- GE U50C
The GE U50C was a 5,000 hp (3,700 kW) diesel locomotive built by
GE Transportation Systems . They were twin-engined locomotives, combining two 2,500 hp (1,850 kW) diesel engines.Produced between November
1969 and November1971 solely for the Union Pacific; 40 locomotives were constructed. An evolution of the earlier U50 design, the U50C used a pair of three-axle trucks instead of the four two-axle trucks used on the U50. Again, these were reused trucks, this time from the later, 8500hp GE turbine locomotives.Development of the U50C was to the same UP specification that produced the
EMD DDA40X "Centennial" units—a requirement for a high power locomotive for the railroad's high-speed freight trains. The span-bolster B+B-B+B design was not suited to this service; furthermore, the requirement for power at speed rather than low-speed hauling meant that six powered axles would be sufficient.The design incorporated extensive weight saving features so as not to overload the three-axle trucks. GE replaced the 16-cylinder prime movers of the U50 with advanced 12-cylinder engines, which were lightweight and shorter. The engines were reversed in orientation compared to the U50, placing the radiator sections at the middle of the locomotive instead of the ends of the carbody. The shorter overall length required a wider radiator section design, similar to that used on the U33B and U33C locomotives.
The U50C was not a successful design. The extreme weight saving measures taken to make the locomotive able to use six axles rather than eight caused numerous problems, especially in the electrical wiring;
aluminum wires instead of the regularcopper had been used, which proved prone to overheating. The U50Cs suffered from many serious electrical fires as well as other failures; the UP rewired one unit with copper experimentally and considered having an outside contractor replace the wiring on all the units, but decided that the problems as a whole were too serious. The trucks suffered from stress cracks in the cast frames; the engines frequently developed low oil pressure; the cooling water leaked, and thedynamic brake grids were prone to melting down.A business downturn in
1976 proved the end of the U50C in service; all were withdrawn, although many were stored in serviceable condition. No return to service occurred, though five were lent out as stationary power generators during a coal miners' strike in early1978 . All were sold for scrap during 1977-1978.References
* Komanesky, John et al. " [http://www.thedieselshop.us/GE_U50.HTML General Electric U50 Roster] ". Retrieved
January 14 ,2005 .
* Percy, Richard A. " [http://espee.railfan.net/spu50.html Southern Pacific U50] ". RetrievedJanuary 14 ,2005 .
* Strack, Don. " [http://utahrails.net/up/diesels/up-diesel-story-1934-1982-d.php A History of Union Pacific Dieselization, 1934-1982, Part 4] ". RetrievedJanuary 14 ,2005 .
* Strack, Don. " [http://utahrails.net/all-time/all-time-index.php All-Time UP Diesel Roster] ". RetrievedJanuary 14 ,2005 .
* Strack, Don. " [http://utahrails.net/webpubs/up-dash8.php Union Pacific GE Dash 8 Locomotives] ". RetrievedJanuary 14 ,2005 . Mentions earlier UP GE purchases also.
*
Wikimedia Foundation. 2010.