Voltage reduction

Voltage reduction

In a simple resistive circuit, a reduction in the voltage across the resistance will result in a reduction in the power dissipated by the circuit.

Electric Utilities

Electric utilities have discovered that this basic principle can save utility companies, and their customers, a significant amount of money. Utilities are able to shave the peak of their power demand curves by reducing the voltage across their distribution system. When a utility reaches a point where power demand is expected to exceed supply, utilities only have two options. Either purchase power from another utility, usually at substantial prices, or reduce demand. Often utilities use load management systems to turn off customers' air conditioners, water heaters and pool pumps to reduce demand. Voltage reduction has become another option for utilities to reduce demand - typically unbeknownst to the customer. However, only the resistive portion of the load responds to the reduction in voltage to reduce aggregate demand. Loads such as incandescent lights and heater coils will use less power as the voltage is lowered. On the other hand, induction motor loads are unaffected by the reduction in voltage, because the current simply rises to account for no change or even a slight increase in power consumption.

Even some resistive loads provide only short-term benefits. A phenomenon known as load diversity plays a role in voltage reduction and can counteract its effects on occasion. The concept of load diversity can most easily be explained with an example. In your neighborhood, it is unlikely that all of the homes' water heaters are on at the same time. Particularly during non-hot water usage hours (morning and evening showers), when your hot water heater is on, your neighbor's may be off. Due to the distributed and noncoincident nature of these loads, the aggregate peak can remain relatively constant. However, if the voltage is reduced to all of the resistive elements in the water heaters, the elements will not be able to heat the water as quickly. While an immediate reduction in the power demand will be recognized upon initating voltage reduction, over time water heaters will need to be on longer to achieve the thermostat-set water temperature. Thus, more water heaters will be on at the same time. This will cause the aggregate peak to increase substantially. Therefore, with respect to thermostat controlled resitive loads the benefits of voltage reduction can be short lived, and may occasionally end up increasing the aggregate load demand.

The keen eye may also realize that by increasing the voltage, power demand from the resitive loads may increase as well. Again, the thermostat controlled resistive loads will react differently, but it is clear that it will cost a customer more to turn on that incandescent reading lamp with higher voltage than it would at a lower voltage.


Wikimedia Foundation. 2010.

Игры ⚽ Нужна курсовая?

Look at other dictionaries:

  • Voltage reduction —   Any intentional reduction of system voltage by 3 percent or greater for reasons of maintaining the continuity of service of the bulk electric power supply system.   U.S. Dept. of Energy, Energy Information Administration s Energy Glossary …   Energy terms

  • Voltage drop — is the reduction in voltage in an electrical circuit between the source and load. In electrical wiring national and local electrical codes may set guidelines for maximum voltage drop allowed in a circuit, to ensure reasonable efficiency of… …   Wikipedia

  • Reduction potential — (also known as redox potential, oxidation / reduction potential, ORP or Eh) is a measure of the tendency of a chemical species to acquire electrons and thereby be reduced. Reduction potential is measured in volts (V), or millivolts (mV). Each… …   Wikipedia

  • Voltage regulator — A popular three pin 12 V DC voltage regulator IC. A voltage regulator is an electrical regulator designed to automatically maintain a constant voltage level. A voltage regulator may be a simple feed forward design or may include negative feedback …   Wikipedia

  • Réduction électrolytique de l'aluminium — Production de l aluminium par électrolyse La réduction électrolytique de l aluminium est le procédé qui permet de fabriquer le métal aluminium à partir de l alumine extraite de la bauxite. Le procédé a été inventé simultanément par Paul Héroult… …   Wikipédia en Français

  • oxidation–reduction reaction — ▪ chemical reaction Introduction also called  redox reaction        any chemical reaction in which the oxidation number of a participating chemical species changes. The term covers a large and diverse body of processes. Many oxidation– reduction… …   Universalium

  • Dynamic voltage scaling — is a power management technique in computer architecture, where the voltage used in a component is increased or decreased, depending upon circumstances. Dynamic voltage scaling to increase voltage is known as overvolting; dynamic voltage scaling… …   Wikipedia

  • Orders of magnitude (voltage) — To help compare different orders of magnitude, the following list describes various voltage levels. Factor (volt) Value Item 10−7 0.5 μV Change in nerve cell potential caused by opening a single acetylcholine receptor channel[1] 10−6 2 μV Noise… …   Wikipedia

  • Noise reduction — For sound proofing, see soundproofing. For scientific aspects of noise reduction of machinery and products, see noise control. Noise reduction is the process of removing noise from a signal. All recording devices, both analogue or digital, have… …   Wikipedia

  • CPU core voltage — The CPU core voltage (VCORE) is the power supply voltage supplied to the CPU (which is a digital circuit), GPU, or other device containing a processing core. The amount of power a CPU uses, and thus the amount of heat it dissipates, is the… …   Wikipedia

Share the article and excerpts