Electrocorticography

Electrocorticography

Electrocorticography (ECoG) is the practice of using electrodes placed directly on the exposed surface of the brain to record electrical activity from the cerebral cortex. ECoG may be performed either in the operating room during surgery (intraoperative ECoG) or outside of surgery (extraoperative ECoG). Because a craniotomy (a surgical incision into the skull) is required to implant the electrode grid, ECoG is an invasive procedure. ECoG is currently considered to be the “gold standard” for defining epileptogenic zones in clinical practice.

History

ECoG was pioneered in the early 1950’s by Wilder Penfield and Herbert Jasper, neurosurgeons at the Montreal Neurological Institute. cite journal | author = Andre Palmini| year = 2006 | title = The concept of the epileptogenic zone: a modern look at Penfield and Jasper’s views on the role of interictal spikes | journal = Epileptic Disorders| volume = 8(Suppl 2) | pages = S10–15| id = | url = ] The two developed ECoG as part of their groundbreaking Montreal procedure, a surgical protocol used to treat patients with severe epilepsy. The cortical potentials recorded by ECoG were used to identify epileptogenic zones – regions of the cortex that generate epileptic seizures. These zones would then be surgically removed from the cortex during resectioning, thus destroying the brain tissue where epileptic seizures had originated. Penfield and Jasper also used electrical stimulation during ECoG recordings in patients undergoing epilepsy surgery under local anesthesia. cite journal | author = A. Kuruvilla, R. Flink | year = 2003 | title = Intraoperative electrocorticography in epilepsy surgery: useful or not? | journal = Seizure | volume =12 | pages = 577–584 | id = | url = | doi = 10.1016/S1059-1311(03)00095-5 ] This procedure was used to explore the functional anatomy of the brain, mapping speech areas and identifying the somatosensory and somatomotor cortex areas to be excluded from surgical removal.

Electrophysiological Basis

ECoG signals are composed of synchronized postsynaptic potentials (local field potentials), recorded directly from the exposed surface of the cortex. The potentials occur primarily in cortical pyramidal cells, and thus must be conducted through several layers of the cerebral cortex, cerebrospinal fluid (CSF), pia mater, and arachnoid mater before reaching subdural recording electrodes placed just below the dura mater (outer cranial membrane). However, to reach the scalp electrodes of an electroencephalogram (EEG), electrical signals must also be conducted through the skull, where potentials rapidly attenuate due to the low conductivity of bone. For this reason, the spatial resolution of ECoG is much higher than EEG, a critical imaging advantage for presurgical planning. cite journal | author = Kimiaki Hashiguchi, Takato Morioka, Fumiaki Yoshida, Yasushi Miyagi, Shinji Nagata, Ayumi Sakata, Tomio Sasaki | year = 2007 | title = Correlation between scalp-recorded electroencephalographic and electrocorticographic activities during ictal period | journal = Seizure | volume = 16 | pages = 238–247| id = | url = | doi = 10.1016/j.seizure.2006.12.010 ] ECoG offers a temporal resolution of approximately 5 ms and a spatial resolution of 1 cm. cite journal | author = Eishi Asano, Csaba Juhasz, Aashit Shah, Otto Muzik, Diane C. Chugani, Jagdish Shad, Sandeep Sood, Harry T. Chugani| year = 2005 | title = Origin and Propagation of Epileptic Spasms Delineated on Electrocorticography | journal = Epilepsia| volume =46 | pages = 1086–1097| id = | url = | doi = 10.1111/j.1528-1167.2005.05205.x ]

