | title = The giant electrorheological effect in suspensions of nanoparticles | journal = Nature Materials | volume = 2 | issue = 11 | pages = 727–730 | month = November | year = 2003 | doi = 10.1038/nmat993 ] . The major concern is the use ofoxalic acid for the preparation of the particles as it is a strongorganic acid .Problems and advantages
A major problem is that ER fluids are suspensions, hence in time they tend to settle out, so advanced ER fluids tackle this problem by means such as matching the densities of the solid and liquid components, or by using nanoparticles, which brings ER fluids into line with the development of
magnetorheological fluid s. Another problem is that the breakdown voltage of air is ~ 3 kV/mm, which is near the electric field needed for ER devices to operate.An advantage is that an ER device can control considerably more mechanical power than the electrical power used to control the effect, i.e. it can act as a power amplifier. But the main advantage is the speed of response, there are few other effects able to control such large amounts of mechanical or hydraulic power so rapidly.
Unfortunately, the increase in apparent viscosity experienced by most Electrorheological fluids used in shear or flow modes is relatively limited. The ER fluid changes from a Newtonian liquid to a partially crystaline "semi-hard slush". However, an almost complete liquid to solid phase change can be obtained when the electrorheological fluid additionally experiences compressive stress [ Monkman. G.J. - The Electrorheological Effect under Compressive Stress - Journal of Physics D: Applied Physics - Vol. 28, pp 588-593 - Institute of Physics, 1995. ] . This effect has been used to provide electrorheological Braille displays [ Monkman. G.J. ‑ An Electrorheological Tactile Display ‑ Presence (Journal of Teleoperators and Virtual Environments) ‑ Vol. 1, issue 2, pp. 219-228, MIT Press, July 1992. ] and very effective clutches [ Monkman. G.J. - Exploitation of compressive stress in electrorheological coupling - Mechatronics - Vol. 7, No. 1, pp. 27-36 - Pergamon February 1997.] .
See also
*
Continuum mechanics
*Ferrofluid
*Fluid mechanics
*Smart fluid
*magnetorheological fluid References
Wikimedia Foundation. 2010.