Auscultatory gap

Auscultatory gap

An auscultatory gap is the interval of pressure where Korotkoff sounds indicating true systolic pressure fade away and reappear at a lower pressure point during the manual measurement of blood pressure. The improper interpretation of this gap may lead to blood pressure monitoring errors: namely, an underestimation of systolic blood pressure and/or an overestimation of diastolic blood pressure.

The auscultatory gap can be mistaken for the silence that occurs when the cuff pressure exceeds the systolic pressure. In this setting, the true systolic pressure can be elucidated by palpating the radial artery pulse. It is therefore recommended to palpate and auscultate when manually recording a patient's blood pressure. Typically the blood pressure obtained via palpation is around 10 mmHg lower than the pressure obtained via auscultation. In general, the examiner can avoid being confused by an auscultatory gap by always inflating a blood pressure cuff to 20-40 mmHg higher than the pressure required to obliterate the brachial pulse.

There is evidence that auscultatory gaps are related to carotid atherosclerosis and to increased arterial stiffness in hypertensive patients, independent of age. Another cause is believed to be venous congestion within the limb that is being used for the measurement. Although these observations need to be confirmed prospectively, they suggest that auscultatory gaps may have prognostic relevance. [Cite journal| last = Cavallini | first = M. Chiara | coauthors = et al. | date = 1996-05-15 | title = Association of the Auscultatory Gap with Vascular Disease in Hypertensive Patients | journal = Annals of Internal Medicine | volume = 124 | issue = 10 | pages = 877–883 | url= http://www.annals.org/cgi/content/full/124/10/877 | pmid = 8610916]

Notes


Wikimedia Foundation. 2010.

Игры ⚽ Нужен реферат?

Look at other dictionaries:

  • auscultatory gap — a silent period in the knocking sounds heard with a stethoscope over an artery, between the systolic and diastolic blood pressures, when the blood pressure is measured with a sphygmomanometer. * * * time in which sound is not heard in the… …   Medical dictionary

  • auscultatory gap — a silent period in the knocking sounds heard with a stethoscope over an artery, between the systolic and diastolic blood pressures, when the blood pressure is measured with a sphygmomanometer …   The new mediacal dictionary

  • Провал Аускультативный (Auscultatory Gap) — зона молчания период, во время которого звуки, слышимые в стетоскоп, расположенный над артерией, и показывающие истинное систолическое давление, исчезают и снова появляются при более низких значениях давления, показывая диастолическос давление;… …   Медицинские термины

  • gap — 1. A hiatus or opening in a structure. 2. An interval or discontinuity in any series or sequence. 3. (G) A period in the cell cycle. g. 1 (G1) in the somatic …   Medical dictionary

  • silent gap — auscultatory g …   Medical dictionary

  • ПРОВАЛ АУСКУЛЬТАТИВНЫЙ — (auscultatory gap) зона молчания период, во время которого звуки, слышимые в стетоскоп, расположенный над артерией, и показывающие истинное систолическое давление, исчезают и снова появляются при более низких значениях давления, показывая… …   Толковый словарь по медицине

  • Korotkoff sounds — Korotkoff are the sounds that medical personnel listen for when they are taking blood pressure using a non invasive procedure. They are named after Dr. Nikolai Korotkoff, a Russian physician who described them in 1905, when he was working at the… …   Wikipedia

  • Timeline of Russian inventions and technology records — The Hall of Space Technology in the Tsiolkovsky State Museum of the History of Cosmonautics, Kaluga, Russia. The exhibition includes the models and replicas of the following Russian inventions: the first satellite, Sputnik 1 (a ball under the… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”