- Relative humidity
Relative humidity is a measurement of the amount of
water vapor that exists in a gaseous mixture of air and water.Estimating relative humidity
The relative humidity of an air-water vapor mixture can be estimated if both the
temperature ("T") and thedew point temperature ("Td") of the mixture are known. When both "T" and "Td" are expressed in degreescelsius then [ Perry, R.H. and Green, D.W,Perry's Chemical Engineers' Handbook (7th Edition),McGraw-Hill , ISBN 0-07-049841-5 , Page 12-7 ] ::::
where the partial pressure of water vapor in the mixture is estimated by :
:::
and the saturated
vapor pressure of water at the temperature of the mixture is estimated by ::::
In practice both "T" and "Td" are readily estimated by using a sling
psychrometer and the relative humidity of the atmosphere can be calculatedA common misconception
Often the notion of air holding water vapor is used to describe the concept of relative humidity. Relative humidity is wholly understood in terms of the physical properties of water alone and therefore is unrelated to this concept. [http://www.atmos.umd.edu/~stevenb/vapor/] [http://www.ems.psu.edu/~fraser/Bad/BadFAQ/BadCloudsFAQ.html] This is reflected in the definition of relative humidity; only the physical properties of water are considered when determining the relative humidity of an air water mixture.
Air simply acts as a transporter of water vapour not a holder of it. In fact, water vapor can be present in an airless volume and therefore the relative humidity of this volume can be readily calculated.The misconception that air holds water is likely the result of the use of the word "saturation" which is often misused in descriptions of relative humidity. In the present context the word "saturation" refers to the state of water vapor, [http://hyperphysics.phy-astr.gsu.edu/hbase/hframe.html] not the
solubility of one material in another.The thermophysical properties of water-air mixtures encountered at atmospheric conditions are reasonably approximated by assuming they behave as a mixture of
ideal gas es. [http://www.nyu.edu/classes/tuckerman/honors.chem/lectures/lecture_8/node7.html ] For many practical purposes the assumption that both components (air and water) behave independently of each other is reasonable. Therefore the physical properties of an air-water mixture can be estimated by considering the physical properties of each component separately.Significance of relative humidity
Climate control
Climate control refers to the control of temperature and relative humidity for human comfort, health and safety, and for the technical requirements of machines and processes, in buildings, vehicles and other enclosed spaces.
Comfort
Humans are sensitive to humidity because the human body uses evaporative cooling as the primary mechanism to regulate temperature. Under humid conditions the rate that perspiration evaporates from the skin is lower than it would be under arid conditions. Because humans perceive the "rate of heat transfer" from the body rather than temperature itself we feel warmer when the relative humidity is high than when it is low.
For example, if the air temperature is 24 °C (75 °F) and the relative humidity is zero percent then the air temperature feels like 21 °C (69 °F). At the same air temperature if the relative humidity is 100 percent then we feel like it is 27 °C (80 °F). In other words, at a temperature of 24 °C air is saturated with water vapor and the human body cools itself at the same rate as it would if it were 27 °C and with no moisture in the air. The
humidex is a measurement that reflects the combined effect of temperature and humidity on cooling of the atmosphere.Moisture Detection
Relative humidity is also used to measure the
moisture in materials such asconcrete . These tests have been shown more accurate than MVER (CaCl) tests. [ [http://www.wwwagner.com/rh_mver_test_chart.php Paired MVER and RH measurements] ]Buildings
When controlling the climate in buldings using
HVAC systems the key is to control the relative humidity in a comfortable range - low enough to be comfortable but high enough to avoid problems associated with very dry air.When the temperature is high and the relative humidity is low evaporation of water is rapid; soil dries, wet clothes hanging outdoors dry quickly, and perspiration readily evaporates from the skin. Wooden furniture can shrink causing the paint that covers these surfaces to fracture.
When the temperature is high and the relative humidity is high evaporation of water is slow. When relative humidity approaches 100 percent condensation can occur on surfaces leading to problems with mold, corrosion, decay, and other moisture-related deterioration.
Certain production and technical processes and treatments in factories, laboratories, hospitals and other facilities require specific relative humidity levels to be maintained using
humidifier s,dehumidifier s and associated control systems.Vehicles
The same basic principles as in buildings, above, apply. In addition there may be safety considerations. For instance high humidity inside a
vehicle can lead to problems of condensation, such as misting ofwindshield s and shorting of electrical components.In sealed vehicles and
pressure vessel s such as pressurisedairliner s,submersible s andspacecraft these considerations may be critical to safety, and complexenvironmental control system s including equipment to maintainpressure are needed. For example, airlinerfuselage s are susceptible to corrosion from humidity, andavionics are susceptible to condensation, and as the failure of either is potentially catastrophic, airliners operate with low internal relative humidity, often under 10%, especially on long flights. The low humidity is a consequence of drawing in the very dry air, often 5% relative humidity or below, which is found at airliner cruising altitudes. This causes discomfort such as sore eyes, dry skin, and drying out ofmucosa , but humidifiers are not employed to raise it to comfortable mid-range levels because essentially dry air in an airliner is safe air.Related concepts
The term relative humidity is reserved for systems of water vapor in air. The term "relative saturation" is used to describe the analogous property for systems consisting of a condensable phase other than water in a non-condensable phase other than air. [http://blowers.chee.arizona.edu/201project/GLsys.interrelatn.pg1.HTML]
The relative humidity of an air-water system is dependent not only on the temperature but also on the absolute pressure of the system of interest. This dependence is demonstrated by considering the air-water system shown below. The system is closed (i.e. no matter enters or leaves the system).