Using depth electrodes, the local field potential gives a measure of a neural population in a sphere with a radius of 0.5-3 mm around the tip of the electrode. cite journal | author = Nikos K. Logothetis| year = 2003 | title = The underpinning of the Bold functional magnetic resonance imaging signal | journal = Journal of Neuroscience| volume =23 | pages = 3963–3971| id = | url = ] With a sufficiently high sampling rate (more than about 10 kHz), depth electrodes can also measure action potentials. cite journal | author = Istvan Ulbert, Eric Halgren, Gary Heit, George Karmos| year = 2001 | title = Multiple microelectrode-recording system for human intracortical applications | journal = Journal of Neuroscience Methods | volume =106 | pages = 69–79| id = | url = | doi = 10.1016/S0165-0270(01)00330-2 ] In which case the temporal resolution is down to individual neurons, and the field of view of an individual electrode is approximately 0.05-0.35 mm. cite journal | author = Nikos K. Logothetis| year = 2003 | title = the Underpinning of the Bold Functional Magnetic resonance imaging Signal | journal = The Journal of Neuroscience| volume =23 | pages = 3963–3971| id = | url = ]

Procedure

The ECoG recording is performed from electrodes placed on the exposed cortex. In order to access the cortex, a surgeon must first perform a craniotomy, removing a part of the skull to expose the brain surface. This procedure may be performed either under general anesthesia or under local anesthesia if patient interaction is required for functional cortical mapping. Electrodes are then surgically implanted on the surface of the cortex, with placement guided by the results of preoperative EEG and magnetic resonance imaging (MRI). Electrodes may either be placed outside the dura mater (epidural) or under the dura mater (subdural). ECoG electrode arrays typically consist of sixteen sterile, disposable stainless steel, carbon tip, platinum, or gold ball electrodes, each mounted on a ball and socket joint for ease in positioning. These electrodes are attached to an overlying frame in a “crown” or “halo” configuration. cite journal | author = L. Schuh, I. Drury | year = 1996 | title = Intraoperative Electrocorticography and Direct Cortical Electrical Stimulation | journal = Seminars in Anesthesia| volume =16 | pages = 46–55| id = | url = ] Subdural strip and grid electrodes are also widely used in various dimensions, having anywhere from 4 to 64 electrode contacts. The grids are transparent, flexible, and numbered at each electrode contact. Standard spacing between grid electrodes is 1 cm; individual electrodes are typically 5mm in diameter. The electrodes sit lightly on the cortical surface, and are designed with enough flexibility to ensure that normal movements of the brain do not cause injury. A key advantage of strip and grid electrode arrays is that they may be slid underneath the dura mater into cortical regions not exposed by the craniotomy. Strip electrodes and crown arrays may be used in any combination desired. Depth electrodes may also be used to record activity from deeper structures such as the hippocampus.

DCES

Direct cortical electrical stimulation (DCES) is frequently performed in concurrence with ECoG recording for functional mapping of the cortex and identification of critical cortical structures.cite journal | author = L. Schuh, I. Drury | year = 1996 | title = Intraoperative Electrocorticography and Direct Cortical Electrical Stimulation | journal = Seminars in Anesthesia| volume =16 | pages = 46–55| id = | url = ] When using a crown configuration, a handheld wand bipolar stimulator may be used at any location along the electrode array. However, when using a subdural strip, stimulation must be applied between pairs of adjacent electrodes due to the nonconductive material connecting the electrodes on the grid. Electrical stimulating currents applied to the cortex are relatively low, between 2 to 4 mA for somatosensory stimulation, and near 15 mA for cognitive stimulation. cite journal | author = L. Schuh, I. Drury | year = 1996 | title = Intraoperative Electrocorticography and Direct Cortical Electrical Stimulation | journal = Seminars in Anesthesia| volume =16 | pages = 46–55| id = | url = ] The functions most commonly mapped through DCES are primary motor, primary sensory, and language. The patient must be alert and interactive for mapping procedures, though patient involvement varies with each mapping procedure. Language mapping may involve naming, reading aloud, repetition, and oral comprehension; somatosensory mapping requires that the patient describe sensations experienced across the face and extremities as the surgeon stimulates different cortical regions. cite journal | author = L. Schuh, I. Drury | year = 1996 | title = Intraoperative Electrocorticography and Direct Cortical Electrical Stimulation | journal = Seminars in Anesthesia| volume =16 | pages = 46–55| id = | url = ]

