- PRR S2
The
Pennsylvania Railroad 's class S2 was asteam turbine locomotive . Only one prototype was built, #6200. The S2 was the sole example of the6-8-6 wheel arrangement in theWhyte notation , featuring a six-wheelleading truck , eightdriving wheel s, and a six-wheeltrailing truck . The S2 design used a direct-drivesteam turbine ; the turbine drove the wheels via gearing, being geared to the center pair of axles with the outer two axles connected byside rod s. This had the advantage of simplicity. The disadvantage was that the turbine could not operate at optimal speeds over the locomotive's entire speed range. The S2 was the largest direct-drive turbine locomotive design ever built.It was originally intended for the locomotive to be a
4-8-4 , but wartime restrictions on exotic steel alloys meant that the locomotive became too heavy, and six-wheel leading and trailing trucks were needed. Two turbines were fitted, one for forward travel and a smaller one for reversing at speeds up to 22 mph. A large boiler with aBelpaire firebox and longcombustion chamber was fitted. Draft for the fire was provided through fans in thesmokebox , providing an even draft and exhausting through a unique quadruple stack. A Worthington-patternfeedwater heater was fitted for increased efficiency. Twin air pumps for train braking were fitted below the running boards beside the smokebox front, and a large radiator assembly at the nose cooled the compressed air. A very large tender, similar to that used on the PRR's other large passenger locomotives, the T1 and S1, was provided.In service, the locomotive proved to be powerful and capable, with ample reserves of power at speed and reasonable fuel economy. The smooth turbine drive was easy on the track and allowed more power to be delivered to the rails. The major disadvantage was that, while economical at speed, the locomotive was highly uneconomical at lower speeds. The turbine was optimised to run at its ideal speed range at above about 40 mph; below that, the locomotive used prodigious, wasteful amounts of steam and fuel. The boiler normally operated at 310 PSI, but low speed steam usage could cause the pressure to drop as low as 85 PSI. The increased fuel usage at slow speeds also caused the firebox to run hotter, which sometimes caused stay bolts to break.
The locomotive's various problems, and the by-then obvious advantages of the
diesel locomotive , ensured #6200 would never be duplicated. The locomotive was withdrawn from service in 1949 and scrapped in 1953.External links
* [http://crestlineprr.com/duplexexperimentals.html#s2 The Duplex and Experimental Steam Engines of the PRR]
Wikimedia Foundation. 2010.