The Inter-Island HVDC link (designation BEN-HAY A [ cite web|url= http://www.gridnewzealand.co.nz/f70,3566/3566_transmission-map-si.pdf |title= South Island Grid Map |accessdate= 2008-09-01. Short for "Benmore to Haywards line A". ] ) is the high voltage direct current connection between the two main islands of New Zealand, put into service in 1965. The abbreviation stands for High Voltage Direct Current. It was built with mercury arc rectifiers in its static inverters. The project was, until upgrading in 1993, a bipolar HVDC line with an operating voltage of 400 kV and a maximum transmission capacity of 1200 MW.

The transmission line connecting the static inverter stations at Benmore Dam in the South Island and Haywards in the North Island has a total length of 610 km. The line runs overhead for 570 km. A 40-km undersea cable is laid across Cook Strait. In 1993 the system was upgraded with thyristors in its static rectifiers, which use a transfer voltage of 350 kV. During this upgrade the static inverters of the old scheme, which still use the mercury arc valves from 1965, were modified so that they are now switched in parallel.

As of 21 September 2007, part of Pole 1 of the system which still utilized the original mercury arc rectifiers, was shut down 'indefinitely', [ [http://www.gridnewzealand.co.nz/n352.html Transpower stands down HVDC Pole 1] (from the 'gridnewzealand.co.nz' website. Accessed 2007-10-14.)] though in December 2007, Transpower announced that one half of Pole 1 would be returned to 'warm standby' service prior to the 2008 winter, in order to meet North Island demand if required. [" [http://www.transpower.co.nz/?id=6539 Transpower decommissions half of Pole 1] " (Transpower media release, Wednesday 19 December 2007.)] Transpower also noted in November 2007 that by December 2007, it would increase the south to north transfer capacity at Pole 2 from 500MW to 700MW by reconfiguring the three operational undersea cables by switching one of the two undersea Pole 1 cables to Pole 2. [" [http://www.nzherald.co.nz/topic/story.cfm?c_id=187&objectid=10477123 Geothermal plant in Contact's Taupo plan] " - "New Zealand Herald", Tuesday 20 November 2007] .

Transpower announced on 13 March 2008 that the work required to restore half of Pole 1 to service at times of peak North Island demand had been completed, and that this would be available for the winter months. Power transfer would be strictly limited to northwards flow, reducing the stress on the old technology. [" [http://www.transpower.co.nz/?id=1445 Transpower to restore Pole 1] " - "Transpower", Friday 13 March 2008]

References

* ISBN 978-0908893003 White diamonds north: 25 years' operation of the Cook Strait cable, 1965-1990

External links

* [http://www.gridnewzealand.co.nz/n45.html New Zealand's HVDC Link]
* [http://www.abb.com/GLOBAL/GAD/GAD02181.NSF/viewUNID/C1256D71001E0037C125683400270FA6?OpenDocument&v=17EA&e=us New Zealand HVDC - the interisland link] (from the ABB website)


Wikimedia Foundation. 2010.

Игры ⚽ Нужно сделать НИР?

Look at other dictionaries:

  • HGÜ Inter-Island — Landkarte der Hochspannungsleitungen in Neuseeland. Die HGÜ Inter Island ist als punktierte Linie eingezeichnet …   Deutsch Wikipedia

  • Liste des installations de HVDC — Une liste des installations de HVDC dans le monde. Table Notes: B2B = Back to Back HVDC IGBT = Installation à base de transistor bipolaire à grille isolée Thury = A base des générateurs connecté en sérrie suivant les principes de René Thury Merc …   Wikipédia en Français

  • National Grid (New Zealand) — The major transmission network in New Zealand. Generation and load centres are shown as blue and red circles respectively. The major AC transmission corridors are shown as black lines, with the HVDC Inter Island shown as a dashed line. The… …   Wikipedia

  • Submarine power cable — Submarine power cables are cables for electrical power running through the sea, below the surface.A DC system may use the ground and seawater as a return path for current. However, this cannot be always practiced because of disturbances to… …   Wikipedia

  • Cook Strait — …   Wikipedia

  • Mercury arc valve — A mercury arc valve (mercury vapor rectifier) is a type of electrical rectifier which converts alternating current into direct current. Rectifiers of this type were used in electric motor power supplies for industry, in electric… …   Wikipedia

  • Hochspannungs-Gleichstrom-Übertragung — Die Hochspannungs Gleichstrom Übertragung (HGÜ) ist ein Verfahren der elektrischen Energieübertragung mit hoher Gleichspannung von über 100 kV. Der in der Praxis gelegentlich verwendete englische Begriff lautet HVDC (englisch High… …   Deutsch Wikipedia

  • Maraetai Power Station — Maraetai Power Station …   Wikipedia

  • Hayward — was originally Hayward (profession), an officer of a township in charge of fences and enclosures. It may also refer to: Contents 1 People with surname Hayward 2 People with given name Hayward …   Wikipedia

  • Haywards — Location map New Zealand label=Haywards lat dir=S | lat deg=41 | lat min=09 lon dir=E | lon deg=174 | lon min=59 position=left width= 150 float=right caption=Haywards is the location in Wellington, New Zealand where the North Island static… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”