Clinical Applications

Since its development in the 1950’s, ECoG has been used to localize epileptogenic zones during presurgical planning, map out cortical functions, and to predict the success of epileptic surgical resectioning. ECoG offers several advantages over alternative diagnostic modalities:

* Flexible placement of recording and stimulating electrodes cite journal | author = A. Kuruvilla, R. Flink | year = 2003 | title = Intraoperative electrocorticography in epilepsy surgery: useful or not? | journal = Seizure | volume =12 | pages = 577–584 | id = | url = | doi = 10.1016/S1059-1311(03)00095-5 ]

* Can be performed at any stage before, during, and after a surgery
* Allows for direct electrical stimulation of the brain, identifying critical regions of the cortex to be avoided during surgery
* Greater precision and sensitivity than an EEG scalp recording - spatial resolution is higher and signal-to-noise ratio is superior due to greater proximity to neural activity

Limitations of ECoG include:

* Limited sampling time – seizures (ictal events) may not be recorded during the ECoG recording period
* Limited field of view – electrode placement is limited by the area of exposed cortex and surgery time, sampling errors may occur
* Recording is subject to the influence of anesthetics, narcotic analgesics, and the surgery itself cite journal | author = A. Kuruvilla, R. Flink | year = 2003 | title = Intraoperative electrocorticography in epilepsy surgery: useful or not? | journal = Seizure | volume =12 | pages = 577–584 | id = | url = | doi = 10.1016/S1059-1311(03)00095-5 ]

Intractable Epilepsy

Epilepsy is currently ranked as the third most commonly diagnosed neurological disorder, afflicting approximately 2.5 million people in the United States alone. cite journal | author = Michael Kohrman | year = 2007 | title = What is Epilepsy? Clinical Perspectives in the Diagnosis and Treatment | journal = Journal of Clinical Neurophysiology | volume = 24 | pages = 87–95| id = | url = | doi = 10.1097/WNP.0b013e3180415b51 ] Epileptic seizures are chronic and unrelated to any immediately treatable causes, such as toxins or infectious diseases, and may vary widely based on etiology, clinical symptoms, and site of origin within the brain. For patients with intractable epilepsy – epilepsy that is unresponsive to anticonvulsants – surgical treatment may be a viable treatment option.

Extraoperative ECoG

Before a patient can be identified as a candidate for resectioning surgery, MRI must be performed to demonstrate the presence of a structural lesion within the cortex, supported by EEG evidence of epileptogenic tissue. cite journal | author = A. Kuruvilla, R. Flink | year = 2003 | title = Intraoperative electrocorticography in epilepsy surgery: useful or not? | journal = Seizure | volume =12 | pages = 577–584 | id = | url = | doi = 10.1016/S1059-1311(03)00095-5 ] Once a lesion has been identified, ECoG may be performed to determine the location and extent of the legion and surrounding irritative region. The scalp EEG, while a valuable diagnostic tool, lacks the precision necessary to localize the epileptogenic region. ECoG is considered to be the gold standard for assessing neuronal activity in patients with epilepsy, and is widely used for presurgical planning to guide surgical resection of the lesion and epileptogenic zone. cite journal | author = Hidenori Sugano, Hiroyuki Shimizu, Shigeki Sunaga | year = 2007 | title = Efficacy of intraoperative electrocorticography for assessing seizure outcomes in intractable epilepsy patients with temporal-lobe-mass lesions. | journal = Seizure| volume = 16 | pages = 120–127 | id = | url = | doi = 10.1016/j.seizure.2006.10.010 ] , cite journal | author = Kai J. Miller, Marcel denNijs, Pradeep Shenoy, John W. Miller, Rajesh P.N. Rao, Jeffrey G. Ojemann| year = 2007 | title = Real-time functional brain mapping using electrocorticography | journal = NeuroImage| volume = 37| pages = 504–507| id = | url = | doi = 10.1016/j.neuroimage.2007.05.029 ] The success of the surgery depends on accurate localization and removal of the epileptogenic zone. ECoG data is assessed with regard to ictal spike activity – “diffuse fast wave activity” recorded during a seizure – and interictal epileptiform activity (IEA), brief bursts of neuronal activity recorded between epileptic events. ECoG is also performed following the resectioning surgery to detect any remaining epileptiform activity, and to determine the success of the surgery. Residual spikes on the ECoG, unaltered by the resection, indicate poor seizure control, and incomplete neutralization of the epileptogenic cortical zone. Additional surgery may be necessary to completely eradicate seizure activity.

