Signalling Connection Control Part

Signalling Connection Control Part

The Signalling Connection Control Part (SCCP) is a network layer [ [http://www.itu.int/T-REC-Q.1400/en/ ITU-T Recommendation Q.1400] .] protocol that provides extended routing, flow control, segmentation, connection-orientation, and error correction facilities in Signaling System 7 telecommunications networks. SCCP relies on the services of MTP for basic routing and error detection.

Published specification

The base SCCP specification is defined by the ITU-T, in recommendations [http://www.itu.int/rec/T-REC-Q.711/en/ Q.711] to [http://www.itu.int/rec/T-REC-Q.714/en/ Q.714] , with additional information to implementors provided by [http://www.itu.int/rec/T-REC-Q.715/en/ Q.715] and [http://www.itu.int/rec/T-REC-Q.716/en/ Q.716] . [http://www.itu.int/rec/T-REC-Q/en/ ITU-T Q-Series Recommendations] .] There are, however, regional variations defined by local standards bodies. In the United States, ANSI publishes its modifications to [http://www.itu.int/rec/T-REC-Q.713/en/ Q.713] as ANSI T1.112. The TTC publishes as JT-Q.711 to JT-Q.714, and Europe ETSI publishes " [http://webapp.etsi.org/workprogram/Report_WorkItem.asp?WKI_ID=6605 ETSI EN 300-009-1] :" both of which document their modifications to the ITU-T specifications.

Routing facilities beyond MTP

Although MTP provides routing capabilities based upon the Point Code, SCCP allows routing using a Point Code and Subsystem number or a Global Title.

A Point Code is used to address a particular node on the network, whereas a Subsystem number addresses a specific application available on that node. SCCP employs a process called Global Title Translation to determine Point Codes from Global Titles so as to instruct MTP on where to route messages.

SCCP messages contain parameters which describe the type of addressing used, and how the message should be routed:

* Address Indicator
** "Subsystem indicator": The address includes a Subsystem Number
** "Point Code indicator": The address includes a Point Code
* Global title indicator
** "No Global Title"
** "Global Title includes Translation Type (TT), Numbering Plan Indiciator (NPI) and Type of Number (TON)"
** "Global Title includes Translation Type only"
* Routing indicator
** "Route using Global Title only"
** "Route using Point Code/Subsystem number"
* Address Indicator Coding
** "Address Indicator coded as national" (the Address Indicator is treated as international if not specified)

Protocol classes

SCCP provides 5 classes of protocol to its applications:
* Class 0: Basic connectionless
* Class 1: Sequenced connectionless
* Class 2: Basic connection-oriented
* Class 3: Flow control connection oriented
* Class 4: Error recovery and flow control connection oriented

The connectionless protocol classes provide the capabilities needed to transfer one Network Service Data Unit (NSDU) in the "data" field of an XUDT, LUDT or UDT message. When one connectionless message is not sufficient to convey the user data contained in one NSDU, a segmenting/reassembly function for protocol classes 0 and 1 is provided. In this case, the SCCP at the originating node or in a relay node provides segmentation of the information into multiple segments prior to transfer in the "data" field of XUDT (or as a network option LUDT) messages. At the destination node, the NSDU is reassembled.

The connection-oriented protocol classes (protocol classes 2 and 3) provide the means to set up signalling connections in order to exchange a number of related NSDUs. The connection-oriented protocol classes also provide a segmenting and reassembling capability. If an NSDU is longer than 255 octets, it is split into multiple segments at the originating node, prior to transfer in the "data" field of DT messages. Each segment is less than or equal to 255 octets. At the destination node, the NSDU is reassembled. [http://www.itu.int/rec/T-REC-Q.714/en ITU-T Recommendation Q.714] - Signalling connection control part procedures]

Class 0: Basic connectionless

The SCCP Class 0 protocol class is the most basic of the SCCP protocol classes. Network Service Data Units passed by higher layers to the SCCP in the originating node are delivered by the SCCP to higher layers in the destination node. They are transferred independently of each other. Therefore, they may be delivered to the SCCP user out-of-sequence. Thus, this protocol class corresponds to a pure connectionless network service. As a connectionless protocol, no network connection is established between the sender and the receiver.

Class 1: Sequenced connectionless

SCCP Class 1 builds on the capabilities of Class 0, with the addition of a sequence control parameter in the NSDU which allows the SCCP User to instruct the SCCP that a given stream of messages should be delivered in sequence. Therefore, Protocol Class 1 corresponds to an enhanced connectionless protocol with assurances of in-sequence delivery.

Class 2: Basic connection-oriented

SCCP Class 2 provides the facilities of Class 1, but also allows for an entity to establish a two-way dialog with another entity using SCCP.

