- Telectronics Pty Ltd
Telectronics Pty Ltd was an Australian company best known for its role in developing the pacemaker. In 1988 the business was acquired by Pacific Dunlop.cite web | last = Smith | first = Ailie | authorlink = | coauthors = | year = 2000 | url = http://www.austehc.unimelb.edu.au/asaw/biogs/A000354b.htm | title = Telectronics Holdings Limited ( - 1988) | work = Australian Science at Work (Corporate entry) | publisher = Australian Science and Technology Heritage Centre | accessdate = 2006-12-04 and also cite web | last = Smith | first = Ailie | authorlink = | coauthors = | year = 2006 | url = http://www.austehc.unimelb.edu.au/asaw/biogs/A000347b.htm | title = Telectronics Pty Ltd (1963 - 1996) | work = Australian Science at Work (Corporate entry) | publisher = Australian Science and Technology Heritage Centre | accessdate = 2006-12-04] However, claims resulting from the sale of faulty pacemaker electrode leads led to eventual sale of the assets of the company and Pacific Dunlop restructuring itself into Ansell.
Development of the pacemaker
Telectronics Pty Limited was incorporated in Sydney, Australia, in 1963"Telectronics and The History Of Pacemaking In Australia", Wickham G G, Jeffcoat KW, 1987 manuscript held by http://www.austehc.unimelb.edu.au. University Of Melbourne .(www.austehc.unimelb.edu.au.)] "Telectronics The Early Years" Gray N D, Gray C J, 1994. ISBN 0-646-15134-7.] by engineers
Noel Gray andGeoffrey Wickham initially designing and manufacturing industrial and scientific instruments but diversifying into medical electronics and commencing cardiac pacemaker research in 1964.cite news | first= Robert | last= Foot | author= | url= http://www.smh.com.au/news/obituaries/rare-breed-of-native-industrialist/2006/04/13/1144521458280.html?page=fullpage#contentSwap1
title=Rare breed of native industrialist: Paul Murray Trainor, AO Industrialist 1927-2006
work=Obituaries | publisher=Sydney Morning Herald | date=2006-04-14 | accessdate=2006-12-04] .cite web | last = | first = | authorlink = | coauthors = | year = | url = http://www.powerhousemuseum.com/collection/database/?irn=331255 | title = Display panels tracing the history of 'Telectronics' cardiac pacemakers and defibrillators, 1990 | work = Objects from the collection of the Powerhouse Museum, Sydney, Australia | publisher =Powerhouse Museum | accessdate = 2006-12-04] The corporate name was derived from "Television and Electronic Services", operated by Noel Gray as a sole trader from 1959-1964.The company made significant contributions to pacemaker technology including the first definition of the relationship between surface area of the heart electrodes & pacing pulse characteristics, the first use of
integrated circuits and the firsthermetic titanium encapsulation.The company's first model, designated P1, was implanted in three
volunteer terminally ill patients in December '64 - January'65, while 2 control samples were retained in a 37 °C. saline bath. This initial design used PNP - NPN electronics to deliver a 2.0millisecond pulse to the Jeffcoatepicardial electrodes , and was powered by 4 Mallory mercuric oxide-zinc cells (mercury battery ), all encapsulated inepoxy resin with a final dip coat of a mix of epoxy andtitanium dioxide . All 3 implants failed in ability to maintain capture of the heart after periods of up to 35 weeks. These failures were later proven to be due to the excessively large surface area of the electrodes.The initial clinical experience led to further
animal research usingmongrel dogs at the laboratories of theUniversity of Sydney medical school and at theRoyal North Shore Hospital 's Wellcome laboratory. In this research measurements were made of electrode impedance and pacing threshold energy over a range of pulse voltages and pulse widths, using intramyocardial electrodes of 10, 20 & 50 square millimeters surface area. The chronic measurements allowed plotting of the relationship between electrode surface area and pulse voltage/width, leading to a conclusion that an electrode area between 10 & 30 mm2 was optimum in terms of energy needed when combined with a pulse width of only 0.5 milliseconds.These characteristics were incorporated in the next design to be implanted in humans, the model P4, which employed 30 mm2 area intramyocardial electrodes (and later
transvenous pacing electrodes), a very conservative 7.5 volt pulse and for further conservatism a magnetically operated switch which could be actuated from outside the body to change the pulse width from 0.5 to 1.0 millisecond.