Intraoperative ECoG

The objective of the resectioning surgery is to remove the epileptogenic tissue without causing unacceptable neurological consequences. In addition to identifying and localizing the extent of epileptogenic zones, ECoG used in conjunction with DCES is also a valuable tool for functional cortical mapping. It is vital to precisely localize critical brain structures, identifying which regions the surgeon must spare during resectioning (the “eloquent cortex”) in order to preserve sensory processing, motor coordination, and speech. Functional mapping requires that the patient be able to interact with the surgeon, and thus is performed under local rather than general anesthesia. Electrical stimulation using cortical and acute depth electrodes is used to probe distinct regions of the cortex in order to identify centers of speech, somatosensory integration, and somatomotor processing. During the resectioning surgery, intraoperative ECoG may also be performed to monitor the epileptic activity of the tissue and ensure that the entire epileptogenic zone is resectioned. Although the use of extraoperative and intraoperative ECoG in resectioning surgery has been an accepted clinical practice for several decades, recent studies have shown that the usefulness of this technique may very based on the type of epilepsy a patient exhibits. Kuruvilla and Flink reported that while intraoperative ECoG plays a critical role in tailored temporal lobectomies, in multiple subpial transections (MST), and in the removal of malformations of cortical development (MCDs), it has been found impractical in standard resection of medial temporal lobe epilepsy (TLE) with MRI evidence of mesial temporal sclerosis (MTS). cite journal | author = A. Kuruvilla, R. Flink | year = 2003 | title = Intraoperative electrocorticography in epilepsy surgery: useful or not? | journal = Seizure | volume =12 | pages = 577–584 | id = | url = | doi = 10.1016/S1059-1311(03)00095-5 ] A study performed by Wennberg, Quesney, and Rasmussen demonstrated the presurgical significance of ECoG in frontal lobe epilepsy (FLE) cases. cite journal | author = R. Wennberg, F. Quesney, A. Olivier, T. Rasmussen| year = 1998 | title = Electrocorticography and outcome in frontal lobe epilepsy | journal = Electroencephalography and Clinical Neurophysiology | volume =106 | pages = 357–368 | id = | url = | doi = 10.1016/S0013-4694(97)00148-X ]

Research Applications

ECoG has recently emerged as a promising recording technique for use in brain-computer interfaces (BCI). cite journal | author = Pradeep Shenoy, Kai J. Miller, Jeffrey G. Ojemann, Rajesh P.N. Rao| year = 2007 | title = Generalized Features for Electrocorticographic BCIs | journal = | volume = | pages = | id = | url = http://www.cs.washington.edu/homes/pshenoy/papers/ecogclassif_tbme07preprint.pdf ] BCIs are direct neural interfaces that provide control of prosthetic, electronic, or communication devices via direct use of the individual’s brain signals. Brain signals may be recorded either invasively, with recording devices implanted directly into the cortex, or noninvasively, using EEG scalp electrodes. ECoG serves to provide a partially invasive compromise between the two modalities – while ECoG does not penetrate the blood-brain barrier like invasive recording devices, it features a higher spatial resolution and higher signal-to-noise ratio than EEG. A recent study by Shenoy et al demonstrates the high movement classification accuracy potential of ECoG-based BCIs.

Recent Advances in ECoG technology

The electrocorticogram is still considered to be the “gold” standard for defining epileptogenic zones; however, this procedure is risky and highly invasive. Recent studies have explored the development of a noninvasive cortical imaging technique for presurgical planning that can provide the same information and resolution of the invasive ECoG.