Class 3: Flow control connection oriented

Class 3 service builds upon Class 2, but also allows for expedited (urgent) messages to be sent and received, and for errors in sequencing (segment re-assembly) to be detected and for SCCP to restart a connection should this occur.

Transport over IP Networks

In the SIGTRAN suite of protocols, there are two primary methods of transporting SCCP applications across Internet Protocol networks: SCCP can be transported indirectly using the "MTP level 3 User Adaptation" protocol (M3UA), a protocol which provides support for users of MTP-3—including SCCP. Alternatively, SCCP applications can operate directly over the "SCCP User Adaptation" protocol (SUA) which is a form of modified SCCP designed specifically for use in IP networking.

ITU-T also provides for the transport of SCCP users over Internet Protocol using the "Generic Signalling Transport" service specified in [http://www.itu.int/rec/T-REC-Q.2150.0/en/ Q.2150.0] , the "signalling transport converter" for SCTP specified in [http://www.itu.int/rec/T-REC-Q.2150.3/en/ Q.2150.3] and a specialized "Transport-Independent Signalling Connection Control Part" (TI-SCCP) specified in [http://www.itu.int/rec/T-REC-Q.2220/en/ T-REC-Q.2220] .TI-SCCP can also be used with the "Generic Signalling Transport" adapted for MTP3 and MTP3b as described in [http://www.itu.int/rec/T-REC-Q.2150.1/en/ Q.2150.1] , or adapted for SSCOP or SSCOPMCE as described in [http://www.itu.int/rec/T-REC-Q.2150.2/en/ Q.2150.2] .

References

External links

* [http://www.iec.org/online/tutorials/ss7/ SS7 Tutorial] - SS7 tutorial, including SCCP description.


Wikimedia Foundation. 2010.

Игры ⚽ Поможем написать реферат

Look at other dictionaries:

  • Signalling Connection Control Part — (abgekürzt SCCP) ist eine in Telekommunikationsnetzen wie dem Telefonnetz im Rahmen des Signalling System 7 (abgekürzt SS7) eingesetzte Vermittlungsschicht. Sie dient im Signalisierungsnetz dem Routing, der Fehlerkorrektur und Flusskontrolle und… …   Deutsch Wikipedia

  • Signalling System No. 7 — SS7 protocol suite OSI layer SS7 protocols Application INAP, MAP, IS 41... TCAP, CAP, ISUP, ... Network MTP Level 3 + SCCP Data link MTP Level 2 …   Wikipedia

  • Signalling System 7 — Das Signalling System #7, zu deutsch Signalisierungssystem Nummer 7, (im weiteren SS7 genannt) ist eine Sammlung von Protokollen und Verfahren für die Signalisierung in Telekommunikationsnetzen. Es kommt im öffentlichen Telefonnetz, in… …   Deutsch Wikipedia

  • Signalling System Number 7 — Signalisierung Unter Signalisierung versteht man in der Telekommunikation die Übertragung von Steuerinformationen. Einfache Signalisierungsinformation sind zum Beispiel klingeln oder Teilnehmer besetzt. Weiter gibt es Signalisierungsinformationen …   Deutsch Wikipedia

  • Mobile Application Part — Signalisierung Unter Signalisierung versteht man in der Telekommunikation die Übertragung von Steuerinformationen. Einfache Signalisierungsinformation sind zum Beispiel klingeln oder Teilnehmer besetzt. Weiter gibt es Signalisierungsinformationen …   Deutsch Wikipedia

  • ISDN User Part — The ISDN User Part or ISUP is part of the Signaling System #7 which is used to set up telephone calls in Public Switched Telephone Networks. It is specified by the ITU T as part of the Q.76x series, [ [http://www.itu.int/rec/T REC Q/en/ ITU T Q… …   Wikipedia

  • Mobile Application Part — SS7 protocol suite OSI layer SS7 protocols Application INAP, MAP, IS 41... TCAP, CAP, ISUP, ... Network MTP Level 3 + SCCP Data link MTP Level 2 …   Wikipedia

  • Subsystem number — Signalling Connection Control Part (SCCP) subsystem numbers are used to identify applications within network entities which use SCCP signalling. GSM and UMTS SSNs In Global System for Mobile Communications (GSM) and Universal Mobile… …   Wikipedia

  • Liste der Telekommunikationsstandards — Liste von Standards und Richtlinien aus der Telekommunikation. Inhaltsverzeichnis 1 ETSI 1.1 Nomenklatur 1.1.1 derzeit gültige Nomenklatur 1.1.2 vorherige Nomenklatur …   Deutsch Wikipedia

  • Signaling System 7 — Signaling System #7 (SS7) is a set of telephony signaling protocols which are used to set up most of the world s public switched telephone network telephone calls. The main purpose is to set up and tear down telephone calls. Other uses include… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”