- Intraocular pressure
Intraocular pressure (IOP) is the fluid
pressure inside theeye .Physiology and measurement
Intraocular pressure is mainly determined by the coupling of the production of
aqueous humor from the eye'sciliary body and its drainage through thetrabecular meshwork andSchlemm's canal located in theanterior chamber angle.Intraocular pressure is measured with a
tonometer .Influencing factors
Intraocular pressure measurement is also influenced by corneal thickness and rigidity. [Effect of Central Corneal Thickness on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Primary Open-angle Glaucoma by Matthias C. Grieshaber, MD; Andreas Schoetzau, MS; Claudia Zawinka, MD; Josef Flammer, MD; Selim Orgul, MD in Arch Ophthalmol. 2007;125:740-744.] [Corneal Pachymetry: A Prerequisite for Applanation Tonometry? by Tanaka in Arch Ophthalmol.1998; 116: 544-545]
ignificance
Ocular hypertension (OHT) is defined by intraocular pressure being higher than normal, in the absence ofoptic nerve damage orvisual field loss. [ [http://archopht.ama-assn.org/cgi/content/full/124/9/1251 Archives of Ophthalmology] ] [ [http://www.aoa.org/x1799.xml American Optometric Association] ] Current consensus inophthalmology defines normal intraocular pressure as that between 10mmHg and 20 mmHg. [ [http://www.webmd.com/hw/lab_tests/hw201323.asp webMD] ] [ [http://www.emedicinehealth.com/articles/14545-1.asp Glaucoma Overview] from eMedicine]The average value of intraocular pressure is 15.5 mmHg with fluctuations of about 2.75 mmHg. Intraocular pressure varies throughout the night and day. The diurnal variation for normal eyes is between 3 and 6 mmHg and the variation may increase in glaucomatous eyes. During the night, intraocular pressure usually decreases due to the slower production of aqueous humour. Intraocular pressure also varies with a number of other factors such as heart rate, respiration, exercise, fluid intake, systemic medication and topical drugs. Alcohol consumption leads to a transient decrease in intraocular pressure and caffeine may increase intraocular pressure. [Intraocular pressure measure on normal eyes by Pardianto G et al., in Mimbar Ilmiah Oftalmologi Indonesia.2005;2:78-9.]
An important quantitative relationship is provided below:IOP = F / C + PV Where, F = aqueous fluid formation rate,C= outflow rate,PV = episcleral venous pressure.The above factors are those that drive IOP. In the general population, IOP ranges between 10 and 21 mm Hg with a mean of about 15 or 16 mm Hg (plus or minus 3.5 mm Hg during a 24-hour cycle).
Ocular hypertension is the most important risk factor for
glaucoma .Differences in pressure between the two eyes is often clinically significant, and potentially associated with certain types of glaucoma, as well as
iritis orretinal detachment .Because of the effect of corneal thickness and rigidity on measured value of intraocular pressure, some forms of
refractive surgery (such asphotorefractive keratectomy ) can cause traditional intraocular pressure measurements to appear normal when in fact the pressure may be abnormally high.Intraocular pressure may become elevated due to anatomical problems,
inflammation of the eye, genetic factors, as a side-effect frommedication , or during exercise. [Intraocular Pressure Variation During Weight Lifting by Vieira et al., in Arch Ophthalmol.2006; 124: 1251-1254.] Intraocular pressure usually increases with age and is genetically influenced. [Intraocular pressure measure on normal eyes by Pardianto G et al., in Mimbar Ilmiah Oftalmologi Indonesia.2005;2: 80.] Hypotony, or ocular hypotony, is typically defined as intraocular pressure equal to or less than 5 mmHg. [ [http://www.emedicine.com/oph/topic579.htm eMedicine - Ocular Hypotony : Article by Sheila P Sanders ] ] [ [http://archopht.ama-assn.org/cgi/content/abstract/117/2/189 Arch Ophthalmol - Abstract: Elevated Intraocular Pressure and Hypotony Following Silicone Oil Retinal Tamponade for Complex Retinal Detachment: Incidence and Risk Factors, February 1999, Henderer et al. 117 (2): 189 ] ] Such low intraocular pressure could indicate fluid leakage and deflation of the eyeball.Case History
One of the most extensive intraocular pressure case history records assembled to date is available online. [ [http://fiteyes.com/blogs/dave/ fiteyes.com/blogs/dave] ] As of
December 29 ,2006 , this case history included over 12,755 intraocular pressure measurements over a period of 170 days under a wide variety of real life situations.Additional intraocular pressure measurements are continuing to be recorded at a rate of up to 100 per day and this case history web site is updated regularly. The size of the data set and the frequency with which measurements are recorded may lead to additional insights into intraocular pressure changes in response to a diverse number of factors. One interesting recent discussion that arose directly from data mining the large data set involved the timing of using glaucoma eye drop medications. [ [http://fiteyes.com/blogs/dave/2006/12/12/Interesting-Results-Of-Combining-Timoptic-and-Xalatan Combining-Timoptic-and-Xalatan] ]
Another question that is extensively discussed in the patient's commentary at the Case History site is the relationship between psychological stress and intraocular pressure. According to conventional wisdom, a patient's stress (e.g. nervousness or anxiousness) does not increase the patient's intraocular pressure the way it might increase their blood pressure. The data of the Case History challenges this convention wisdom, although a single case history will certainly not settle the question. What can be said at this point is that stress can seemingly increase intraocular pressure in at least the one individual being followed in this ambitious Case History project. Researchers will have to continue investigating the connection between stress and intraocular pressure.
References
External links
* [http://www.eyemdlink.com/Test.asp?TestID=16 EyeMDLink]
* [http://www.emedicinehealth.com/articles/37513-1.asp eMedicine]
* [http://www.opt.indiana.edu/riley/HomePage/NonContact/TEXT_Non_Contact.html Tonometry]
Wikimedia Foundation. 2010.