The 0.5 millisecond pulse width became the standard for later Telectronics models and became the approximate standard for all pacemaker manufacturers by the late 70's, until the evolution of externally programmable/monitorable pacemakers usingdigital electronics in the late 1980s.Research also included
dissection andThe first hermetically sealed models were the P8-9-10 of 1971Wickham G G, Cowdery D J, " An Hermetically Sealed Implantable Cardiac pacemaker", Proceedings of the 9th International Conference On Medical & Biological Engineering, Melbourne, 1971] using
titanium encapsulation withceramic terminal insulation, developed by David J Cowdery. Bonding of the ceramic was performed usingvacuum brazing and an alloy of titanium/nickel with a small % of copper. The final hermetic sealing of the titanium capsule was performed by aTIG tungsten-inert gasargon welding process within a largebell jar on an automated analogue controlled machine designed and built by Cowdery. These were the first pacemakers using the conventional battery to be hermetically sealed. Gas products of the battery were absorbed by a chemical 'getter'. Some examples of these models survived to beyond 5 years. By the late 80's TIG welding was replaced bylaser welding .In 1971 Telectronics commenced testing samples of a new type of energy source for pacemakers, the lithium cell (
lithium battery ) being developed byWilson Greatbatch and in 1972 commenced development of a range of integrated circuits capable of operation from the 2.8 volts of the cell while providing a stimulating pulse of 4.5 volts. The combined technologies of a lithium cell, integrated circuits, hermetic titanium casing and an 0.5 millisecond pulse was first used clinically in 1974 in the model 120 pacemaker which wasstate of the art for that time. In 1981 a study of 28'669 Telectronics lithium powered implants showed a cumulative survival of 99.88% and aMTBF of 12'260 months.Telectronics publication "QRS", July 1981.]Control of Telectronics was gained in 1967 by Nucleus Holdings. The company was incorporated in the USA in 1974, and in 1977 commenced US manufacture from the former
General Electric facility inMilwaukee , later relocating toDenver . A manufacturing plant was also established atChatellerault France, in 1978.Pacific Dunlop
In 1988
Nucleus Limited was acquired by Pacific Dunlop. At that time Nucleus Limited contained offshoots such as Telectronics, Medtel, Ausonics, Domedica and Cochlear Pty Ltd. Cochlear Limited which developed thecochlear implant was floated on the Australian stock market. Pacific Dunlop was hoping to diversify away from so-called rustbelt companies. At the time of acquisition, Telectronics was number 2 in the worldwide pacemaker market. [ [http://www.austehc.unimelb.edu.au/tia/889.html#3600 "Technology in Australia 1788-1988" Melbourne University page 889] ] cite web | last = Smith | first = Ailie | authorlink = | coauthors = | year = 2006 | url = http://www.austehc.unimelb.edu.au/asaw/biogs/A000352b.htm | title = Nucleus Limited (1965 - 1988) | work = Australian Science at Work (Corporate entry) | publisher = Australian Science and Technology Heritage Centre | accessdate = 2006-12-04] [cite news|url=http://newsstore.smh.com.au/apps/viewDocument.ac?page=1&sy=smh&kw=TELECTRONICS+TO+BE+NO+2+IN+PACEMAKER+MARKET+&pb=all_ffx&dt=selectRange&dr=entire&so=relevance&sf=headline&sf=text&rc=20&rm=200&sp=nrm&clsPage=1&docID=news870217_0029_6293 |title= Telectronics to be no 2 in pacemaker market |publisher= Sydney Herald |date=1987-02-17 |accessdate=2006-12-19]In January 1995, Telectronics was forced to recall thousands of pacemakers by the
Food and Drug Administration leading to the company having to eventually settle legal claims at a cost of hundreds of millions of dollars.cite news | first= Gina | last=Kolata | author= | url= http://query.nytimes.com/gst/fullpage.html?res=9501E6DA103AF935A35757C0A96E958260&sec=health&pagewanted=all
title= In Fixing Faulty Medical Devices, the Cure Can Be Worse Than the Disease | work= Health | publisher= New York Times | date=1998-04-06 | accessdate=2006-12-04] The cause of the recall was a "J lead" electrode inherited by the company in acquisition of pacemaker manufacturerCordis Corporation of Miami.In 1996 Pacific Dunlop sold most of the assets of Telectronics Limited toSt Jude Medical ofMinnesota [cite web | last = | first = | authorlink = | coauthors = | year = | url = http://www.ansell.com/company/history.pdf | title = History of Pacific Dunlop Limited | format = pdf | work = | publisher = ansell.com | accessdate = 2006-12-04] and Telectronics Pty Limited is now a shelf company TPL Pty Limited. Pacific Dunlop restructured in 2001 becomingAnsell with the high cost of the Telectronics settlement being a contributing factor in the decision.fact|date=January 2008References
Wikimedia Foundation. 2010.