- Flue gas stack
] A flue gas stack is a type of
chimney , a vertical pipe, channel or similar structure through whichcombustion product gases calledflue gas es are exhausted to the outside air. Flue gases are produced whencoal ,oil ,natural gas ,wood or any other fuel is combusted in an industrialfurnace , a power plant's steam-generatingboiler , or other large combustion device. Flue gas is usually composed ofcarbon dioxide (CO2) and water vapor as well asnitrogen and excessoxygen remaining from the intake combustion air. It also contains a small percentage of pollutants such asparticulate matter ,carbon monoxide ,nitrogen oxides andsulfur oxides . The flue gas stacks are often quite tall, up to 400 meters (1300 feet) or more, so as to disperse the exhaust pollutants over a greater area and thereby reduce theconcentration of the pollutants to the levels required by governmental environmental policy and environmental regulation.When the flue gases are exhausted from stoves, ovens, fireplaces, or other small sources within residential abodes, restaurants, hotels, or other public buildings and small commercial enterprises, their flue gas stacks are referred to as chimneys.
History
The first industrial chimneys were built in the mid-17th century when it was first understood how they could improve the combustion of a
furnace by increasing the draft (draught) of air into the combustion zone. [Douet, James (1988). "Going up in Smoke:The History of the Industrial Chimney", Victorian Society, London, England. [http://www.victoriansociety.org.uk/caserpts.html Victorian Society Casework Reports] ] As such, they played an important part in the development ofreverberatory furnace s and a coal-based metallurgical industry, one of the key sectors of the earlyIndustrial Revolution . Most 18th century industrial chimneys (now commonly referred to as flue gas stacks) were built into the walls of the furnace much like a domestic chimney. The first free-standing industrial chimneys were probably those erected at the end of the long condensingflue s associated with smeltinglead .The powerful association between industrial chimneys and the characteristic smoke-filled landscapes of the industrial revolution was due to the universal application of the
steam engine for most manufacturing processes. The chimney is part of a steam-generatingboiler , and its evolution is closely linked to increases in the power of the steam engine. The chimneys ofThomas Newcomen ’s steam engine were incorporated into the walls of the engine house. The taller, free-standing industrial chimneys that appeared in the early 19th century were related to the changes in boiler design associated withJames Watt ’s "double-powered" engines, and they continued to grow in stature throughout the Victorian period. Decorative embellishments are a feature of many industrial chimneys from the 1860s, with over-sailing caps and patterned brickwork.The invention of fan-assisted forced draft (draught) in the early 20th century removed the industrial chimney's original function, that of drawing air into the steam-generating boilers or other furnaces. With the replacement of the steam engine as a prime mover, first by diesel engines and then by electric motors, the early industrial chimneys began to disappear from the industrial landscape. Building materials changed from stone and brick to steel and later reinforced concrete, and the height of the industrial chimney was determined by the need to disperse combustion flue gases to comply with governmental
air pollution control regulations.Flue gas stack draft (or draught)
The combustion flue gases inside the flue gas stacks are much hotter than the ambient outside air and therefore less dense than the ambient air. That causes the bottom of the vertical column of hot flue gas to have a lower
pressure than the pressure at the bottom of a corresponding column of outside air. That higher pressure outside the chimney is the driving force that moves the required combustion air into the combustion zone and also moves the flue gas up and out of the chimney. That movement or flow of combustion air and flue gas is called "natural draft (or draught)", "natural ventilation", "chimney effect", or "stack effect ". The taller the stack, the more draft (or draught) is created.The equation below provides an approximation of the pressure difference, Δ"P", (between the bottom and the top of the flue gas stack) that is created by the draft: [ [http://www.arch.hku.hk/teaching/lectures/airvent/sect02.htm Natural Ventilation Lecture 2] ] [cite book|author=Perry, R.H. and Green, Don W.|title=Perry's Chemical Engineers' Handbook|edition=6th Edition (page 9-72)|publisher=McGraw-Hill Book Company|year=1984|id=ISBN 0-07-049479-7]
:
:
The above equation is an approximation because it assumes that the
molar mass of the flue gas and the outside air are equal and that the pressure drop through the flue gas stack is quite small. Both assumptions are fairly good but not exactly accurate.The flue gas flow rate induced by the draft
As a "first guess" approximation, the following equation can be used to estimate the flue gas flow rate induced by the draft of a flue gas stack. The equation assumes that the molar mass of the flue gas and the outside air are equal and that the frictional resistance and heat losses are negligible: [ [http://www.arch.hku.hk/teaching/lectures/airvent/sect03.htm Natural Ventilation Lecture 3] ]
:
Designing chimneys and stacks to provide the correct amount of natural draft involves a great many factors such as:
* The height and diameter of the stack.