If the system at State A is isobariacally heated (heating with no change in system pressure) then the relative humidity of the system decreases because the saturated vapor pressure of water increases with increasing temperature. This is shown in State B.
If the system at State A is isothermally compressed (compressed with no change in system temperature) then the relative humidity of the system increases because the partial pressure of water in the system increases with increasing system pressure. This is shown in State C.
Therefore a change in relative humidity can be explained by a change in system temperature, a change in the absolute pressure of the system, or change in both of these system properties.
Other important facts
A gas in this context is referred to as saturated when the vapor pressure of water in the air is at the equilibrium vapor pressure for water vapor at the temperature of the gas and water vapor mixture; liquid water (and ice, at the appropriate temperature) will fail to lose mass through evaporation when exposed to saturated air. It may also correspond to the possibility of
dew orfog forming, within a space that lacks temperature differences among its portions, for instance in response to decreasing temperature. Fog consists of very minute droplets of liquid, primarily held aloft by isostatic motion (in other words, the droplets fall through the air at terminal velocity, but as they are very small, this terminal velocity is very small too, so it doesn't look to us like they are falling and they seem to be being held aloft).The statement that relative humidity (RH%) can never be above 100%, while a fairly good guide, is not absolutely accurate, without a more sophisticated definition of humidity than the one given here. An arguable exception is the
Wilson cloud chamber which uses, in nuclear physics experiments, an extremely brief state of "supersaturation " to accomplish its function.For a given
dewpoint and its correspondingabsolute humidity , the relative humidity will change inversely, albeit nonlinearly, with thetemperature . This is because the partial pressure of water increases with temperature – the operative principle behind everything fromhair dryer s todehumidifier s.Due to the increasing potential for a higher water vapor partial pressure at higher air temperatures, the water content of air at sea level can get as high as 3% by mass at 30 °C (86 °F) compared to no more than about 0.5% by mass at 0 °C (32 °F). This explains the low levels (in the absence of measures to add moisture) of humidity in heated structures during
winter , indicated by dryskin ,itch yeye s, and persistence of static electric charges. Even with saturation (100% relative humidity) outdoors, heating of infiltrated outside air that comes indoors raises its moisture capacity, which lowers relative humidity and increases evaporation rates from moist surfaces indoors (including human bodies.)Similarly, during summer in humid climates a great deal of liquid water condenses from air cooled in air conditioners. Warmer air is cooled below its dewpoint and the excess water vapor condenses. This phenomenon is the same as that which causes water droplets to form on the outside of a cup containing an ice-cold drink.
A useful rule of thumb is that the maximum
absolute humidity doubles for every 20 °F (11.1 °C) increase in temperature. Thus, the relative humidity will drop by a factor of 2 for each 20 °F (11.1 °C) increase in temperature, assuming conservation of absolute moisture. For example, in the range of normal temperatures, air at 70 °F (21.1 °C) and 50% relative humidity will become saturated if cooled to 50°F (10 °C), itsdewpoint and 40 °F (4.4 °C) air at 80% relative humidity warmed to 70 °F (21.1 °C) will have a relative humidity of only 29% and feel dry. By comparison, a relative humidity between 40% and 60% is considered healthy and comfortable in comfort controlled environments (ASHRAE Standard 55 - seethermal comfort ).Water vapor is a lighter gas than air at the same temperature, so humid air will tend to rise by natural
convection . This is a mechanism behindthunderstorms and otherweather phenomena. Relative humidity is often mentioned in weather forecasts and reports, as it is an indicator of the likelihood of precipitation, dew, or fog. In hotsummer weather , it also increases the apparent temperature tohuman s (and otheranimal s) by hindering theevaporation ofperspiration from the skin as the relative humidity rises. This effect is calculated as theheat index orhumidex .A device used to measure humidity is called a
hygrometer , one used to regulate it is called ahumidistat , or sometimeshygrostat . (These areanalogous to athermometer andthermostat for temperature, respectively.)References
* cite book
last = Himmelblau
first = David M.
authorlink =
title = Basic Principles And Calculations In Chemical Engineering
publisher =Prentice Hall
year = 1985454545
doi =
id = ISBN 0-13-066572-X
* cite book
last = Perry, R.H. and Green, D.W
first =
authorlink =
title =Perry's Chemical Engineers' Handbook (7th Edition)
publisher =McGraw-Hill
year = 1997
doi =
id = ISBN 0-07-049841-5See also
*
Humidity
*Absolute Humidity
*Specific Humidity
*Concentration
*Heat index
*Dew point
*Dew point depression
*Psychrometrics
*Humidity indicator
*Hygrometer External links
* [http://nsidc.org/arcticmet/glossary/psychrometric_tables.html Glossary definition of psychrometric tables] - National Snow and Ice Data Center
* [http://www.ems.psu.edu/~fraser/Bad/BadFAQ/BadCloudsFAQ.html Bad Clouds FAQ, PSU.edu]