- Wastewater quality indicators
Wastewater quality indicators such as the
biochemical oxygen demand (BOD) and thechemical oxygen demand (COD) are essentiallylaboratory test s to determine whether or not a specificwastewater will have a significant adverse effect uponfish or uponaquatic plant life.Wastewater biochemical oxygen demand and chemical oxygen demand
Any oxidizable material present in a natural waterway or in an industrial wastewater will be oxidized both by biochemical (bacterial) or chemical processes. The result is that the oxygen content of the water will be decreased. Basically, the reaction for biochemical oxidation may be written as:
:Oxidizable material + bacteria + nutrient + O2 → CO2 + H2O + oxidized inorganics such as NO3 or SO4
Oxygen consumption by reducing chemicals such as sulfides and nitrites is typified as follows:
:S-- + 2 O2 → SO4--
:NO2- + ½ O2 → NO3-
Since all natural waterways contain bacteria and nutrient, almost any waste compounds introduced into such waterways will initiate biochemical reactions (such as shown above). Those biochemical reactions create what is measured in the laboratory as the Biochemical Oxygen Demand (BOD).
Oxidizable chemicals (such as reducing chemicals) introduced into a natural water will similarly initiate chemical reactions (such as shown above). Those chemical reactions create what is measured in the laboratory as the Chemical Oxygen Demand (COD).
Both the BOD and COD tests are a measure of the relative oxygen-depletion effect of a waste contaminant. Both have been widely adopted as a measure of pollution effect. The BOD test measures the oxygen demand of biodegradable pollutants whereas the COD test measures the oxygen demand of biogradable pollutants plus the oxygen demand of non-biodegradable oxidizable pollutants.
The so-called 5-day BOD measures the amount of oxygen consumed by biochemical oxidation of waste contaminants in a 5-day period. The total amount of oxygen consumed when the biochemical reaction is allowed to proceed to completion is called the Ultimate BOD. The Ultimate BOD is too time consuming, so the 5-day BOD has almost universally been adopted as a measure of relative pollution effect.
There are also many different COD tests. Perhaps, the most common is the 4-hour COD.
It should be emphasized that there is no generalized correlation between the 5-day BOD and the Ultimate BOD. Likewise, there is no generalized correlation between BOD and COD. It is possible to develop such correlations for a specific waste contaminant in a specific wastewater stream, but such correlations cannot be generalized for use with any other waste contaminants or wastewater streams.
The laboratory test procedures for the determining the above oxygen demands are detailed in the following sections of the "Standard Methods For the Examination Of Water and Wastewater" available at [http://www.standardmethods.org www.standardmethods.org] :
:* 5-day BOD and Ultimate BOD: Sections 5210B and 5210C:* COD: Section 5220
Further reading
* Tchobanoglous, M, Mannarino, F L, & Stensel, H D (2003). "Wastewater Engineering (Treatment Disposal Reuse) / Metcalf & Eddy, Inc", 4th Edition, McGraw-Hill Book Company. ISBN 0-07-041878-0.
*Beychok, Milton R. (1967). "
Aqueous Wastes from Petroleum and Petrochemical Plants ", 1st Edition, John Wiley & Sons, LCCN 67019834.ee also
*
Biochemical oxygen demand
*Chemical oxygen demand
*Conventional pollutant
*Dissolved oxygen
*Hypoxia (environmental)
*Industrial water treatment
*Wastewater
*Water pollution
*Water quality
*Water treatment External links
* [http://epa.gov/ostwater/guide/pharm/techdev/ch5.pdf Discussion of BOD and COD] (use BOD as the keyword in the pdf search function)
* [http://www.ipcri.org/watconf/papers/akram.pdf Discussion of BOD and COD] (use BOD as the keyword in the pdf search function)
* [http://www.dnr.state.wi.us/org/water/wm/ww/biophos/2sample.htm More about COD and BOD] (scroll to section on "Advantage of using COD over BOD")
* [http://www.bsr.org/CSRResources/Environment/WQG_Pollutant_FactSheet.pdf Discussion of oxygen demand] (use Oxygen Demand as the keywords in the pdf search function)