Blower door

Blower door

A blower door is a diagnostic tool designed to measure the airtightness of buildings. and to help locate air leakage sites. A blower door consists of a calibrated fan for measuring an airflow rate, and a pressure-sensing device to measure the air pressure created by the fan flow. The combination of pressure and fan-flow measurements are used to determine the building airtightness. The airtightness of a building is useful knowledge when trying to increase energy conservation or decrease indoor air pollution, or control building pressures.

Uses of blower-door testing

Blower doors can be used in a variety of types of testing. These include (but aren't limited to):
* NFPA Clean Agent Retention testing (this type of testing is usually described as a "door fan test" rather than a blower door test)
* Testing residential houses for air tightness
* Testing buildings for compliance with standards for energy efficiency, such as those by the Leadership in Energy and Environmental Design (LEED) and Passive House/Passivhaus.
* Testing building envelopes and window frames for water tightness and rain penetration

How blower-door tests work

A basic blower-door system includes three components: a calibrated fan, a door-panel system, and a device to measure fan flow and building pressure. The blower-door fan is temporarily sealed into an exterior doorway using the door-panel system. The fan is used to blow air into or out of the building, which creates a small pressure difference between inside and outside. This pressure difference forces air through all holes and penetrations in the building enclosure. The tighter the building (e.g. fewer holes), the less air is needed from the blower door fan to create a change in building pressure.

Blower-door airtightness measurements are presented in a number of different formats, including but not limited to:

Air flow

CFM50 is defined as the air flow (in cubic feet per minute) needed to create a 50-pascal pressure change in the building envelope. CFM50 is one of the most basic measurements of airtightness. Air flow measurements are sometimes referenced to different building pressures such as 25 or 75 pascals.

Air changes per hour at 50 pascals

In order to compare the relative airtightness of buildings, it is useful to normalize the measurements for the size of the building. This allows easy comparison of various sized buildings to each other, or to program guidelines. One of the most common ways to normalize building airtightness is to calculate the number of times per hour that the total volume of the enclosure is changed, when the enclosure is subjected to a 50-pascal pressure difference. To calculate air changes per hour, the total volume of the enclosure is required in addition to the CFM50 measurement. It is also common to use the building enclosure surface area to normalize airtightness measurements.

A pressure of 50 Pa is equal to convert|0.2|in|mm of water column.

Leakage area

Leakage area estimates are a useful way to visualize the cumulative size of all leaks or holes in the building enclosure. Estimated leakage areas can also be used in infiltration models to estimate natural infiltration rates (i.e. the air change rate under natural weather conditions). In order to accurately estimate leakage areas, it is best to conduct the blower-door test over a wide range of building pressures (e.g. 60 Pa to 15 Pa). There are a variety of standard calculation methods used to calculate leakage areas.

Leakage area per square area

Leakage area estimates can also be normalized for the size of the enclosure being tested, For example, the LEED Green Building Rating System has set an airtightness standard for multifamily dwelling units of convert|1.25|sqin|cm2 of leakage area per convert|100|sqft|m2 of enclosure area, in order to control tobacco smoke between units. This is equal to 0.868cm²/m². [ [http://www.us.sbt.siemens.com/siemensleed/EAC9C15D.html Siemens Building Technologies] ]

Manufacturers

There are three main manufacturers of blower doors.

* [http://www.energyconservatory.com/ Energy Conservatory] makers of the Minneapolis Blower Door
* [http://www.infiltec.com/ Infiltec]
* [http://www.retrotec.com/ Retrotec Energy Innovations Ltd.]

References


Wikimedia Foundation. 2010.

Игры ⚽ Поможем сделать НИР

Look at other dictionaries:

  • Blower-Door — eingebautes Blower Door Gerät Mit dem Differenzdruck Messverfahren (auch: Blower Door Test) wird die Luftdichtheit eines Gebäudes gemessen. Das Verfahren dient dazu, Leckagen in der Gebäudehülle aufzuspüren und die Luftwechselrate zu bestimmen.… …   Deutsch Wikipedia

  • Blower Door — eingebautes Blower Door Gerät Mit dem Differenzdruck Messverfahren (auch: Blower Door Test) wird die Luftdichtheit eines Gebäudes gemessen. Das Verfahren dient dazu, Leckagen in der Gebäudehülle aufzuspüren und die Luftwechselrate zu bestimmen.… …   Deutsch Wikipedia

  • Blower Door — zur Messung der Luftdichtheit der Gebäudehülle bedient man sich der Differenzdruckmethode, bei der mit Hilfe einer Blower Door die Luftundichtigkeiten quantifiziert und lokalisiert werden …   Erläuterung wichtiger Begriffe des Bauwesens

  • Blower-Door-Test — eingebautes Blower Door Gerät Mit dem Differenzdruck Messverfahren (auch: Blower Door Test) wird die Luftdichtheit eines Gebäudes gemessen. Das Verfahren dient dazu, Leckagen in der Gebäudehülle aufzuspüren und die Luftwechselrate zu bestimmen.… …   Deutsch Wikipedia

  • Blower door test — Test d infiltrométrie Le test d infiltrométrie (Blower door test) permet de mesurer la quantité d air rentrant dans un bâtiment et où se situent les fuites d air. Grâce à ce test, on peut connaître la quantité d air froid qui entre dans l habitat …   Wikipédia en Français

  • Blower Door —   A device used by energy auditors to pressurize a building to locate places of air leakage and energy loss …   Energy terms

  • Blower-Door-Test — Differenzdruck Messverfahren …   Universal-Lexikon

  • Blow-door-Test — eingebautes Blower Door Gerät Mit dem Differenzdruck Messverfahren (auch: Blower Door Test) wird die Luftdichtheit eines Gebäudes gemessen. Das Verfahren dient dazu, Leckagen in der Gebäudehülle aufzuspüren und die Luftwechselrate zu bestimmen.… …   Deutsch Wikipedia

  • The Whistle Blower — Infobox Film name = The Whistle Blower director = Simon Langton writer =John Hale (book)Julian Bond starring = Michael Caine Barry FosterNigel Havers Gordon Jackson Sir John Gielgud David LangtonJames Fox producer = Geoffrey Reeve distributor =… …   Wikipedia

  • Fan blower — Fan Fan (f[a^]n), n. [AS. fann, fr. L. vannus fan, van for winnowing grain; cf. F. van. Cf. {Van} a winnowing machine, {Winnow}.] 1. An instrument used for producing artificial currents of air, by the wafting or revolving motion of a broad… …   The Collaborative International Dictionary of English

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”