A transdermal patch or skin patch is a
medicated adhesive patch that is placed on theskin to deliver a specificdose of medication through the skin and into thebloodstream . Often, this promotes healing to an injured area of the body. An advantage of a transdermal drug delivery route over other types such as oral, topical, etc is that it provides a controlled release of the medicament into the patient. A disadvantage to development however, stems from the fact that the skin is a very effective barrier. A wide variety of pharmaceuticals can be delivered by transdermal patches. The first commercially available prescription patch was approved by the U.S.Food and Drug Administration in December 1979, which administeredscopolamine formotion sickness . [cite web | url = http://www.fda.gov/bbs/topics/consumer/CON00112.html | title = Patches, Pumps and Timed Release: New Ways to Deliver Drugs | last = Segal | first = Marian | publisher =Food and Drug Administration |accessdate = 2007-02-24] [cite web | url = http://www.fda.gov/bbs/topics/ANSWERS/ANS00834.html | title = FDA approves scopolamine patch to prevent peri-operative nausea | publisher =Food and Drug Administration | date =1997-11-10 |accessdate = 2007-02-12]Before these patches go into the market, they have to be carefully studied. One way to study these patches are through the use of Franz Diffusion Cell systems. This system is used to study the effects of temperature on the permeated amount of a specific drug on a certain type of membrane, which in this case would be the membrane that is used in the patches. A Franz Diffusion Cell system is composed of a receptor and a donor cell. In many of these research studies the following procedure is used. The donor cell is set at a specific temperature (the temperature of the body), while the receptor cell is set at different one (temperature of the environment).
Different runs are performed using different temperatures to study the impact of temperature on the release of a certain medicament through a certain type of membrane. Although different concentrations of the medicament are used in this study, they do not affect the amount permeated through the membrane (the process is constant). From Chemical kinetics it’s concluded that these studies are zero order, since the concentration plays no role in the permeated amount through the membrane.
The highest selling transdermal patch in the United States was the
nicotine patch which releasesnicotine to help with cessation oftobacco smoking , however,fentanyl (analgesic for severe pain) is now the number one selling patch. Other skin patches administerestrogen formenopause . This also seems to preventosteoporosis after menopause.Nitroglycerin patches for angina andlidocaine patches to relieve the peripheral pain of shingles ("herpes zoster ") are also available. Recent developments expanded their use to the delivery of hormonal contraceptives, antidepressants and evenpain killer s andstimulants forAttention Deficit Hyperactivity Disorder /ADHD . The first commercially available vapour patch to reduce smoking was approved in Europe in 2007. The patches release essential oils that help the smoker to reduce gradually the number of cigarettes instead of stopping the smoking abruptly.Some pharmaceuticals must be combined with substances, such as
alcohol , within the patch to increase their ability to penetrate the skin in order to be used in a transdermal patch. Others can overwhelm the body if applied in only one place, and are often cut into sections and applied to different parts of the body to avoid this, such as nitroglycerin. Many molecules, however, such asinsulin , are too large to pass through the skin.In 2005, the Food and Drug Administration announced that they are investigating reports of death and other serious adverse events related to
narcotic overdose in patients usingDuragesic , thefentanyl transdermal patch for pain control. The Duragesic product label was subsequently updated to add safety information in June 2005. [cite web | url = http://www.fda.gov/cder/drug/InfoSheets/HCP/fentanylHCP.htm | title = FDA ALERT (07/2005): Narcotic Overdose and Death | publisher =Food and Drug Administration | date =2005-07-15 |accessdate = 2007-02-24]Components
The main components to a transdermal patch are:
*Liner - Protects the patch during storage. The liner is removed prior to use.
*Drug - Drug solution in direct contact with release liner
*Adhesive - Serves to adhere the components of the patch together along with adhering the patch to the skin
*Membrane - Controls the release of the drug from the reservoir and multi-layer patches
*Backing - Protects the patch from the outer environmentTypes
There are four main types of transdermal patches listed below.
Single-layer Drug-in-Adhesive
The adhesive layer of this system also contains the drug. In this type of patch the adhesive layer not only serves to adhere the various layers together, along with the entire system to the skin, but is also responsible for the releasing of the drug. The adhesive layer is surrounded by a temporary liner and a backing.
Multi-layer Drug-in-Adhesive
The multi-layer drug-in adhesive patch is similar to the single-layer system in that both adhesive layers are also responsible for the releasing of the drug. The multi-layer system is different however that it adds another layer of drug-in-adhesive, usually separated by a membrane (but not in all cases). This patch also has a temporary liner-layer and a permanent backing.
Reservoir
Unlike the Single-layer and Multi-layer Drug-in-adhesive systems the reservoir transdermal system has a separate drug layer. The drug layer is a liquid compartment containing a drug solution or suspension separated by the adhesive layer. This patch is also backed by the backing layer. In this type of system the rate of release is zero order
Matrix
The Matrix system has a drug layer of a semisolid matrix containing a drug solution or suspension. The adhesive layer in this patch surrounds the drug layer partially overlaying it.
Vapour Patch
In this type of patch the adhesive layer not only serves to adhere the various layers together but also to release vapour. The vapour patches are new on the market and they release essential oils for up to 6 hours. The vapour patches release essential oils and are used in cases of decongestion mainly. Other vapour patches on the market are controller vapour patches that improve the quality of sleep. Vapour patches that reduce the quantity of cigarettes that one smokes in a month are also available on the market.
Regulatory aspects
A transdermal patch is classified by the U.S. Food and Drug Administration as a combination product, consisting of a
medical device combined with adrug or biological product that the device is designed to deliver. Prior to sale in the United States, any transdermal patch product must apply for and receive approval from the Food and Drug Administration, demonstrating safety and efficacy for its intended use.Notes
Further reading
*cite web | url = http://www.fda.gov/cder/foi/label/2001/17874s27lbl.pdf | title = Transderm Scōp | publisher =
Food and Drug Administration | date=1998 | accessdate = 2007-02-12 Languageicon|PDF|Portable Document Fileee also
*
Route of administration
*Metered dose transdermal spray External links