* The desired amount of excess combustion air needed to assure complete combustion.
* The temperature of the flue gases leaving the combustion zone.
* The composition of the combustion flue gas, which determines the flue gasdensity .
* The frictional resistance to the flow of the flue gases through the chimney or stack, which will vary with the materials used to construct the chimney or stack.
* The heat loss from the flue gases as they flow through the chimney or stack.
* The local atmospheric pressure of the ambient air, which is determined by the local elevation above sea level.The calculation of many of the above design factors requires trial-and-error reiterative methods.
Governmental agencies in most countries have specific codes which govern how such design calculations must be performed. Many non-governmental organizations also have codes governing the design of chimneys and stacks (notably, the ASME codes).
Other items of interest
It should be noted that not all fuel-burning industrial equipment relies upon natural draft. Many such equipment items use large fans or blowers to accomplish the same objectives, namely: the flow of combustion air into the combustion chamber and the flow of the hot flue gas out of the chimney or stack.
A great many power plants are equipped with facilities for the removal of
sulfur dioxide (i.e.,flue gas desulfurization ),nitrogen oxides (i.e,selective catalytic reduction ,exhaust gas recirculation , thermal deNOx, or low NOx burners) andparticulate matter (i.e.,electrostatic precipitator )s. At such power plants, it is possible to use acooling tower as a flue gas stack. Examples can be seen in Germany at thePower Station Staudinger Grosskrotzenburg and at theRostock Power Station . Power plants without flue gas purification, would experience serious corrosion in such stacks.In the United States and a number of other countries,
atmospheric dispersion modeling [cite book|author=Beychok, Milton R.|title=Fundamentals Of Stack Gas Dispersion |edition=4th Edition|publisher=author-published|year=2005|id=ISBN 0-9644588-0-2 [http://www.air-dispersion.com www.air-dispersion.com] ] studies are required to determine the flue gas stack height needed to comply with the localair pollution regulations. The United States also limits the maximum height of a flue gas stack to what is known as the "Good Engineering Practice (GEP)" stack height. ["Guideline for Determination of Good Engineering Practice Stack Height (Technical Support Document for the Stack Height Regulations), Revised" (1985), EPA Publication No. EPA–450/4–80–023R, U.S. Environmental Protection Agency (NTIS No. PB 85–225241)] [Lawson, Jr., R.E. and W.H. Snyder (1983). "Determination of Good Engineering Practice Stack Height: A Demonstration Study for a Power Plant", EPA Publication No. EPA–600/3–83–024. U.S. Environmental Protection Agency (NTIS No. PB 83–207407)] In the case of existing flue gas stacks that exceed the GEP stack height, any air pollution dispersion modeling studies for such stacks must use the GEP stack height rather than the actual stack height.ee also
*
Chimney
*Flue gas
*Flue gas desulfurization
*Flue gas emissions from fossil fuel combustion
*Incineration
*Stack effect References
External links
* [http://www.ashrae.org/publications/page/158 ASHRAE's Fundamentals Handbook] is available here from
ASHRAE
* [http://www.asme.org/Codes/ ASME Codes and Standards] available fromASME
* [http://www.skyscraperpage.com/diagrams/?20374745 Diagram of 25 tallest flue gas stacks worldwide]
Wikimedia Foundation. 2010.