Dose profile

Dose profile

In External Beam Radiotherapy, transverse and longitudinal dose measurements are taken by a radiation detector in order to characterise the radiation beams from medical linear accelerators. Typically, an ionisation chamber and water phantom are used to create these radiation dose profiles. Water is used due to its tissue equivalence.

Central Axis Dose profile for 15MV photon beam incident on water phantom. Here the linear accelerator collimation projects a 1x1 cm2 field at isocentre i.e. 100 cm SSD

Transverse dose measurements are performed in the x (crossplane) or y (inplane) directions perpendicular to the radiation beam, and at a given depth (z) in the phantom. These are known dose profiles. Dose measurements taken along the z direction create radiation dose distribution known as a depth-dose curve.

See also


Wikimedia Foundation. 2010.

Игры ⚽ Поможем сделать НИР

Look at other dictionaries:

  • Dose Profile — In External Beam Radiotherapy, transverse and longitudinal dose measurements are taken by a radiation detector in order to characterise the radiation beams from medical linear accelerators. Typically, an ionisation chamber and water phantom are… …   Wikipedia

  • Dose — means quantity in the following fields: In nutrition, medicine, and toxicology: Dose (biochemistry), the quantity of something that may be eaten by or administered to an organism, or that an organism may be exposed to Medicine and toxicology… …   Wikipedia

  • Percentage depth dose curve — In Radiotherapy, one of the dosimetry processes involves characterising the clinical radiation beam by measurement of the variation of dose with depth (z) in a water phantom, for all energies and field sizes.Dose is then normalised to dmax (the… …   Wikipedia

  • Radiation therapy — Radiation (medicine) redirects here. It is not to be confused with Radiation (pain) or Radiology. Radiation therapy Intervention ICD 10 PCS D ICD 9 CM …   Wikipedia

  • Particle therapy — Intervention ICD 9: 92.26 Particle therapy is a form of external beam radiotherapy using beams of energetic protons, neutrons, or positive ions for cancer treatment. The most common …   Wikipedia

  • Radiation burn — Classification and external resources ICD 9 990 …   Wikipedia

  • Radiosurgery — This article is about the medical procedure. For the album by American rock band New Found Glory, see Radiosurgery (album). Radiosurgery Intervention CLINAC: a model of steerable linear accelerator commonly used in radiosurgery …   Wikipedia

  • Fast neutron therapy — Intervention ICD 10 PCS D?0?5ZZ ICD 9: 92.26 Fast neutron therapy utilizes high energy neutrons typically greater than 20 MeV …   Wikipedia

  • Cyberknife — The CyberKnife is a frameless robotic radiosurgery system used for treating benign tumors, malignant tumors and other medical conditions.[1][2] The system was invented by John R. Adler, a Stanford University Professor of Neurosurgery and… …   Wikipedia

  • Megavoltage X-rays — Intervention ICD 9: 92.24 Megavoltage X rays are produced by linear accelerators ( linacs ) operating at voltages in excess of 1000 kV (1 MV) range, and therefore have an energy in the MeV ran …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”