DCB (Digital Control Bus, Digital Connection Bus[1] or Digital Communication Bus[2][3] in some sources) was a proprietary data interchange interface by Roland Corporation, developed in 1981[3] and introduced in 1982 in their Roland Juno-60 and Roland Jupiter-8 products[3]. DCB functions were basically the same as MIDI, but unlike MIDI (which is capable of transmitting a wide array of information), DCB could provide note on/off and program change only. Data was relayed using a thick cable that connected to a port vaguely resembling a parallel port. DCB-to-MIDI adapters were produced for a number of early Roland products. The DCB interface was made in 2 variants, earlier one used 14-pin sockets and cables, later switching to standard DIN 5-pin plugs — connectors that became MIDI standard[3].

Contents

Supporting equipment

DCB was quickly replaced by MIDI in the early 1980s. The only DCB-equipped instruments produced were the Roland Jupiter-8 and Juno-60[2]; Roland produced at least two DCB sequencers, the JSQ-60 and the MSQ-700. The latter was capable of saving eight sequences, or a total of 3000 notes, and was capable of transmitting and receiving data via MIDI (though it could not convert signals between DCB and MIDI, nor could it use both protocols simultaneously). Roland later released the MD-8, a rather large black box capable of converting MIDI signals to DCB and vice versa. While this allows note on/off to be sent to a Juno-60 by MIDI, the solution pales in comparison to the full MIDI implementation on the Juno-60's successor, the Roland Juno-106. A few companies offer similar conversion boxes to connect DCB instruments to regular MIDI systems for support of vintage synths in modern sound production environments.

Implementation

Following information comes from the Roland Juno 60 Service Notes, First Edition, page 17-19.

Physical connection

DCB uses a special 14-wire connection. The first 7 consist of 3 wires in each direction plus a shared ground. The signals are standard TTL 0-5V, except the Rx Busy output, which is an open collector pulldown.

1. Rx Busy 2. Rx Data 3. Rx Clock 4. Ground 5. Tx Busy 6. Tx Data 7. Tx Clock

The remaining 7 wires may be used for special purposes.

8. Unreg 9. VCA Lower 10. VCA Upper 11. VCF Lower 12. VCF upper 13. VCO-2 14. VCO-1

These are not used in the Juno 60.

Pinout

View from rear panel. Amphenol DDK connector.

7  6  5  4  3  2  1 

14 13 12 11 10 9 8

Serial data

The DCB is a standard asynchronous serial stream (using an 8251A IC in the Juno 60), LSB first, 8 data bits, 2 stop bits, odd parity, and a Baud rate of 31.25kHz.

Message (Block) Structure)

DCB data is sent in short blocks messages consisting of an identifier, one or more data codes, and an end mark. Blocks may be sent intermittently (JP-8, OP-8) or continuously (Juno 60), in which case end marks are not used.

Identifier/start Data Data ... End
F1-FE 0-F0 0-F0 ... FF

Identifier is 1 byte using a value F1 through FE, which acts as both a start marker and a message type. Data which follows must not use these data bytes. In practice only FD (patch code) and FE (key code) are used.

Data codes are one or more sections or channels, each one byte. The number of bytes or channels depends on the transmitter's configuration, but doesn't change once communication has been started. All data values must be in the range 00-F0.

The end mark is an FF character. It is omitted if the message has a predefined length or the next message starts immediately after the data.

FD: Patch Code Block

This message identifies a patch, by a single byte. Juno 60 ignores this. It is sent once after a patch change, with the first key code by OP-8 and JP-8. It does not have an end mark.

FE: Key Code

This message identifies a key event. It contains one byte for each note channel the transmitter supports - so it is 8 bytes long for JP-8 and OP-8, or 6 bytes for Juno 60. Each channel byte defines a key number (bits 0-6) and whether the key is gated on (1) or off (bit 7). Keys are identified with 0-96 with zero meaning C0 (16.4Hz), up to 96 C8 (4205Hz). Channels are assigned in the order defined by the transmitter's key assign mode. For OP-8, this is Ch1 - Ch8. For JP-8 split mode, Upper 4 keys followed by Lower 4 keys. JP-8 dual mode, the data for the first 4 channels is duplicated to the second 4.

If the Juno-60 receives more channels than it physically has voices, the extra channels are "queued" and played later when possible. Whereas the JP-8 only acccepts 8 channels.