In one novel approach, Bin He et al cite journal | author = Lei Ding, Christopher Wilke, Bobby Xu, Xiaoliang Xu, Wim van Drongelen, Michael Kohrman, Bin He | year = 2007 | title = EEG source imaging: correlating source locations and extents with electrocorticography and surgical resections in epilepsy patients | journal = Journal of Clinical Neurophysiology | volume = 24 | pages = 130–136| id = | url = | doi = 10.1097/WNP.0b013e318038fd52 ] seek to integrate the information provided by a structural MRI and scalp EEG to provide a noninvasive alternative to ECoG. This study investigated a high-resolution subspace source localization approach, FINE (first principle vectors) to image the locations and estimate the extents of current sources from the scalp EEG. A thresholding technique was applied to the resulting tomography of subspace correlation values in order to identify epileptogenic sources. This method was tested in three pediatric patients with intractable epilepsy, with encouraging clinical results. Each patient was evaluated using structural MRI, long-term video EEG monitoring with scalp electrodes, and subsequently with subdural electrodes. The ECoG data was then recorded from implanted subdural electrode grids placed directly on the surface of the cortex. MRI and computed tomography images were also obtained for each subject.

The epileptogenic zones identified from preoperative EEG data were validated by observations from postoperative ECoG data in all three patients. These preliminary results suggest that it is possible to direct surgical planning and locate epileptogenic zones noninvasively using the described imaging and integrating methods. EEG findings were further validated by the surgical outcomes of all three patients. After surgical resectioning, two patients are seizure-free and the third has experienced a significant reduction in seizures. Due to its clinical success, FINE offers a promising alternative to preoperative ECoG, providing information about both the location and extent of epileptogenic sources through a noninvasive imaging procedure.

References

See also

* Wilder Penfield
* Herbert Jasper
* epilepsy
* electroencephalogram
* Magnetic Resonance Imaging
* BCI
* FINE - first principle vectors (combination of EEG and MRI for non-invasive alternative to intracranial EEG (icEEG))

External links

* [http://mednews.wustl.edu/news/page/normal/7800.html Teenager moves video icons just by using mind electrocorticographic activity] .


Wikimedia Foundation. 2010.

Игры ⚽ Поможем решить контрольную работу

Look at other dictionaries:

  • electrocorticography — /i lek troh kawr ti kog reuh fee/, n. Med. a technique for surveying the electrical activity of the cerebral cortex by means of an electroencephalograph and electrodes attached to the brain. [ELECTRO + CORTICO + GRAPHY] * * * …   Universalium

  • electrocorticography — noun A form of electroencephalography in which the electrodes are placed directly on the cerebral cortex …   Wiktionary

  • electrocorticography — The technique of recording the electrical activity of the cerebral cortex by means of electrodes placed directly on it. * * * elec·tro·cor·ti·cog·ra·phy .kȯrt i käg rə fē n, pl phies the process of recording electrical activity in the brain by… …   Medical dictionary

  • electrocorticography — elec·tro·cor·ti·cog·ra·phy …   English syllables

  • electrocorticography — …   Useful english dictionary

  • Electroencephalography — (EEG) is the measurement of electrical activity produced by the brain as recorded from electrodes placed on the scalp.Just as the activity in a computer can be understood on multiple levels, from the activity of individual transistors to the… …   Wikipedia

  • Brain-computer interface — A brain computer interface (BCI), sometimes called a direct neural interface or a brain machine interface, is a direct communication pathway between a human or animal brain (or brain cell culture) and an external device. In one way BCIs,… …   Wikipedia

  • Intracranial EEG — (I EEG), sometimes called a sub dural EEG (SD EEG), is where the electrodes for an electroencephalograph (EEG) are placed near the surface of the brain. [ [http://www.aboutkidshealth.ca/Epilepsy/Intracranial EEG.aspx?articleID=7016 categoryID=EP… …   Wikipedia

  • Brain–computer interface — Neuropsychology Topics Brain computer interface …   Wikipedia

  • Cortex — (Latin: bark , rind , shell or husk ) may refer to: Contents 1 Sciences 2 Anatomy 2.1 Organs 2.1.1 The brain 3 …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above